Thermo Manufacturing 44002 Installation guide

  • Hello! I've reviewed the Installation Instructions for the ThermoThimble Line Set Kit. This document details the process for creating an air-tight seal for through-the-wall installations, highlighting features like its adjustable flange, half-brick size, and suitability for retrofits. I'm here to assist you with any questions you have about the installation or the product.
  • What does the ThermoThimble do?
    Can it be used for retrofits?
    Does the kit have a temporary plug?
    What size is the ThermoThimble?
    Can it be installed vertically?
ThermoThimble is innovative…
• Creates a permanent, air-tight seal
through walls.
• Temporary plug keeps out air,
insects and other pests.
• For new construction or retrofit.
• No ugly line holes to patch.
ThermoThimble is easy to install…
• Half-brick size!
• Adjustable flange lends a clean,
professional look.
• Install vertical or horizontal on
siding or masonry walls.
• Flange pre-marked for nails or
screws.
Add a professional look to
through-the-wall installations!
THERM THIMBLE
O
THROUGH-THE-WALL LINE SET KIT
Cut hole in siding only, do not cut through
interior surface.
2
4Place outer flange and tube into wall.
5Screw outer flange in four corners and caulk
around siding to form weather-tight seal.
Determine location for line set and place
outer 1” flanged tube assembly against
exterior wall surface and mark where hole is to be
cut. Thimble may be installed vertical or
horizontal. Fig. A.
Place tube in the center of the siding hole,
mark and cut hole 1/4” larger than tube size.
Fig. B. Cut matching hole on inside wall.
3
Place line set through tube and seal both
ends with foam insulation supplied. Fig. D.
7
7A. Place interior flange over tube and screw
flange in four corners, providing interior surface
is other than brick or block. Caulk all edges. If
interior surface is brick or block, simply calk
with Liquid Nails® as a final step.
NOTE:
For brick or block installation follow steps1-4
above, then continue below:
5A. Caulk the inside of the outer flange with
Liquid Nails®.
Optional: If needed for extra hole coverage,
place the large cover plate provided behind the
interior flange. Fig. E.
Place interior flange onto tube and screw
four corners as shown in Fig. C. ( Tube may
be vinyl taped to interior flange in place of screws).
6
US & CANADA TOLL FREE PHONE
888-678-3709
US & CANADA TOLL FREE FAX
888-678-8711
www.ThermoPan.com
THERMO MANUFACTURING INC.
A
B
C
D
E
S
A
V
E
S
T
I
M
E
S
A
V
E
S
L
A
B
O
R
S
A
V
E
S
M
O
N
E
Y
M
O
R
E
P
R
O
F
E
S
S
I
O
N
A
L
THE
ADVANTAGE
1
INSTALLATION INSTRUCTIONS
7 02070 44008 2
/