Alarmtech PSV 1225-18 User manual

Type
User manual
© 2017 Alarmtech www.alarmtech.pl 1 / 4 PSV 1225-18 1716en
12 VDC/2.5 A
Power Supplies Battery 18 Ah/Security grade 2
Instruction manual PSV 1225-18
DESCRIPTION
PSV 1225-18 is an up-to date power supply unit with bat-
tery backup compliant with EN regulations for social and
security alarm systems. Unit provides all features required
by EN 50131-6:2008, security grade 2 and many other
available in grade 3 only.
Distinctive and unique feature of PSV 1225-18 is invented
by Alarmtech ViP mode Voltage-in-Parallel. Power sup-
ply units with ViP feature can be connected in parallel both
(+) and (-) on one common power bus without a need of
additional synchronization. Connected units will share
load on a bus. ViP feature can be used to build distributed
and redundant power systems. It can be also used to com-
pensate voltage drops on a bus by placing power supply
units in distant bus sections.
Power conversion is based on high frequency SMPS regu-
lator providing high conversion efficiency. Low losses in-
side unit preserve batteries from overheating shortening
battery life time. Computerized battery recharging circuit
works in constant current limited voltage mode the
most advanced and the best mode to provide the longest
possible battery life time.
Power unit is equipped with built-in diagnostic system de-
tecting and signalling mains failure, different battery fail-
ures including end-of-life warning, output faults like low
voltage or broken fuse.
MAIN FEATURES
EN 50131-6:2008 compliant, security grade 2
Type A, with backup battery
Nominal output voltage: 13.8 V DC
Total current capacity: 2.5 A
ViP (Voltage-in-Parallel) feature increasing reliability
and capacity of power supply systems any number of
power supplies with ViP feature can be connected (+)
and (-) in parallel to same bus without need for addi-
tional synchronization
Programmed to work with 18 Ah batteries
Short circuit and overload protection
Lack of mains detection
Low output voltage detection
Broken fuse detection and identification
Detection of power unit failure
Over-voltage protection
Detection of different battery faults
Deep discharge protection of battery
Remote and local battery testing
Tamper security provided (case opening detection)
Built-in real time diagnostic system with fault visualisa-
tion and localisation by LED on PCB
APPLICATIONS
Intruder alarm systems
Social alarm systems
Access control systems
BLOCK
DIAGRAM
EMC filter
Fuse
Rectifier
Energy storage
DC/DC SMPS ViP converter
ViP load sharing
circuitry
Microcontroller
EPS
relay
APS
relay
OUT
relay
EMC filter
SAB
relay
Output circuit:
fuse, protection
Isolation
transformer
To 12 V, 18 Ah battery
DC Output
Potential free fault signalisation relays
230 VAC
N
L
PE
Over
Voltage
Protection
© 2017 Alarmtech www.alarmtech.pl 2 / 4 PSV 1225-18 1716en
1. INSTALLATION
PSV 1225-18 power supply installation and start-up pro-
cedure:
Fix unit in destination place using 4 fixing holes
Place sealed lead acid battery 12 V/18 Ah in battery
chamber
Make connection between left battery (-) and battery
connector using black battery cable
Make connection between right battery (+) and bat-
tery connector using red battery cable
Make appropriate connections between power output
and power receivers
Make required connections between signalling outputs
of PSV 1225-18 unit and cooperating units (outputs
EPS, APS, OUT, SAB, input RBT*)
The socket outlet delivering 230 VAC shall be installed
near the power supply unit and shall be easily accessi-
ble
Make sure that cable delivering 230 VAC to power sup-
ply is disconnected from mains
Connect 230 VAC cable to 230 VAC input in power sup-
ply unit make sure that PE cable is connected to PE
input
Switch on mains delivering energy to power supply -
PSV 1225-18 unit will start automatically delivering
power to the load and monitoring state of PS
12 V battery
18 Ah
+-
L
N
L
N
Fixing hole
Fixing holeFixing hole
Fixing hole
To lid
grounding
point
Mains fuse
0.315 A slow
Case opening and
pry-off detectors
I/O cablesMains cable entry
17... 19V AC
KICK -
ST A RT
-BAT + -12 V+EPS APS OU T
Alar mt ech
SAB -RBD*SAB
PS V12 25
F 2=5AF 1=3. 15A
F2 F1
17... 19V AC
KICK -
ST A RT
-BAT + -12 V+EPS APS OU T
Alar mt ech
SAB -RBD*SAB
PS V12 25
F 2=5AF 1=3. 15A
F2 F1
Output fuse
3.15 A quick
Battery fuse
5 A quick
12 V battery
18 Ah
+-
L
N
Fixing hole
Fixing holeFixing hole
Fixing hole
To lid
grounding
point
Mains fuse
0.315 A slow
Case opening and
pry-off detectors
I/O cablesMains cable entry
17... 19V AC
KICK -
ST A RT
-BAT + -12 V+EPS APS OU T
Alar mt ech
SAB -RBD*SAB
PS V12 25
F 2=5AF 1=3. 15A
F2 F1
Output fuse
3.15 A quick
Battery fuse
5 A quick
© 2017 Alarmtech www.alarmtech.pl 3 / 4 PSV 1225-18 1716en
2. TECHNICAL DESCRIPTION
