GNATUS Consola Syncrus GL FO Owner's manual

Category
Power heat guns
Type
Owner's manual
2
ÍNDICE / INDEX
EnglishEspañol
Product Description ...............................................................................................................03
Warranty of the Equipment....................................................................................................06
General Data .........................................................................................................................06
Technical Specifications ........................................................................................................13
Symbols.................................................................................................................................16
Dimensions............................................................................................................................18
Operation...............................................................................................................................20
Maintenance..........................................................................................................................22
Precautions ...........................................................................................................................22
Cleaning ................................................................................................................................24
Troubleshooting.....................................................................................................................26
Final Considerations ............................................................................................................27
Descripción del Producto........................................................................................................28
Garantía del Equipamiento ..................................................................................................... 31
Datos Generales ..................................................................................................................... 31
Especificaciones Técnicas...................................................................................................... 38
Simbolos ................................................................................................................................. 41
Dimensiones ........................................................................................................................... 43
Funcionamiento ...................................................................................................................... 45
Mantenimiento ........................................................................................................................ 47
Precauciones .......................................................................................................................... 47
Limpieza.................................................................................................................................. 49
Imprevistos.............................................................................................................................. 51
Consideraciones Finales ........................................................................................................ 52
English
3
DEAR CUSTOMER
Congratulations. You have made a good choice when you decided to buy a GNATUS QUALITY
product comparable to the best products available in the World. This manual is a general presentation of
your product and it will give you important details to help you to solve possible problems.
Please, read it and keep this with you.
The delivery unit is for odontological use, with starting and control of the syringe, high speed and low
speed motor and others, improving the best work field approach, designed for both left and right-handed
professionals, with X ray view, manometer, two aluminum trays and a removable and autoclavable
instruments support.
Manufacture with electronic control panel, which controls starting dental chair movements (seat up/
down movements, cuspidor position/last position and emergency stopping), Water Unit functions (cup
filling and bowl water flow), Bio-system operation, X ray view, and Scaler functions (Scaling, Endo and
Periodontal - available for use in the model GLXF FULL, model GLXC FULL, model GLXF, model GLXC,
model GLF SONIC e model GLC SONIC).
Unit also manufacture side control panel with manometer and main switch (available in all models),
Scaler intensity adjustment (available in the GLXF FULL, GLXC FULL, GLXF, GLXC, GLF SONIC e GLC
SONIC models) and electric low-speed-motor speed control and rotation direction adjustment (available
in the GLXF FULL e GLXC FULL models).
The case/ body is manufacture with Round-edged high-impact polystyrene.
The metal is in Steel built structure, with high shine smooth epoxy paint, polymerized in stove at
250ºC, with phosphated treatment resistant to rust and cleaning materials.
Automatic hand pieces selection, due to accurate pneumatic valves, making its use soft/easy.
Hand pieces support with easy access centered handle, both with round-edged finishing and made
of high-impact ABS (plastic) and Round, light and flexible hoses, without grooves. Gradual foot control for
hand pieces operation.
Disinfections system using the Bio-system, allowing hose and internal cleaning hand pieces using
disinfectant liquid, this preventing the risk of crossed contamination.
With Water reservoirs (for syringe and hand pieces spray), chlorinated water reservoir (for Bio-system)
and antiseptic liquids reservoir (for Scaler and bicarbonate jet procedures).
Easy access translucent reservoirs, with automatic pressurization.
The case/body is manufacture with Round-edged high-impact polystyrene connection box.
Composed have a removable and autoclavable round triple syringe, with revolving tip, high-speed-
motor low-speed-motor terminals and water valve (except TB units), as listed below.
