EMKO ERM-3770 User manual

Type
User manual

EMKO ERM-3770 is an advanced digital tachometer with a wide range of capabilities designed to measure period and frequency in various industrial applications. It offers a 77x35 DIN size panel-mount design for easy integration into control systems. With its NPN or PNP input type, it can interface with different types of sensors, such as proximity sensors, switches, and optic sensors.

EMKO ERM-3770 is an advanced digital tachometer with a wide range of capabilities designed to measure period and frequency in various industrial applications. It offers a 77x35 DIN size panel-mount design for easy integration into control systems. With its NPN or PNP input type, it can interface with different types of sensors, such as proximity sensors, switches, and optic sensors.

ERM-377077x35DINSizeDigitalTachometer
-4DigitsDisplay
- Adjustabledecimalpoint
-Divisionrate
-NPNorPNP inputtype
-WorkingwithProcessSetand AlarmSetvalue
- Alarmoutput
RelayorSSRdriveroutput(Itmustbedeterminedinorder.)
- AlarmSetvalueboundary
-0,07Hzto10000Hzinputsignal
- Automaticsampling(1sec.to16sec.)
-Programmingmodepasswordprotection
ERM-377077x35DINSize
DigitalTachometer
InstructionManual.ENGERM-377002V0409/14
2
ABOUTINSTRUCTIONMANUAL
Instruction manual of ERM-3770 Digital Tachometer consists of two main sections.
Explanation of these sections are below. Also, there are other sections which include order
information and technical specifications of the device. All titles and page numbers in instruction
manual are in “ ” section. User can reach to any title with section number.
In this section, physical dimensions of the device, panel mounting, electrical wiring,
physical and electrical installation of the device to the system are explained.
Also in these sections, there are warnings to prevent serious injury while doing the
physical and electrical mounting or using the device.
Explanation of the symbols which are used in these sections are given below.
CONTENTS
Installation:
Operation and Parameters:
In this section user interface of the device, accessing to the parameters, description of the
parameters are explained.
a
c
i
This symbol is used to determine the dangerous situations as a result of an electric
shock. User must pay attention to these warnings definitely.
This symbol is used for safety warnings. User must pay attention to these
warnings.
This symbol is used to determine the important notes about functions and usage of
the device.
1.PREFACE...........................................................................................................................................
2.INSTALLATION...................................................................................................................................
3.ELECTRICAL WIRING.......................................................................................................................
1.1GENERAL SPECIFICATIONS
1.2ORDERINGINFORMATION
2.1GENERAL DESCRIPTION
2.4PANEL CUT-OUT
2.5ENVIRONMENTAL RATINGS
2.6PANEL MOUNTING
2.7INSTALLATIONFIXINGCLAMP
2.8REMOVINGFROM THEPANEL
3.1 TERMINAL LAYOUT ANDCONNECTIONINSTRUCTIONS
3.4SUPPLY VOLTAGEINPUT CONNECTIONOF THEDEVICE
3.7 ALARMOUTPUT CONNECTIONS
3.7.1RELAY OUTPUT CONNECTION
1.3WARRANTY
1.4MAINTENANCE
2.2FRONT VIEW ANDDIMENSIONSOFERM-3770DIGITAL TACHOMETERWITH ALARM
OUTPUT
2.3FRONT VIEW ANDDIMENSIONSOFERM-3770DIGITAL TACHOMETERWITHOUT
ALARMOUTPUT
3.2ELECTRICAL WIRINGDIAGRAM
3.3VIEWOF THEDEVICELABEL
3.5PROCESSINPUT CONNECTION
3.5.1PROXIMITY CONNECTION
3.5.2SWITCHCONNECTION
3.6GALVANICISOLATION TEST VALUESOFERM-3770DIGITAL TACHOMETER
3.7.2SSRDRIVEROUTPUT CONNECTION
4.1FRONT PANEL DEFINITIONOFERM-3770DIGITAL TACHOMETERWITH ALARM
OUTPUT
4.2FRONT PANEL DEFINITIONOFERM-3770DIGITAL TACHOMETERWITHOUT ALARM
OUTPUT
4.3OBSERVATIONOF THESOFTWAREREVISIONON THEDISPLAY
4.4CHANGING ANDSAVINGPROCESSSET VALUE
4.5PROGRAMMINGMODEPARAMETERLIST
4.6OPERATIONGRAPHICSOF ALARMOUTPUT AND ALARM TYPES
4.7EASY ACCESSINGDIAGRAMOFPROGRAMMINGMODEPARAMETERS
4.7.1DEVICEWITH ALARMOUTPUT
4.7.2DEVICEWITHOUT ALARMOUTPUT
4.8ENTERING TO THEPROGRAMMINGMODE,CHANGING ANDSAVINGPARAMETERS
4.FRONTPANEL DEFINITION AND ACCESSINGTOTHEMENUS...................................................