2.1 Front panel
Power supply unit is equipped with front panel showing actual general state of unit. Three LED’s display shows:
Green LED: mains voltage present unit in EPS mode supplied from mains
Yellow LED: mains voltage missing unit in APS mode supplied from battery
Red LED: fault detected quick visual identification and localisation of failure is possible with help of set of
diagnostic LED’s in power unit
2.2 Internal state monitoring functions in power unit
All monitored states of PS are displayed with help of LED diodes for quick visual identification. The placement of moni-
toring LED is documented in below placed drawings. The meaning of LED colours is following:
Green - normal state, OK
Red - fault detected
Yellow - informative meaning (neutral)
2.3 Jumpers in power unit
Power unit is equipped with 2 jumpers placed on PCB:
Kick-start jumper (default position: open)
Momentary shunt
Kick-start of PS from battery (w/o mains)
Open (default)
Deep Discharge Protection (DDP) of battery enabled
Closed
Deep Discharge Protection (DDP) of battery disabled
LBD (Local Battery Diagnostics) jumper (default position: open)
Momentary shunt
Battery test trigger (30 s test of internal battery resistance)
Open (default)
Battery recharging circuit enabled
Closed
Battery recharging circuit disabled
Unit state OK
Supplied from mains
Battery OK
Output OK
No faults reported
Missing mains
(EPS output triggered)
Supplied from battery
No other faults
PS supplied from mains
Possible fault detected:
APS (battery)
OUT (output)
Missing mains
(EPS output triggered)
Supplied from battery
Possible faults detected:
APS (battery)
OUT (output)
17...19VAC
KICK-
START
-BAT+ -12V+EPS APS OUT
Alarmtech
SAB -RBD*SAB
PSV1225 F2=5AF1=3.15A
F2 F1
Output fault signalling (OUT)
Battery fault signalling (APS)
Mains fault signalling (EPS)
Output fuse
3.15 A quick
Battery fuse
5 A quick
Input voltage OK
Output voltage OK
Battery recharging
enabled
Front panel connection
DC Output
Input AC voltage
To battery
To tamper switches
Fault relays outputs
Remote battery test
KICK START JUMPER
Kick-start from battery (momentary)
Deep Discharge Protection disable (on)
LBD JUMPER
Battery test trigger (momentary)
Battery circuit disable (on)
© 2017 Alarmtech www.alarmtech.pl 4 / 4 PSV 1225-18 1716en
2.4 Inputs and outputs in power unit
Input/Output
Marking
Description
Power output
-12V+
(-) and (+) terminals for power output
Battery pack connection
-BAT+
(-) and (+) terminals for 12 V battery connection
AC voltage input with PE
17..19VAC
AC voltage input from isolation transformer
Mains failure signalling
EPS
Potential free NC opto-relay output signalling EPS fault
Battery failure signalling
APS
Potential free NC opto-relay output signalling APS fault
Output failure signalling
OUT
Potential free NC opto-relay output signalling OUT fault
Remote Battery Diagnostics trigger
-RBD*
Test triggered by momentary shunt between (-) and (*)
Tamper detection signalling
SAB
Potential free NC micro-switch output
3. TECHNICAL SPECIFICATION
INPUT SPECIFICATION
Voltage: 230 VAC nominal, +10% ÷ -15%
Frequency: 50 Hz
Current: 0.2 A at maximal load
Mains fuse: 0.315 A, 5x20 mm type F
OUTPUT SPECIFICATION
Type of Power Supply acc. to EN 50131-6:2008: type A
Security grade acc. to EN 50131-6:2008: grade 2
Nominal output voltage: 13.8 V
Minimal output voltage in battery mode: 10.0 V (in APS mode)
Total maximal current (load and battery recharging): 2.5 A
Total rated output current: 2.2 A
Quiescent current internally consumed in PS: 0.03 A
Maximal output ripple RMS voltage: <5% of nominal output voltage
Output fuse: 3.15 A, 5x20 mm type F
BATTERY
Battery type: 12 V, 18 Ah battery
Battery recharging method: constant current limited voltage
Maximal battery recharging current: 0.25 A
Time to recharge 18 Ah batteries to 80%: 58 h max (< 72 h)
Battery voltage triggering APS fault: 11 V
Battery voltage triggering DDP circuit: 10 V
Output voltage triggering OUTPUT fault: 9 V
Battery fuse: 5 A, 5x20 mm type F
MONITORING OUTPUTS
EPS loss of mains APS battery pack low voltage, battery failure
OUT output voltage low, power unit failure SAB case tampering
Electrical characteristics of monitoring outputs: - Potential free semiconductor relay
for EPS, APS, OUT fault signalling
- Micro-switch for case tampering signaling
Logical characteristics of monitoring signals: Closed state monitored condition not present
Open state monitored condition present
ENVIRONMENT
Environmental Class acc. to EN 50130-5:1998: Class I
Operating temperature and humidity range: +5º C…+40º C, RH to 90%, no condensation
WEIGHT AND DIMENSIONS
Weight without battery: approx. 1.7 kg
Weight with battery (18Ah): approx. 7.2 kg
Dimensions: 230 x 300 x 100 mm (W x H x D)
Compliance:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4