Symmons SWM-0153-2700-0.5, SWM-0153-2700-1.0, SWM-0153-2700-1.5, SWM-0153-2700-2.2 Installation guide

  • Hello! I'm your chat assistant, and I've reviewed the Symmons SWM-0153-2700-1.5 Lavatory Faucet Operation & Maintenance Manual. This document details the specifications, installation, operation, maintenance, and troubleshooting of the wall-mounted lavatory faucet. It includes key features like a ceramic cartridge and a 1.5 gpm flow regulator.. I'm ready to answer your questions about this product.
  • What flow regulator is included in the standard model?
    What material is the faucet made of?
    Is this faucet suitable for commercial installations?
    What is the warranty for consumer installations?
Model Number Specification
Dimensions
Warranty
Limited Lifetime - to the original end purchaser in
consumer installations.
5 Years - for commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Wall Mounted Lavatory Faucet
Operation & Maintenance Manual
SWM-0153-2700-1.5
Note: Dimensions subject to change without notice.
Note: Append appropriate -sufx to model number.
Modifications
-0.5 0.5 gpm (1.9 L/min) flow regulator
-1.0 1.0 gpm (3.8 L/min) flow regulator
-2.2 2.2 gpm (8.3 L/min) flow regulator
-G Grid drain
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
Compliance
-ASME A112.18.1/CSA B125.1
-NSF/ANSI 61.9, NSF/ANSI 372
-WaterSense 1.5 gpm (5.7 L/min)
SWM-0153-2700-1.5 Wall Mounted Lavatory Faucet Wall mounted lavatory faucet featuring two hole mounting
conguration. Includes ceramic cartridge and 1.5 gpm
(5.7 L/min) ow regulator. Components made from brass
and nonmetallic materials plated in standard polished
chrome nish.
Note: Requires hot and cold inlet piping to be reversed.
Measurements
AMin. 1-1/2", 38 mm
Max. 1-3/4", 44 mm
B Max. 3/4", 19 mm
C Min. 5-7/8", 149 mm
D
(2x) Hole Size
Min. Ø 2", 51 mm
Max. Ø 2-1/4", 57 mm
E 3-3/8", 86 mm
F 9", 229 mm
G 3-3/8", 86 mm
H 4", 102 mm
I (2x) 1-7/8", 48 mm
J 3-5/16", 84 mm
AA
BB
FINISHED WALLFINISHED WALL
BLOCKINGBLOCKING
DD
CC
EE
FF
GG
HH
JJ
II
Certied by
NSF International
2
Parts Breakdown
Replacement Parts
Item Description Part Number
A
F
G
Spout Assembly, 0.5 gpm
Spout Assembly, 1.0 gpm
Spout Assembly, 1.5 gpm
Spout Assembly, 2.2 gpm
RL-218-0.5
RL-218-1.0
RL-218-1.5
RL-218-2.2
F
G
Flow Regulator, 1.5 gpm
Flow Regulator, 0.5 gpm
Flow Regulator, 1.0 gpm
Flow Regulator, 2.2 gpm
RL-186
RL-186-0.5
RL-186-1.0
RL-186-2.2
H
IHandle Assembly RL-264
J
K
Escutcheon &
Mounting Ring RL-265
M
N
Temperature Limit Stop
Cartridge KN-4
B
A
F
G
I
H
J
K
L
N
M
WOOD BLOCKING
NOT INCLUDED
FINISHED WALL
D
E
C
Tools Required
Adjustable Wrench
Allen Wrench (1/8”)
Flat Head
ScrewDriver
Phillips Head
ScrewDriver
Plumber Tape
Rubber Mallet
Solder
Torch
3
Installation
1) If replacing an older faucet ensure water supply is turned OFF before removing, then turn faucet control valve
ON to relieve water pressure.
2) Water lines MUST be thoroughly ushed BEFORE and AFTER installing the faucet to prevent foreign matter
i.e. copper chips, sand, stones, etc. from clogging and damaging the sealing surfaces of the cartridge.
E
D
1) Secure valve body mount (E) to
wood blocking with (6x) wood
screws (D).
COLD
INLET
HOT
INLET
E
4) Install nished wall and remove
spout body plug (C) from spout
body on valve body mount (E).
5) Install mounting ring (J) ush to
nished wall. Attach handle (I) to
cartridge (N) and secure with set
screw (H).
6) Install spout escutcheon (B) ush
to nished wall. Install spout (A)
to spout body on valve body
mount (E).
C
E
FINISHED WALL
1
2
H
I
J
N
FINISHED WALL
3
1
A
2
FINISHED WALL
B
E
2) Pipe hot water supply to copper
tube inlet on right side of valve
body mount (E) and cold water
supply to copper tube inlet on left
side of valve body mount.
3) Install escutcheon (K) ush to valve
body on valve body mount (E).
K
E
4
Installation
7) Remove housing (G) and ow
regulator (F) from spout (A). Turn
on water supplies and ush
faucet free of debris.
Operation
9) Optional: Adjust limit stop
washer to limit handle turn to the
hot position if desirable.
1) Push faucet handle inward to turn
faucet on.
2) Turn counter-clockwise to put
faucet handle in the hot position.
3) Turn clockwise to put faucet handle
in the cold position.
1
F
G
A
2
1
3
1
3
LIMIT HOT
LIMIT COLD
8) Install ow regulator (F) and
housing (G) to spout (A).
1
2
F
G
A
ON
HOT COLD
Maintenance
1) Turn water supplies off. Remove
set screw (H), handle (I), mounting
ring (J) and escutcheon (K).
2) Use at head screwdriver
and rubber mallet to remove
compression nut (L).
3) Remove cartridge and inspect
for debris. Replace cartridge if
necessary.
3
2
H
I
4
J
K
1
L
4) Install cartridge following steps 1
and 2 in reverse.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2016 Symmons Industries, Inc. symmons.com [email protected] ZV-3186 REV C 102416
Troubleshooting Chart
Troubleshooting Chart
Faucet no longer maintains
accurate temperature.
Foreign matter such as copper chips,
sand, stones, etc. clogging the
cartridge ports and/or damaging the
sealing surfaces of the cartridge.
Remove cartridge (N) and inspect for
debris. Replace cartridge if necessary.
Faucet leaks from handle. Same as above. Same as above.
Handle is loose. Set screw has loosened. Tighten set screw (H).
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
/