• Delivery Unit Syncrus GL TB: 3 “Borden” terminals (2 holes);
• Delivery Unit Syncrus GL TB/FO: 2 “Borden” terminals (2 holes) and 1 “Midwest” terminal for FO;
• Delivery Unit Syncrus GL TM: 3 “Midwest” terminals (4 holes);
• Delivery Unit Syncrus GL TM/FO: 2 “Midwest” terminals (4 holes) and 1 “Midwest” terminal for FO;
• Delivery Unit Syncrus GL FULL (TM/FO/MME): 2 “Midwest” terminals for FO and 1 Bien-Air terminal
(8 holes) for MME
The Delivery Unit model GLXF FULL, GLXF, GLF SONIC, GLF JET, GLF OPTI and GLF are of the
flex type, fixed in the dental chair, with horizontal movements and an articulated arm which features
horizontal and vertical movements. They also feature a pneumatic arm locking device for vertical
movements, operated by a switch located on the unit body, performing a soft operation thanks to the
Teflon/bronze bore system.
The Delivery Unit Syncrus model GLXC FULL, GLXC, GLC SONIC, GLC JET, GLC OPTI and GLC
are of the Cart type, with a base mounted on four rollers. It’s made of steel, and has a round-edged
smooth-painted finishing.
ISO 9001/2000 and ISO 13485/2003 Quality System, assuryng the products are manufactured under
standart procedures.
PRODUCT DESCRIPTION
4
PRODUCT DESCRIPTION
Products manufactured in agreement with RDC 59 - ANVISA - (Sanitary Surveillance National Agency)
- with guarantees accomplishment hole to the sanitary legislation according to BPF - (Good Manufacturing
Procedures), requested by Mercosul Sanitary authorities.
In order to comply with directive 93/42/EEC for CE Mark purpose, it is defined that the working life of
metallic structure this product is estimated in 10 years (life-cycle) provided that the end-user follows the
requirements and instructions of this manual.
Note: Give preference to hand pieces and peripherals developed in accordance with requirements
of directive 93/42/EEC (with CE mark).
IMPORTANT:
This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certified professional, according to the legislation of the country) and following the
instructions of the manual. The operation of the equipment required, for the professional, the utilization
of correct instruments and it should to be in perfect conditions of the use, and to protect the professional,
the patients and others, in the eventual danger situation.
This equipment can’t be used in the presence of inflammable anesthetics or products that may
cause explosion.
· After finish life-cycle of the equipment, this equipment is throw way, so it should to be destroyed in
appropriate area (according to the legislation of the country).
•To guarantee the safe functioning of your equipment, use only the assemble configurations (Dental
Chair, Dental and Water Units and Dental Light) supplied by Gnatus authorized Dealers / Technical
Assistance.
Delivery units are composed according to list below:
Delivery Units Syncrus model GLXF FULL and Syncrus model GLXC FULL
- 1 triple syringe.
- 1 low-speed-motor terminal (MME).
- 2 high-speed-motor terminals (FO)
- 1 bicarbonate jet (autoclavable).
- 1 Scaler piezo-electric device with a 29.000Hz frequency.
Delivery Units Syncrus model GLXF and Syncrus model GLXC
- 1 triple syringe.
- 1 low-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM/FO).
- 1 bicarbonate jet (autoclavable).
- 1 Scaler piezo-electric device with a 29.000Hz frequency.
Delivery Units Syncrus model GLF SONIC and Syncrus model GLC SONIC
- 1 triple syringe.
- 1 low-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM/FO).
- 1 Scaler piezo-electric device with a 29.000Hz frequency.
Delivery Units Syncrus model GLF JET and Syncrus model GLC JET
- 1 triple syringe.
- 1 low-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM/FO).
- 1 autoclavable bicarbonate jet.
English
5
PRODUCT DESCRIPTION
Delivery Units Syncrus model GLF OPTI and Syncrus model GLC OPTI
- 1 triple syringe.
- 1 low-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM/FO).
- 1 Optilight LD
Delivery Units Syncrus model GLF and Syncrus model GLC
- 1 triple syringe.
- 1 low-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM).
- 1 high-speed-motor terminal (TB/TM/FO).