5.FAILUREMESSAGESINERM3770DIGITAL TACHOMETER........................................................
6.SPECIFICATIONS...............................................................................................................................
6.OTHERINFORMATIONS....................................................................................................................
Contents
Page5
Page19
Page12
Page7
Page 30
3
Page 29
Page 30
4
ManufacturerCompanyName :
ManufacturerCompany Address:
EmkoElektronik A.S.
DOSAB,KaranfilSokak,No:6,16369Bursa, Turkiye
EUDECLARATIONOFCONFORMITY
Themanufacturerherebydeclaresthattheproductconformstothefollowingstandardsand
conditions.
ERM-3770
ERM-3770
Electricalequipmentformeasurement,controlandlaboratory
use
ProductName
ModelNumber :
TypeNumber :
ProductCategory :
Conformstothefollowingdirectives:
:Digital Tachometer
73/23/EEC TheLowVoltageDirectiveasamendedby93/68/EEC
89/336/EEC TheElectromagneticCompatibilityDirective
EN61000-6-4:2007EMCGenericEmissionStandardfortheIndustrialEnvironments
EN61000-6-2:2005EMCGenericImmunityStandardfortheIndustrialEnvironments
EN61010-1:2001 SafetyRequirementsforelectricalequipmentformeasurement,control
Andlaboratoryuse
16 October2009 Name :Serpil YAKIN
Bursa-TURKEY Position :QualityManager
Hasbeendesignedandmanufacturedtothefollowingspecifications:
WhenandWhereIssued AuthorizedSignature
th
1.Preface
1.1GeneralSpecifications
ERM-3770 series Digital Tachometers are design for measuring the period in Industry. They can
be used in many applications with their easy use, alarm output, universal process input
properties. You can easily adapt them to automation systems and mechanical process.
Some application fields which they are used are below:
Glass
Plastic
Petro-Chemistry
Automotive, Textile
MachineProductionIndustries
etc.
Periodmeasurement
Frequencymeasurement
BandSpeedmeasurement
Linearorcircularmovement
InstantaneousFlowrate
Application Fields
Applications
5
ERM-3770
Optional
PowerSupply
Input
AlarmOutput
(SSRDriverOutput)
ProcessInput
AlarmOutput
Standard
230 V (±%15),50/60HzV
OptionalPowerSupply
115 V (±%15),50/60HzV
24V (±%15),50/60HzV
W24V (-%15;+%10)50/60Hz
Optional
AlarmOutput
(RelayOutput)
Switch
ProximitySensor
(NPN,PNP)
OpticSensor
1.2OrderingInformation
6
1.3Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts from
the delivery date. This warranty is in force if duty and responsibilities which are determined in
warranty document and instruction manual performs by the customer completely.
1.4Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device
before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl
alcohol or water to clean the external plastic case.
All order information of ERM-3770
Digital Tachometer are given on the table at
left. User may form appropriate device
configuration from information and codes
that at the table and convert it to the
ordering codes.
Firstly, supply voltage then other
specifications must be determined. Please
fill the order code blanks according to your
needs.
Please contact us, if your needs are
out of the standards.
V
Z
Vac,
Vdc can be applied.
