Door/WindowSensor
UserManual
Description
Thisproductisaseparatetriggerdetectorequipswithmagnetandmagneticsensorandwirelesstransmitfunctionality.Whenthe
magnetandthemagneticsensorisseparated,theproductissuewirelessalarmsignaltotheassociatedgateway.Itissuitablefora
varietyofinstallationenvironmentrequirements,withdoorsandwindowsopen,closetherealtimedetectionandcovertamper,
batterylevelstatusreportfunction.
TheproductisZWaveplusdevicewhichiswirelessaccessibleandcanquickly,easilyincludedandoperatedinanyZWavenetwork
withotherZWavecertifieddevicesfromanyothermanufacturers.
Installation
Note:Thisproductshouldnotbeinstalledinthefollowingplacesmakesureproduct
workingnormally.
i. Shouldnotinstallintheoutdoorwhereeasytodamagethelocation;
ii. Shouldnotinstallinthefoundationisnotstrongorrainyposition;
iii. Shouldnotinstallintheplaceclosetopowersupplylinesormagneticfield.
Installprepare:
Removethebatteryplasticseparatorbeforeinstalltheproductonthewall.(referto
figurebeside)
BatterylevelstatusandReplacement
LowbatterylevelwaswarningwhileLEDflashquickly,pleasereplacenewbatteryassoonaspossible.
Openthebottomcoverwithasmallscrewattheplasticseparatorhole,takeoutthePCBAtoreplacethebattery.
Pleasebenoted,thesametypeofbatteryisrecommendedmakesurebatteryusinglife.
ZWaveNetworkSetup
AddintoZWavenetwork
1) Removethebatteryplasticseparatorormakesurebatterylevelis
normally,andMakesuretheproductislocatedwithindirectrange
oftheZWavecontroller.
2) Setthemaincontrollerintotheinclusion/Adddevicemode(refer
tomaincontroller’soperatingmanual).
3) ClicktheAdd/Removebuttononthebottomsideofproducttriple
timesin1.5seconds.
4) TheproductwillbedetectedandincludedintheZWavenetwork.
[Note:] Duringinclusion,LEDwillfastflashredlightuntilinclusionprocesscomplete,normallyitwillstayininclusionprocess
around60secondsiftherenotanycontrollerwasdetected.LEDwilllighton3secondnoticeinclusionissuccessful.After
inclusionsuccessful,theproductionwillbestayinwakeupfor30secondinordertoreceiveinitialwakeupconfiguration
fromthemaincontroller.
RemovefromZWavenetwork
1) MakesurebatterylevelisnormallyandtheproductislocatedwithindirectrangeoftheZWavecontroller.
2) Setthemaincontrollerintotheexclusion/Removedevicemode(refertomaincontroller’soperatingmanual).
3) ClicktheAdd/Removebuttononthebottomsideofproducttripletimesin1.5seconds.
4) TheproductwillbedetectedandexcludedfromtheZWavenetwork.
[Note:] Duringexclusion,LEDwillfastflashredlightuntilexclusionprocesscomplete,normallyitwillstayinexclusionprocess
around5secondsiftherenotanycontrollerwasdetected.LEDwilllighton3secondnoticeexclusionissuccessful.
Associationreportandcontrol
AssociationallowsfordirectcommunicationbetweenZWavenetworkdevices.Maincontrollerdoesnottakepartinsuch
communication.UsingthismechanismtheproductcouldreportsensorlifelinestatustoanotherZWavenetworkdevice,e.g.a
MasterController.
Theproductsupports10associationgroups.Eachgroup(#2~#10)supportsassociated5devicesmaximumexceptgroup#1supports
associatedonedeviceonly.Pleaserefertothemastercontroller’soperatingmanualtoaddanassociationdeviceandspecifyto
whichgroupandwhatdevicesaretobeassociated.
Group#1isassignedtosendunsolicitedreportofmagnetopen/closedetectionstatusandtampercoverstatus,batteryleveltothe
associateddeviceassoonwhilethestatusischange.
Group#2assignedtosendNotificationreporttootherdevicewhilethesensordetecteddooropen/close.
Group#3assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethesensordetecteddooropen.