Product Description - Scaler
See Scaler´s Owner´s Manual
Product Description - Optilight LD
The Optilight LD is the newest generation of equipment activated by light LED. This abbreviation is
the acronym for Light Emitting Diode, a totally different way to emit light, when compared to the
conventional equipments with halogen light. Instead of the traditional equipments which generate light in
wide wave spectrum and much heat, this technology allows the emission of cold light, at a precise length
of wave to activate the several dental applicable products.
The LED technology, recently introduced in Dentistry, brought several advantages to the
photopolymerizer equipments for direct restoration of compounded resin. Besides that it is infinitely more
durable the LED turned the equipments more compact, ergonomic and easy for installation and transport.
The emission of cold light and the precise length of waves grant the secure polymerization of composite
activated by camphoroquinone without risks of dental heating, pulp injury or discomfort for both
professional and patient. Although a new technology, it has already its second generation. The safety and
efficiency of LEDs, now with high energy of emission, its useful to all clinical procedures which need the
potency of light for photo activation, including the ambulatorial bleaching treatment.
The wave length of 470nm associated to high energy generated by Optilight LD makes possible
the multifunction of this equipment:
· Direct restoring procedures: compounded resins, ionomers and adhesives.
· Indirect restoring: adhesive cementation of laminates, inlays, esthetic pins and metal-free crowns.
· Dental bleaching: activation of bleaching gel and polymerization of gingival barriers. Compatible to
bleaching gels made of 35% hydrogen peroxide.
· Adhesion of brackets and orthodontic accessories.
· Activation of photoactivated materials as sealants, surgical cements and basis of reinforcement.
Engineered and built under the most advanced technology to provide results within the specification
standards required by the world’s highest dental authorities.
Operating control on the hand-piece, sound alarm with a beep every 10 seconds and long beep
every 90 seconds.
Optilight LD Advantages:
• More selective spectral light than conventional lamps.*
• Cold light doesn’t heat up the resin nor the tooth.**
• Light compact equipment that provides handling comfort.
• Low power consumption.
• Longer useful life of the light emitting diode (equivalent to 36.000.000 cycles of 10 seconds).
• It does not use optical filter.
• It does not require forced ventilation avoiding noise emission.
(* We observed that the light emitted by the Optilight LD is completed contained within the interval of
the photo starter, therefore it’s 100% used, whereas the conventional equipment running on halogen
6
GENERAL DATA
WARRANTY OF THE EQUIPMENT
This warranty covers product’s manufacturing faults for the warranty period and standards specified
on the Warranty Certificate. The Warranty Certificate is attached to product, and must be completed by
the authorized technician when equipment is installed.
Doubts and information: GNATUS Call center (55-16) 2102-5000.
Maintenance of the equipment
The equipment doesn’t need preventive maintenance, however when there is any problem that this
manual can’t solve, ask for an Authorized Gnatus Technician.
List of pieces and circuit scheme
Gnatus Company declares that the supply of the circuit scheme, list of pieces or any other information
that propitiate technical attendance for the user, can be request if there is an agreement between the
user and Gnatus Company.
PRODUCT DESCRIPTION
lamps lose a great deal in the process.
** The Optilight LD doesn’t generate heat since uses light emitting diode.
The light conductor is removable, made out of high resistance polymer and easy maintenance.
The reduced hand-piece weight with its anatomic design assures a more comfortable and practical
handling to the professional.