Þ
Þ
c
OrderInformation
A BC D E FG HI /
/
UV W Z/
/
0 00 0 0 0
ERM-3770 (77x35DINSize)
324V ( %15)50/60HzV±
4115V ( %15)50/60HzV±
5230V ( %15)50/60HzV±
PowerSupply
A
1
AlarmOutput
E
0None
9Customer
00 00 0
SSRDriverOutput(Maximum28mA,15V )Z
2
RelayOutput(ResistiveLoad5A@250V ,1NO+1NC)V
224V (-%15;+%10)50/60HzW
7
In package ,
- One piece unit
- Two pieces mounting clamps
- One piece instruction manual
A visual inspection of this product for possible damage occured during shipment is
recommended before installation. It is your responsibility to ensure that qualified
mechanical and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power
off the system and the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch
and fuse as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to
prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble
with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may
results in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During the equipment is putted in hole on the metal panel while mechanical installation
some metal burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the
montage of the device with inappropriate fixing clamp. Be sure that device will not fall
while doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this
instruction manual.
separate
Before beginning installation of this product, please read the instruction
manual and warnings below carefully.
2.Installation
c
2.1GeneralDescription
2.2FrontViewandDimensionsofERM-3770DigitalTachometerWith AlarmOutput
MountingClamp
FrontPanel
IP65protection
NEMA 4X
Panelsurface
(maximumthickness15mm/0.59inch)
8
Maximum15 0.59inchmm/
58.5mm/2.30inch4mm/0.16inch
35mm/1.38inch
77mm/3.03inch
DigitalTachometer
SET
ERM-3770
P
OP
SIG
SV
2.4PanelCut-Out
110mm/4.33inch(min)
50mm/1.97inch(min)
29mm/1.14inch
71mm/2.79inch
9
2.3FrontViewandDimensionsofERM-3770DigitalTachometerWithout AlarmOutput
Maximum15 0.59inchmm/
58.5mm/2.30inch4mm/0.16inch
35mm/1.38inch
77mm/3.03inch
DigitalTachometer
P
ERM-3770
P
SIG
10
c
OperatingTemperature:
Max.OperatingHumidity :
Altitude :
0to50°C
90 Rh(non-condensing)
Upto2000m.
%
OperatingConditions
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
2.5EnvironmentalRatings
c
2.6PanelMounting
1-Before mounting the device in your
panel, make sure that the cut-out is the
right size.
2-Insert the device through the cut-out.
If the mounting clamps are on the unit,
put out them before inserting the unit to
the panel.
During installation into a metal panel, care should be taken to avoid injury from
metal burrs which might be present. The equipment can loosen from vibration
and become dislodged if installation parts are not properly tightened. These
precautions for the safety of the person who does the panel mounting.
1
2
11
2.7InstallationFixingClamp
1-Pull mounting clamps from left and
right fixing sockets.
2-Pull the unit through the front side of
the panel
The unit is designed for panel
mounting.
1-Insert the unit in the panel cut-out
from the front side.
2- Insert the mounting clamps to the
fixing sockets that located left and
right sides of device and make the unit
completely immobile within the panel
Before starting to remove the unit from panel, power off the unit and the related
system.
Montage of the unit to a system must be done with it’s own fixing clamps. Do not
do the montage of the device with inappropriate fixing clamps. Be sure that
device will not fall while doing the montage.
2.8Removingfromthepanel
c
c
2
1
1
2
1 2 3 4 5 6 7 8 9 10 11 12
12
a
3.1TerminalLayoutandConnectionInstructions
3.ElectricalWiring
c
c
c
c
You must ensure that the device is correctly configured for your application.
Incorrect configuration could result in damage to the process being controlled,
and/or personal injury. It is your responsibility, as the installer, to ensure that
the configuration is correct.
Device parameters has factory default values. These parameters must be set
according to the system’s needs.
Only qualified personnel and technicians should work on this equipment. This
equipment contains internal circuits with voltage dangerous to human life.
There is severe danger for human life in the case of unauthorized intervention.
Be sure to use the rated power supply voltage to protect the unit against
damage and to prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and
trouble with the unit can be prevented.
