4000

Johnson Controls 4000 User manual

  • Hello! I am an AI chatbot trained to assist you with the Johnson Controls 4000 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Johnson Controls
Unitary Products
TECHNICAL GUIDE
4000, 5000, 6000, 7000 & 8000 SERIES HUMIDIFIERS
• Humidifiersforvirtuallyeveryapplication.
• Purchasedbyhomeownersforhealth,comfort,preservationandenergysavings.
• Fastandeasytoinstallandmaintain.
• Provendesignensuresoptimumperformanceandlongproductlife.
Humidifier Dimensions
5000 Small Bypass
6000 Large Bypass and
4000 Water Saver 7000 Large Fan Power 8000 Canister Steam
HumidifierWidth
15-5/8”including
solenoidvalve
15-3/8”including
solenoidvalve
15-29/32” 10-1/8”
HumidifierHeight 13”includingdrainspud
15-3/4”includingdrain
spud
18”includingsolenoid
valveanddrainspud
20-7/8”includingdraincup
HumidifierDepth 10-1/4” 10-1/4” 10-11/32” 7-1/8”
BypassDuctOpening 6”diameter 6”diameter N/A N/A*
PlenumOpening 9-1/2”Wx9-1/2”H 10”Wx12-3/4”H 14-3/4”Wx14-5/16”H N/A*
*Humidifier can be remote mounted. Dispersion tube requires 1-1/4” diameter hole in supply or return duct.
Humidifier Specifications
Humidifier
Type
Sizing
Sq. Ft. Area
(air changes/hr)
A. Unit Size
(inches)
B. Plenum
Opening
(inches)
Bypass
Connection
Size
Water Feed
Rate
Electrical
Data
UL
Approved
Components
Included
8000 Series
Canister
Steam
Humidifier
120V operation:
750loose(2),1,500average
(1),3,000tight(1/2)
208V operation:
1,350loose(2),2,650average
(1),5,350tight(1/2)
240V operation:
1,500loose(2),3,050average
(1),6,100tight(1/2)
A. 10-1/8Wx
20-7/8Hx
7-1/8D
B. N/A–Unit
canberemote
mounted.
N/A–
Dispersion
tubemounts
through
1-1/4”hole
insupplyor
returnduct.
N/A–Total
waterusage
isoutputplus
approximately
20%fordrain
cycles.
120V-60Hz:
11.5AMP,
1.4kW
208V-60Hz:
11.5AMP,
2.4kW
240V-60Hz:
11.5AMP,
2.8kW
UL
Approval
certified
byETL
ManualHumidistat,
DispersionTube,
SteamHose,Drain
Hose,HoseClamps,
BlowerActivation
Relay,Installation/
Operation&
MaintenanceManual,
OwnersManual
7000 Series
Power
Humidifier
1,050loosehouse(2)
2,100averagehouse(1)
4,200tighthouse(1/2)
A. 15-29/32Wx
18Hx
10-11/32D
B. 14-3/4Wx
14-5/16H
N/A 6gph
120V-60Hz
0.8AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual
6000 Series
Bypass
Humidifiers
1,000loosehouse(2)
2,000averagehouse(1)
4,000tighthouse(1/2)
A. 15-3/8Wx
15-3/4Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 10Wx
12-3/4H
6” 3gph
24V-60Hz
0.5AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
4000 Series
Water Saver
Bypass
Humidifiers
1,000loosehouse(2)
2,000averagehouse(1)
4,000tighthouse(1/2)
A. 15-3/8Wx
15-3/4Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 10Wx
12-3/4H
6” 3gph
24V-60Hz
0.5AMP
No
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
5000 Series
Bypass
Humidifiers
750loosehouse(2)
1,500averagehouse(1)
3,000tighthouse(1/2)
A. 15-5/8Wx
13Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 9-1/2Wx
9-1/2H
6” 3gph
24V-60Hz
0.5AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
Series 8000, 7000, 6000, 5000, 4000 humidifier performance based on:
a. 20°F and 70% R.H. Outside Air
b. 0°F and 35% R.H. Room Air
c. Internal Moisture Gain of 1 lb/hr
d. 70% Blower Operation
e. 8 Ft. Ceiling Height
Johnson Controls
Unitary Products
5005YorkDrive,Norman,OK73069
665513-UTG-B-1211
JohnsonControls,UnitaryProductsreservesthe
righttochangespecificationswithoutnotice.
/