English
7
GENERAL DATA
Syncrus GLXF FULL 01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminals (FO)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
10 - Bicarbonate jet
11 - Delivery unit main switch
12 - Scaler potentiometer
13 - Electric low-speed-motor
potentiometer
14 - Electric low-speed-motor
rotation inverter
15 - Manometer
16 - Bicarbonate reservoir
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment valve /
FO / MME / Scaler / Bicarbonate jet
01
02
03
04
05
07
08
09
10
11 12 13
14
15
16
17
18
20
21
22
23
19
Syncrus GLXC FULL
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminals (FO)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
10 - Bicarbonate jet
11 - Delivery unit main switch
12 - Scaler potentiometer
13 - Electric low-speed-motor
potentiometer
14 - Electric low-speed-motor
rotation inverter
15 - Manometer
16 - Bicarbonate reservoir
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment valve /
FO / MME / Scaler / Bicarbonate jet
24 - Rotation of the pedestal
25 - Pedestal
01
02
03
11 12
15
16
25
24
20
21
23
19
04
05
07
08
09
10
1314
8
GENERAL DATA
Syncrus GLXF 01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminals (TB/
TM/FO)
06 - High-speed-motor terminals (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
10 - Bicarbonate jet
11 - Delivery unit main switch
12 - Scaler potentiometer
15 - Manometer
16 - Bicarbonate reservoir
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment valve
/ FO / Scaler / Bicarbonate jet
01
02
03
04
05
07
08
09
10
11 12
15
16
17
18
20
21
22
23
19
Syncrus GLXC
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminals (TB/
TM/FO)
06 - High-speed-motor terminals (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
10 - Bicarbonate jet
11 - Delivery unit main switch
12 - Scaler potentiometer
15 - Manometer
16 - Bicarbonate reservoir
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment valve
/ FO / Scaler / Bicarbonate jet
24 - Rotation of the pedestal
25 - Pedestal
01
02
03
11 12
15
16
25
24
20
21
23
19
04
05
07
08
09
10
06
06
English
9
GENERAL DATA
Syncrus GLF SONIC
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
11 - Delivery unit main switch
12 - Scaler potentiometer
15 - Manometer
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment valve
/ FO / Scaler
Syncrus GLC SONIC
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
09 - Scaler
11 - Delivery unit main switch
12 - Scaler potentiometer
15 - Manometer
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment valve
/ FO / Scaler
24 - Rotation of the pedestal
25 - Pedestal
01
02
03
11 12
15
25
24
20
21
23
19
04
05
07
08
09
06
01
02
03
04
05
07
08
11 12
15
17
18
20
21
23
19
06
09
22
10
GENERAL DATA
Syncrus GLF JET
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
10 - Bicarbonate jet
11 - Delivery unit main switch
15 - Manometer
16 - Bicarbonate reservoir
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment valve
/ FO / Bicarbonate jet
Syncrus GLC JET
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
10 - Bicarbonate jet
11 - Delivery unit main switch
15 - Manometer
16 - Bicarbonate reservoir
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment valve
/ FO / Bicarbonate jet
24 - Rotation of the pedestal
25 - Pedestal
01
02
03
11
15
16
25
24
20
21
23
19
04
05
07
08
10
06
10
01
02
03
04
05
07
08
11
15
16
17
18
20
21
22
23
19
06
English
11
GENERAL DATA
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal
(TB/ TM/FO)
06 - High-speed-motor terminal
(TB/ TM)
07 - Centered handle
08 - Low-speed-motor terminal
(TB/TM)
11 - Delivery unit main switch
15 - Manometer
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment
valve / FO
26- Optilight LD
40 - Timer trigger button
41 - Ocular protector
42 - Light conductor
57 - Light conductor Whitening Tip
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal
(TB/TM/FO)
06 - High-speed-motor terminal
(TB/TM)
07 - Centered handle
08 - Low-speed-motor terminal
(TB/TM)
11 - Delivery unit main switch
15 - Manometer
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment
valve/ FO
24 - Rotation of the pedestal
