APC Link 2 Two Channel WiFi Switch User guide

Type
User guide

APC Link 2 Two Channel WiFi Switch lets you control two separate devices or appliances using your smartphone from anywhere in the world. With its easy-to-use app, you can set schedules, countdowns, and even share control with others. The Link 2 is perfect for automating your home, whether you want to control your lights, fans, or even your garage door opener.

APC Link 2 Two Channel WiFi Switch lets you control two separate devices or appliances using your smartphone from anywhere in the world. With its easy-to-use app, you can set schedules, countdowns, and even share control with others. The Link 2 is perfect for automating your home, whether you want to control your lights, fans, or even your garage door opener.

Link 2
Working VoltageAC/DC 7-32V
Wi-Fi: 2.4GHZ
Working Temperature-2070
Maximum Current Switching: 10A
®
Two Channel Wi-Fi Switch
Overview
Specifications
AC/DC
7-32V
No Polarity
Relay 2
Output
Status
LED
Relay 2 Test
Reset Relay 1 Test
Relay 1
Output
5V USB Power
Reset
1. Hold Down the LEFT “Reset” button for five
second and release.
2. LED Indicator will then begin to flash
red. The red flash indicates the unit has
been reset and ready to be connected to
the home owners device.
3. Within the app press + and you
should be prompted automatically
to add the new device.
4. Input your Wi-Fi
password after ensuring
you are connected to you
2.4GHZ Wi-Fi network.
4. The process of configuration will take
up to one minute to complete.
Your home Wi-Fi
Your Wi-Fi password
APP Preparation (Home Owners Device)
1. Go to “Me” 2. Go to
“Home Management”
3. Select “My Home...”
4. Name the home
5. Set the Location
6. Deselect ALL
the rooms
except the one
where the indoor
monitor is
installed.
7. Press Save
APP Configuration
Device Configuration
APP Install and Registration (All Users)
1. Download Tuya Smart from the APP Store on your Android/Apple Device.
2. Open the App and register an account ensuring you select “Australia” as the country
3. Login after registration. NOTE: Each user must register there own account.
Reset
Sharing with another user
Operation
Setting to inching (relay time)
1. Go to “Me” 2. Go to
“Home
Management”
2. Choose the
relay you
wish to
configure
3. Choose Inching
4.Set to ON
5.Set the time:
- Gate/Garage Automation 2 Seconds
- Electric Strikers/Magnetic Locks connected
THROUGH link 2, Set to 5 seconds
- Electric Strikers/Magnetic Locks connected via
PS-L3S or other lock control power supplies,
Set to 2seconds
1. From the
main screen
go to “timer”
3. Select the
home you
wish to share
4. Select the rooms you wish to
share
5. Select Add Member
6. Select
Tuya APP
Account
7. Input the User Name
9. Set the Users role
Administrator
Total Control over home including
unlocking and adding/deleting
users
My Home My Home
Home User
Press SAVE an invitation will be sent to
the user
Common Member
Control of devices operation
OR
Time Related Settings
- Countdown
- Scheduled
Circulating
- Random
- Relay Setting
Trigger Relay 1
Latching circuit by default
See “Inching” setting
for electric locks and gate/
garage automation
Trigger Relay 2
See momentary setting
for electric locks and gate/
garage automation
Trigger Both Relays ON Trigger Both Relays OFF
110
2TS
3P 2
7CX
ONE CL
PE
1
OP
GND
COM
+
18V
PE
2
Red (+18V)
Black (GND)
Blue (ONE)
Purple (COM)
Red (10)
Green (3P)
Black (2)
Blue (7)
Purple (2)
Purple (2)
Power For BEAM
P
.B.1
LOOP
P
.B.2
GND
GND
GND
+V
+V
--
BEAM
GND
RED (+V)
BLACK (-) PURPLE (GND)
PURPLE (GND) Pedestrian Feature DOUBLE GATE ONLY PURPLE to GND
Double Gate connect to PB2
Single Gate connect to PB1
• APC-SG802-AC Typhoon •APC-SG1600-AC Tsunami •APC-SG3000-AC Tornado
• APC-P400 Proteous 400
• APC-P450S Proteous 450 Sprint • APC-P500 Proteous 500
• APC-Logico 24 Swing Gate System
• APC-CBSW12 • APC-CBSW24 Swing Gate System
Set to “Inching” 2 Seconds
Set to “Inching” 2 Seconds
for BOTH relays
Set to “Inching” 2 Seconds
for BOTH relays
Set to “Inching” 2 Seconds
for BOTH relays
Set to “Inching” 2 Seconds
for BOTH relays
Black (E2 COM)
Red(E1 +V DC)
Purple (J9 COM)
Purple (J9 COM)
Blue (J1 START)
Green (J2 P. START)
Purple (L6 COM)
Blue (L3 START)
Green
(L4 P. START)
Black (K7 COM)
Red (K6 +V DC)
OPTIONAL
OPTIONAL
OPTIONAL
* Optional connection determines
the ability to toggle pedestrian
function from the Wi-Fi Switch
* Optional connection determines
the ability to toggle pedestrian
function from the Wi-Fi Switch
* Optional connection determines
the ability to toggle pedestrian
function from the Wi-Fi Switch
Pedestrian Feature DOUBLE GATE ONLY GREEN to PB1
Set to “Inching” 2 Seconds