Torque
0,5Nm
Max.2.5mm/0.098inch
WireSize:
14 AWG/1mm²
Solid/Stranded
Screwdriver
0,8x3mm
13
NOTE-1: The output exist in device withAlarm Output.
i
3.2ElectricalWiringDiagram
Electrical wiring of the device must be the same as ‘Electrical Wiring Diagram’
below to prevent damage to the process being controlled and personnel injury.
c
a
P/N: 770ERM-3
Yc
OUTPUT
NO NCC
5A@250V V
1 2 3 4 5 6 7 8 9 10 11 12
PowerSupplyInput
(Itmustbedeterminedinorder.)
230 VA
115 VA
VA
V (±%15)50/60Hz-1.5
V (±%15)50/60Hz-1.5
24V (±%15)50/60Hz-1.5
24V (-%15;+%10)50/60Hz
V
V
V
W
L N
RelayorSSR
DriverModuleOutput SensorSupplyVoltage
12V
Max.30mA
Z(±35%)
0V Z
ProcessInput
(+) (-)
SSROutput
NOTE-1
3.3ViewoftheDeviceLabel
14
DeviceLabelforUniversalProcessInput,230V SupplyVoltageInput
andRelayOutput
V
DeviceLabelforUniversalProcessInput,230V SupplyVoltageInputWithout Alarm
Output
V
2
Y
c
a
LN
OUTPUT
230 V ±15%
50/60Hz -1.5VA
V
341 5
NO NCC
5 A@250V V
6 7 8 9 10 11 12
12V %35
max.30mA
Z±
0VZ
Input
(0,07Hz - 10kHz)
P/N:ERM-3770-5.00.0.1/00.00/0.0.0.0
2
Y
c
a
LN
230 V ±15%
50/60Hz -1.5VA
V
341 56 7 8 9 10 11 12
0VZ
12V %35
max.30mA
Z±
P/N:ERM-3770-5.00.0.0/00.00/0.0.0.0
Input
(0,07Hz - 10kHz)
15
3.4SupplyVoltageInputConnectionoftheDevice
Supply voltage range must be determined in order. Device is produced
different for low and high voltage. While installing the unit, supply voltage
range must be controlled and appropriate supply voltage must be applied to
the unit. Controlling prevents damages in unit and system and possible
accidents as a result of incorrect supply voltage.
There is no power supply switch or fuse on the device. So the user must put
power supply switch and a fuse to the supply voltage input. In accordance
with the safety regulations, the power supply switch shall bring the
identification of the relevant instrument. Power supply switch and fuse must
be put to a place where user can reach easily.
c
Power supply switch must be two poled for seperating phase and neutral.
On/Off condition of power supply switch is very important in electrical
connection. On/Off condition of power supply switch must be signed for
preventing the wrong connection.
External fuse must be on phase connection in supply input.V
c
c
Make sure that the power supply voltage is the same indicated on the
instrument.
Switch on the power supply only after that all the electrical connections have
been completed.
c
PowerSupplyInputConnection
4
NL
5
Power
Supply
Switch
c
a
External
Fuse
(1 A T)
SupplyVoltage
230V (±%15)50/60Hzor
115V (±%15)50/60Hzor
24V (±%15)50/60Hzor
24V (-%15;+%10)50/60Hz
V
V
V
W
Y
Note-1
Note-1:ExternalFuseisrecommended.
3.5.1ProximityConnection
3.5ProcessInputConnection
16
10 12 11
12V
Max.30mA
Z
0V Z
Input
PROX.
PNP
PNP typeoperation
=
10 12 11
12V
Max.30mA
Z
0V Z
Input
PROX.
