  • Hello! I am an AI chatbot trained to assist you with the Dell PowerConnect W-IAP224/225 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AP-220-MNT-C2
Installation Guide
0511289-03 | August 2013 1
The AP-220-MNT-C2 ceiling rail adapter kit includes the following items:
Adapter for Open (Silhouette) ceiling tile rails. The wider of the two adapters.
Adapter for Flanged (Interlude) ceiling tile rails. The narrower of the two adapters.
For complete information about selecting the location and setting up the AP, see the Access Point
Installation Guide.
Installation
To attach either ceiling rail adapter to the AP:
1. Place the adapter against the back of the AP with the adapter at an angle of approximately 30 degrees to
the tabs (see Figure 1).
2. Twist the adapter clockwise until it snaps into place in the tabs (see Figure 1).
Figure 1 Adapter Installation
This mount kit supports multiple AP models. All installation images show the 225 AP.
AP-220_15
2 AP-220-MNT-C2 | Installation Guide
After the adapter is attached to the AP, mount the AP on a ceiling tile rail as follows:
1. Align the AP with a ceiling tile rail, placing the AP so that the mounting tabs on the adapter are at an
angle of approximately 30 degrees to the ceiling tile rail (see Figure 2 or Figure 3).
Make sure that slack in connected cables is above the ceiling tiles.
2. Pushing toward the ceiling tile, rotate the AP clockwise until it clicks into place on the ceiling tile rail
(see Figure 2 or Figure 3).
Figure 2 Open Rail Installation
Figure 3 Flanged Rail Installation