PowerTrak™ Vent Machine
Override Three Wire
Figure 1
This harness is used to override the controller while in tunnel to close the vent machines. This harness
only works with three wire PowerTrak™.
Directions
1. Disconnect the power from the PowerTrak™.
2. Disconnect the control wires from the PowerTrak™, (HOT OUT, OPEN IN, CLOSE IN).
3. Connect the control wires to harness (1903-0108). HOT OUT, CLOSE and OPEN wires from the
control connects to YELLOW wire, RED wire and BROWN wires with the connector respectively.
4. Connect the harness to the PowerTrak™. YELLOW, BROWN and RED wires will have stripped ends
and connects to HOT OUT, OPEN IN and CLOSE IN respectively.
5. Connect the WHITE wire from harness to NEUT of PowerTrak™.
6. Connect the ORANGE wire from harness to the desired tunnel stage in contactor control panel. This
wire will connect to the HOT side of the coil.
7. Make sure the power supply for both, PowerTrak™ and contactor control panel are wired correctly,
i.e. WHITE is NEUTRAL, BLACK is HOT, and GREEN is GROUND before turning ON the power
supply.
White
Power
Supply
USE WIRES SPECIFIED
LOWER AUX: PINK & TAN CONTROLLER AC IN
HOT
NEUT
GND.
HOT
OUT
OPEN
IN
CLOSE
IN
UPPER AUX: L. BLUE & BROWN
AUX
SWITCH
PowerTrak™
Brown
Red
Yellow
Brown
Red
Open
Close From Control
Source
Hot Out
Yellow
(Orange) Signal
To CCS Panel
Hot side of coil
on contactor of
the desired
TUNNEL STAGE