Connection to PS-L3S Lock Control System
Control -
12V
PUSH
+NC
Control +
- COM
GND
+NO
GND Black & Purple
12V Red
PUSH Blue
-COM Electric Striker/Magnetic Lock Negative
+NC Electric Striker (FAIL SAFE)/Magnetic Lock Positive
+NO Electric Striker (FAIL SECURE)
Set to “Inching” 2 Seconds
*Time is set on the PS-L3S
RED (+)
BLACK (-)
BLUE
Common for O/S/C or Open/Close Input
O/S/C or Open/Close Input
All Other Automatic Gate/Garage Systems
Positive
Red
Negative
Black
Power Supply or System Power 7/32V AC/DC ONLY
PURPLE
NO+
-COM
-COM
NC+
Red
Orange
Black
Blue
Electric Striker to PS-L3S Magnetic Lock to PS-L3S
APC WARRANTY
APC Automation Systems warrants the original purchasers or the APC gate(s) opening system for a period of twelve months from the date of
purchase (not installation), the product shall be free of defects in materials and workmanship under normal use.
During the warranty period, APC shall, as its option, repair or replace any defective product upon return of the product to its factory, at no
charge for labour and materials.
Any replacement and/or repaired parts are warranted for the remainder of the original warranty, The original owner must promptly notify APC
in writing that there is defect in material or workmanship, such written notice must be received in all events prior to expiration of the warranty.
International Warranty
APC shall not be responsible for any freight fees, taxes or customs fees.
Warranty Procedure
To obtain service under this warranty, AND AFTER CONTACTING APC, please return the item(s) in question to the point of purchase.
All authorized distributors and dealers have a warranty program, anyone returning goods to APC must first obtain an authorization number.
APC will not accept any shipment for which prior authorization has not been used.
Conditions to Void Warranty
This warranty applies only to defects in repairs and workmanship relating to normal use. It does not cover:
- Damage incurred in shipping or handling
- Damage caused by disaster such as fire, flood, wind, earthquake or lightning
- D amage due to causes beyond the control of APC such as excessive voltage, mechanical shock or water damage
- Damage caused by unauthorized attachment, alterations, modifications, or foreign objects.
- Damage caused by peripherals (unless such peripherals were supplied by APC)
- Defects caused by failure to provide a suitable installation environment for the products
- Damage caused by usage of the products for purpose other than those for which it was designed.
- Damage from improper maintenance
- Damage arising out of any other abuse, mishandling, and improper application of the products.
Under no circumstances shall APC be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of
contract, negligence, strict liability, or any other legal theory. Such damages include, loss of profits, loss of the product or any associated
equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser's time, the claims of third
parties, including customers, and injury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether expressed or implied (including all
implied warranties of merchantability or fitness for a particular purpose). And of all other obligations or purporting to act on its behalf to modify
or to change this warranty, nor to assume for it any other
warranty or liability concerning this product.
Out of Warranty Repairs
APC will at its option repair or replace out-of-warranty products which are returned to its factory according to the following conditions.
Anyone returning goods to APC must first obtain an authorization number.
APC will not accept any shipment whatsoever for which prior authorization has not been obtained.
Products which APC determines to be repairable will be repaired and returned. A set fee which APC has been predetermined and which may be
revised from time to time will be charged for each unit repaired. Products which APC determines not repairable will be replaced by the nearest
equivalent product available at that time. The current market price for the replacement product will be charged for each replacement unit.
Warranty Terms
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

APC Link 2 Two Channel WiFi Switch User guide

Type
User guide

APC Link 2 Two Channel WiFi Switch lets you control two separate devices or appliances using your smartphone from anywhere in the world. With its easy-to-use app, you can set schedules, countdowns, and even share control with others. The Link 2 is perfect for automating your home, whether you want to control your lights, fans, or even your garage door opener.