Group#4assignedtosendBasicSetOffCommandtocontrolotherdevicewhilethesensordetecteddooropen.
Group#5assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethesensordetecteddoorclose.
Group#6assignedtosendBasicSetOffCommandtocontrolotherdevicewhilethesensordetecteddoorclose.
Group#7assignedtosendNotificationreporttootherdevicewhilethetamperdetectedon/off.
Group#8assignedtosendBinarysensorreporttootherdevicewhilethetamperdetectedon/off.
Group#9assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethetamperdetectedopen.
Group#10assignedtosendBasicSetOffCommandtocontrolotherdevicewhilethetamperdetectedopen.
WakeuptheproductmanuallyforZWaveconfiguration
Theproductisinbatterypower,youcansetupthewakeuptimebasedinseconds.Ateachwakeup,theproductcommunicates
withthemastercontrollertoupdatesparameterssettingsifnecessary,e.g.receivetheassociationgroupsetting.Theproductwill
wakeupatdefinedtimeintervalandwillALWAYStrytocommunicatewiththemastercontroller.Longertimeintervalmeansless
frequentcommunicationandthusalongerbatterylife.
Theproductdefaultwakeupintervalis86400seconds.Usercanoperateinclusion/exclusionprocessinordertotriggerproduct
wakeupmanually,itwillkeeps30secondsinwakeupstatewithoutinitialwakeupparametersettingandkeeps10secondsin
wakeupafterinitialwakeupparameter.
ApplicationRequirementReject
TheNotificationReportscannotbedeactivated. ApplicationRejectedRequestwithstatus0x00occurswhenthecontrollertriesto
deactivate/turnofftheNotificationTypeinordertonottriggerthespecificNotificationReportagain.
NotificationTypesandEvents
Theproductsupportsnotificationalarmtypeof“ACCESS_CONTROL=0x06”andeventtypeof
“EVENT_ACCESS_CONTROL_DOOR_IS_OPEN=0x16”and“EVENT_ACCESS_CONTROL_DOOR_IS_CLOSE=0x17”whiledooropenor
close.
Theproductsupportsnotificationalarmtypeof“HOME_SECURITY=0x07”andeventtypeof
“EVENT_HOME_SECURITY_TAMPERING_COVERING_REMOVED=0x03”and“NO_EVENT=0x00”whiledetecttamperonoroff.
BinarySensorReport
Theproductsupportsbinarysensorreportvalueof“DETECTANEVENT=0xFF”and“IDLE=0x00”whiledetecttamperonoroff.
OTAfirmwareupdate
TheproductsupportsupdatefirmwarebyOTA.ItisstrongrecommendreplacewithnewbrandbatterybeforestartOTAfirmware
updateinordertomakesurepowersupplyduringOTAfirmwareupdateprocessing.
DefaultFactoryReset
Thefactorydefaultsettingsarerestoredwhenthedeviceisremovedfromthenetwork.Pleaseusethisprocedureonlywhenthe
networkprimarycontrollerismissingorotherwiseinoperable.
TechnicalParameters
Operatingvoltage: 3V(BatteryType:CR2450)
Quiescentcurrent: 4uA
Alarmcurrent: 20mA
Thealarmprompt:LEDflashes
868.42MHzChina/Europe
Operatingfrequency
908.42MHzUnitedStates
921.42MHzAustralia
869.22MHzRussia
fromtheindoordistanceof30meters
Thedistance
Outdoorstraightdistanceof40meters
Operatingtemperature:10℃~+50
Relativehumidity≤95RH
36x78x19mm(doormountmodule)
Dimensions
15x78x19mm(magnetassembly)
ImplementationofthestandardGB152092006
ZWaveParameters
DeviceType:
GenericDeiceType=GENERIC_TYPE_SENSOR_NOTIFICATION
SpecificDeviceType=SPECIFIC_TYPE_NOTIFICATION_SENSOR
ZWavePlusRoleType:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPORTING
SupportCommandClass:
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_WAKE_UP,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_FIRMWARE_UPDATE_MD,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_BATTERY,
COMMAND_CLASS_NOTIFICATION,
COMMAND_CLASS_SENSOR_BINARY,
COMMAND_CLASS_APPLICATION_STATUS,
/