25 - Pedestal
26 - Optilight LD
40 - Timer trigger button
41 - Ocular protector
42 - Light conductor
57 - Light conductor Whitening Tip
Syncrus GLF OPTI
Syncrus GLC OPTI
01
02
03
04
05
07
08
26
06
19 17
18
20
21
15
11
22
23
42
40
57
41
01
02
03
11
15
25
24
20
21
19
04
05
07
08
26
06 23
40
57
41 42
12
GENERAL DATA
Syncrus GLF
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
11 - Delivery unit main switch
15 - Manometer
17 - Articulated arm
18 - Arm column
19 - Instrument’s support
20 - Connection box
21 - Foot control
22 - Arm’s brake valve
23 - Syringe water adjustment valve
/ FO
01
02
03
04
05
07
08
11
15
17
18
20
21
22
23
19
Syncrus GLC
01 - Auxiliary trays
02 - Control panel
03 - X ray view
04 - Triple syringe
05 - High-speed-motor terminal (TB/
TM/FO)
06 - High-speed-motor terminal (TB/
TM)
07 - Centered handle
08 - Low-speed-motor terminal (TB/
TM)
11 - Delivery unit main switch
15 - Manometer
19 - Instrument’s support
20 - Connection box
21 - Foot control
23 - Syringe water adjustment valve
/ FO
24 - Rotation of the pedestal
25 - Pedestal
01
02
03
11
15
25
24
20
21
23
19
04
05
07
08
06
06
English
13
TECHNICAL SPECIFICATIONS
Product classification:
In compliance with
NBR IEC 60601-1
Inlet air pressure
80 PSI (5,52 BAR)
Inlet air pressure - Syringe
40 PSI (2,76 BAR)
Air
Use dry and filtered air
Power inlet
12V~ and 24V~ (from dental
chair)
Degree of protection
against electric shock:
B type
Electric shock protection
type:
Class one equipment.
Operation mode
Continuous with intermittent
load
Water leak protection
Electromagnetic compatibility
This product was tested and approved in compliance with the following standards:
EN 60601-1 (1990);
Amendment 1 EN 60601-1 (1992);
Amendment 2 EN 60601-1 (1995);
Amendment13 EN 60601-1 (1995);
EN 60601-1-2 (2001);
NBR IEC 601-1 (1994);
Emenda 1 NBR IEC 601-1
(1994);
NBR IEC 601-1-2 (1997);
CISPR 11, edição 3.1 (1999);
IEC 61000-4-2 (1999);
IEC 61000-4-3 (1998);
IEC 61000-4-4 (1995);
IEC 61000-4-5 (1995);
IEC 61000-4-6 (1996);
IEC 61000-4-11 (1996);
Scaler:
Operation mode:
Continuous with intermittent load, T-ON 1 min. T-OFF 4 min.
Others informations: Check Scaler owner’s manual
Standards
This equipment was designed, manufactured and tested in compliance with the following standards:
NBR-IEC série 601-1 Equipamento Eletromédico - Parte 1: Prescrições gerais para segurança;
EN 980:2003 (Ed. 2) - Graphical symbols for use in the labelling of medical devices;
ISO 14971 - Medical devices - application of risk management medical devices;
ISO 9687: 1993 - Dental equipment - graphical symbols;
ISO 7494 - Norma dental units;
ISO 13485-2 - Quality systems - medical devices;
ISO 780 - Packaging - pictorial marking for handling goods;
ISO 11144 - Norma dental equipment - connections for suply and waste lines;
IPX 0
Application together with
anesthetic products that
could be inflammable in
the presence of air, oxygen
or nitrous oxide:
Not recommended
Delivery unit tray’s
maximum load capacity
2Kgf
Net weight Gross weight
Syncrus GLXF FULL Delivery Unit 23 kg Syncrus GLXF FULL Delivery Unit 28 kg
Syncrus GLXC FULL Delivery Unit 16,10 kg Syncrus GLXC FULL Delivery Unit 19,80 kg
Syncrus GLXF Delivery Unit 22,80 kg Syncrus GLXF Delivery Unit 27,80 kg
Syncrus GLXC Delivery Unit 15,90 kg Syncrus GLXC Delivery Unit 19,60 kg
Syncrus GLF SONIC Delivery Unit 22 kg Syncrus GLF SONIC Delivery Unit 27 kg
Syncrus GLC SONIC Delivery Unit 15,10 kg Syncrus GLC SONIC Delivery Unit 18,80 kg
Syncrus GLF JET Delivery Unit 22,30 kg Syncrus GLF JET Delivery Unit 27,30 kg
Syncrus GLC JET Delivery Unit 15,40 kg Syncrus GLC JET Delivery Unit 19,10kg
Syncrus GLF OPTI Delivery Unit 21,60 kg Syncrus GLF OPTI Delivery Unit 26,60 kg
Syncrus GLC OPTI Delivery Unit 14,70 kg Syncrus GLC OPTI Delivery Unit 18,40 kg
Syncrus GLF Delivery Unit 21,30 kg Syncrus GLF Delivery Unit 26,30 kg
Syncrus GLC Delivery Unit 14,40 kg Syncrus GLC Delivery Unit 18,10 kg
14
Special providence or particular conditions for installation
- Check the electric net, it must be compatible with the specified one in the equipment.
