Z‐WaveNetworkSetup
AddintoZ‐Wavenetwork
1) Removethebatteryplasticseparatorormakesurebatterylevelis
normally,andMakesuretheproductislocatedwithindirectrange
oftheZ‐Wavecontroller.
2) Setthemaincontrollerintotheinclusion/Adddevicemode(refer
tomaincontroller’soperatingmanual).
3) ClicktheAdd/Removebuttononthebottomsideofproducttriple
timesin1.5seconds.
4) TheproductwillbedetectedandincludedintheZ‐Wavenetwork.
[Note:] Duringinclusion,LEDwillfastflashredlightuntilinclusionprocesscomplete,normallyitwillstayininclusionprocess
around60secondsiftherenotanycontrollerwasdetected.LEDwilllighton3secondnoticeinclusionissuccessful.After
inclusionsuccessful,theproductionwillbestayinwakeupfor30secondinordertoreceiveinitialwakeupconfiguration
fromthemaincontroller.
RemovefromZ‐Wavenetwork
1) MakesurebatterylevelisnormallyandtheproductislocatedwithindirectrangeoftheZ‐Wavecontroller.
2) Setthemaincontrollerintotheexclusion/Removedevicemode(refertomaincontroller’soperatingmanual).
3) ClicktheAdd/Removebuttononthebottomsideofproducttripletimesin1.5seconds.
4) TheproductwillbedetectedandexcludedfromtheZ‐Wavenetwork.
[Note:] Duringexclusion,LEDwillfastflashredlightuntilexclusionprocesscomplete,normallyitwillstayinexclusionprocess
around5secondsiftherenotanycontrollerwasdetected.LEDwilllighton3secondnoticeexclusionissuccessful.
Associationreportandcontrol
AssociationallowsfordirectcommunicationbetweenZ‐Wavenetworkdevices.Maincontrollerdoesnottakepartinsuch
communication.UsingthismechanismtheproductcouldreportsensorlifelinestatustoanotherZ‐Wavenetworkdevice,e.g.a
MasterController.
Theproductsupports10associationgroups.Eachgroup(#2~#10)supportsassociated5devicesmaximumexceptgroup#1supports
associatedonedeviceonly.Pleaserefertothemastercontroller’soperatingmanualtoaddanassociationdeviceandspecifyto
whichgroupandwhatdevicesaretobeassociated.
Group#1isassignedtosendunsolicitedreportofmagnetopen/closedetectionstatusandtampercoverstatus,batteryleveltothe
associateddeviceassoonwhilethestatusischange.
Group#2assignedtosendNotificationreporttootherdevicewhilethesensordetecteddooropen/close.
Group#3assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethesensordetecteddooropen.
Group#4assignedtosendBasicSetOffCommandtocontrolotherdevicewhilethesensordetecteddooropen.
Group#5assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethesensordetecteddoorclose.
Group#6assignedtosendBasicSetOffCommandtocontrolotherdevicewhilethesensordetecteddoorclose.
Group#7assignedtosendNotificationreporttootherdevicewhilethetamperdetectedon/off.
Group#8assignedtosendBinarysensorreporttootherdevicewhilethetamperdetectedon/off.
Group#9assignedtosendBasicSetOnCommandtocontrolotherdevicewhilethetamperdetectedopen.