NPN
NPNtypeoperation
=
Sensor Supply Voltage is 12 V %35 maximum 30 mA.Z±
i
3.5.2SwitchConnection
10 12 11
Input
Switch
0V Z
12V
Max.30mA
Z
=
10 12 11
Input
Switch
0V Z
12V
Max.30mA
Z
=
PNP typeoperation NPNtypeoperation
17
3.6GalvanicIsolationTestValuesof 77ERM-3 0 DigitalTachometer
PowerSupply 4
5Ground 12
2000V V
2000V V
2000V V
2000V V
2000 ( ERM-3770 )V for .5
5
V
00V (forERM-377 .3)V0
1
2
AlarmOutput
SSRDriverOutput
1
2
1
2
Alarm Output
RelayOutput
Process
Input 1111
3
1
2
3
2000V V
VoltageOutput
12V Z1010
18
3.7.2SSRDriverOutputConnection
Fuse
Load
LastControl
Element
(SSR)
2
Device L N
1
Fuses must be selected according to the application.
c
c
Max.15V
Max.28mA
Z
3.7 AlarmOutputConnections
Fuses must be selected according to the application.
c
Device
1Load
L N
2
Max
5 A TFuseV
NC
C
NO
3.7.1RelayOutputConnection
3c
DigitalTachometer
SET
ERM-3770
P
OP
SIG
SV
DisplayProcessValue,
ProcessSetValueand
Parameters
Itisusedtoenterto
theProcessSetValue
ChangingMode,
ProgrammingMode
andusedasEnter
button
Itisusedtoincreasethe
valueinProcessSet
ValueChangingMode
andProgrammingMode.
Alsoinprogramming
modeItisusedtoaccess
totheparametervalues.
Itisusedtodecrease
thevalueand Alarm
CancellingButton
Note-1
Note-1
4.FrontPanelDefinitionand AccessingtotheMenus
AlarmOutput
ActiveLed
LedIndicationofProcessSetValue
ChangingModeis Active
LedIndicationofProgramming
Modeis Active
SignalLed
19
4.2FrontPanelDefinitionofERM-3770DigitalTachometerWithout AlarmOutput
4.1FrontPanelDefinitionofERM-3770DigitalTachometerWith AlarmOutput
Note-1: If increment or decrement button is pressed for 5 seconds continuously, increment and
decrement number become 10, if increment or decrement button is pressed for 10 seconds
continuously, increment and decrement number become 100, if increment or decrement button
is pressed for 15 seconds continuously, increment and decrement number become 1000.
DigitalTachometer
P
ERM-3770
P
SIG
DisplayProcessValue
andParameters
Itisusedtoenterto
theProgramming
Modeandusedas
Enterbutton
Itisusedtoincreasethe
valueinProgramming
Mode. Alsoin
programmingmodeItis
usedtoaccesstothe
parametervalues.
Itisusedtodecrease
thevalue.
Note-1
Note-1
LedIndicationofProgramming
Modeis Active
SignalLed
20
MainOperationScreen ProcessSetValueScreen
Changetheprocesssetvalue
withincrementanddecrement
buttons.
PressSET buttonforsavingthe
processsetvalue
SVledlightsoffandmainoperation
screenisshown.
If no operation is performed in Process set value changing mode for 20 seconds,
device turns to main operation screen automatically.
i
4.4ChangingandSavingProcessSetValue
MainOperationScreen
ProcessSetValueScreen
WhenSET buttonispressed,SVLED
lightsonandprocesssetvalueis
shownonthedisplay.
SET
P
OP
SIG
SV
SET
P
OP
SIG
SV
SET
P
OP
SIG
SV
SET
P
OP
SIG
SV
Process Set Value changing mode is active, when the device exist Alarm output.
i
When power is first applied to the digital process indicator, software revision number is shown on
the display.
4.3ObservationofSoftwareRevisionontheDisplay
Software
revision
number
MainOperationScreenisshown
“rv” RevisionÞDigitalTachometer
SET
ERM-3770
P
OP
SIG
SV
DigitalTachometer
SET
ERM-3770
P
OP
SIG
SV
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

EMKO ERM-3770 User manual

Type
User manual

EMKO ERM-3770 is an advanced digital tachometer with a wide range of capabilities designed to measure period and frequency in various industrial applications. It offers a 77x35 DIN size panel-mount design for easy integration into control systems. With its NPN or PNP input type, it can interface with different types of sensors, such as proximity sensors, switches, and optic sensors.

Ask a question and I''ll find the answer in the document