- Verify the thread earth, it must be turned off correctly.
- Verify the general key of the equipment in the position “0”.
OBS: These information also make part of the Manual of Installation and Maintenance of the equipment
that can be found with the authorized Gnatus technician.
Transport and storage conditions
The equipment must be transported and stored with the following observations:
- Carefully, should not suffer drop and neither receive impact.
- With the side of the arrow upward.
- With humidity protection, not to expose to rains, sparkling of water or humidified floor.
- With temperatures from -12ºC to 50ºC
Flex delivery units
- With maximum piling up of 07 units for storage.
Cart delivery units
- With maximum piling up of 04 units for storage.
Content of accessible and non-accessible demarcations
Operation mode:
Continuous with intermittent
load, 90 sec. operating with a
pause of 90 seg.
Electric shock protection
type:
Class one equipment.
Degree of protection against
electric shock:
BF type
• Input
5,2V
Optilight LD:
• Power
5,2VA.
Light source
1 LED.
Active device
Semicondutor LED (InGaN).
Wave length
470 nm
• Timer
90 seconds.
Time beep
A short beep every 10 sec.
and a long beep after 90 sec.
• Operation
Pen’s button
Light condutor
Made of special polymer,
revolving, removable and
recyclable.
Pen body
Made of anodized aluminum.
Warning:
The acrylic light conductor (pointer) is a material widely used in the dentist industry in partial and
complete prosthesis, orthodontic device, implants and many other applications that guarantees its
bio-compatibility with the mouth mucus.
TECHNICAL SPECIFICATIONS
English
15
TECHNICAL SPECIFICATIONS
Hand pieces position
A - Triple syringe
B - High-speed with FO
C - Electric low-speed-motor
D - Scaler
Syncrus GLX F/C FULL Delivery Unit Syncrus GLX F/C Delivery Unit
Syncrus GL F/C SONIC Delivery Unit Syncrus GL F/C JET Delivery Unit
Syncrus GL F/C OPTI Delivery Unit Syncrus GL F/C Delivery Unit
E - Bicarbonate Jet
F -High-speed terminal
G - Low-speed-motor terminal
H - Optilight LD
16
TECHNICAL SPECIFICATIONS
Product symbols
High-speed with FO (available in
GLXF FULL, GLXC FULL and FO
Delivery Units)
Lift seat. Lower seat.
Lift backrest. Lower backrest.
Emergency stop It determines to spitting position / last
position.
Bio-System operation X ray view operation
Bowl’s water flow Cup filling
High-speed terminal Low-speed-motor terminal
Optilight LD (available in GLF OPTI
and GLC OPTI Delivery Units)
Triple syringe Bicarbonate Jet (available in GLXF
FULL, GLXC FULL, GLXF, GLXC,
GLF JET and GLC JET Delivery Units)
Turned on Turned off
Scaler indicator key (available in the
GLXF FULL, GLXC FULL, GLXF,
GLXC, GLF SONIC and GLC SONIC
Delivery Units).
Perio function operation (available in
the GLXF FULL, GLXC FULL, GLXF,
GLXC, GLF SONIC and GLC SONIC
Delivery Units).
English
17
TECHNICAL SPECIFICATIONS
Product symbols
Packing symbols
Endo function operation (available in
the GLXF FULL, GLXC FULL, GLXF,
GLXC, GLF SONIC and GLC SONIC
Delivery Units).
Scaling function operation (available in
the GLXF FULL, GLXC FULL, GLXF,
GLXC, GLF SONIC and GLC SONIC
Delivery Units).
Warning - Consult the manual
Electric low-speed-motor rotation
inverter (available in the GLXF FULL
and GLXC FULL Delivery Units).
Electric low-speed-motor (available
in the GLXF FULL and GLXC FULL
Delivery Units).
Landing (in many parts of the
equipment) indicates the condition of
being landed.
B type equipment
Packing (flex delivery units) to be
stored with a maximum stack of 7 units.
Packing (cart delivery units) to be
stored with a maximum stack of 4 units.
04 07
Packing to be transported and / or
stored avoiding humidity, rains and wet
floor.
Packing to be transported and / or
stored with the harrows up.
Packing to be transported and / or
stored with care (should not suffer drop
and neither receive impact).
Temperature limit for the packing to be
stored or transported.
The packing must be stored and
transported away from direct sun light
exposure.
18
TECHNICAL SPECIFICATIONS
Dimensions (mm) (Syncrus GLXF FULL, GLXF, GLF SONIC, GLF JET, GLF OPTI and GLF Delivery Units)
Note: Drawing above represents a GLXF Delivery Unit. All other models have identical dimensions.
English
19
Dimensions (mm) (Syncrus GLXC FULL, GLXC, GLC SONIC, GLC JET, GLC OPTI and GLC delivery units)
TECHNICAL SPECIFICATIONS
Note: Drawing above represents a GLXC Delivery Unit. All other models have identical dimensions.
20
OPERATION
Command panel
27 -Scaling function operation (available in the
GLXF FULL, GLXC FULL, GLXF, GLXC, GLF
SONIC and GLC SONIC Units).
28 - Endo function operation (available in the GLXF
FULL, GLXC FULL, GLXF, GLXC, GLF SONIC
and GLC SONIC Units).
29 - Perio function operation (available in the GLXF
FULL, GLXC FULL, GLXF, GLXC, GLF SONIC
and GLC SONIC units).
30 -Bio-System operation
31 -X ray view operation
32 -Last position / Spitting position
33 -Cup filling
34 -Bowl’s water flow
35 -Rise seat.
36 -Lower seat.
37 -Emergency stop.
38 -Rise backrest.
39 -Lower backrest.
Warning:
To preset the cup filling time, press the “Cup filling” key (33) for 3 seconds (a long beep will be heard
and the LED will keep blinking).
When the desired time is reached, press the “Cup filling” key again. The cup filling time is then set.
To preset the bowl’s water flow, pres the “Bowl water” key (34) for 3 seconds (a long beep will be
heard and the LED will keep blinking)
When the desired time is reached, press the “Bowl water” key again. The cup filling time is then set
The “Cup filling” and “Bowl water” time functions have a limited preset flow time, 1 minute for the cup
filling and 4 minutes for the bowl’s water flow.
When the key “Last position/Spitting position” (32) is pressed, the dental light will go off (if it was on), the
bowl will drain (for the preset time, and if it was not programmed yet, for four minutes) and the backrest will
go up to the spitting position. When pressed again, the backrest will return to the last position and the dental
light will go on (if it was on).
After pressing the “Last position/spitting position” key (32), any other operation will trigger the “Stop”,
and automatically the backrest current position will be defined as “Last position”.
When the “Emergency stop” (21) key is pressed, all chair movements are interrupted and blocked until
pressed again.
27 28 29
3031
32 34
33 35
38
37
3936
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27