ORiNG TES-3080-M12 Series User manual

Category
Network switches
Type
User manual
Industrial
Management Ethernet Switch
TES-3080-M12 Series Users Manual
Version 1.0
May, 2011.
ORing Industrial Networking Corp.
4F., NO.3, Lane235, Baociao Rd.Sindian City,
Taipei County 23145 Taiwan, R.O.C.
Tel: + 886 2 2918 3036
Fax: + 886 2 2918 3084
Website: www.oring-networking.com
TES-3080-M12 Series User’s Manual
Table of Content
Getting to Know Your Switch........................................................................4
1.1 About the TES-3080-M12 Industrial Switch....................................................................4
1.2 Software Features ..............................................................................................................4
1.3 Hardware Features.............................................................................................................5
Hardware Installation.....................................................................................6
2.1 Wall Mounting Installation..................................................................................................6
2.1.1 Mount TES-3080-M12 on the wall...................................................................................6
Hardware Overview........................................................................................0
3.1 Front Panel ..........................................................................................................................0
3.2 Front Panel LEDs ...............................................................................................................2
3.3 Bottom Panel..................................................................................錯誤! 尚未定義書籤。
Cables .............................................................................................................3
4.1 Ethernet Cables ..................................................................................................................3
4.1.1 100BASE-TX/10BASE-T Pin Assignments.....................................................................3
4.2 Console Cable.....................................................................................................................3
WEB Management..........................................................................................4
5.1 Configuration by Web Browser .........................................................................................4
5.1.1 About Web-based Management........................................................................................4
5.1.2 System Information ..........................................................................................................6
5.1.3 Front Panel........................................................................................................................6
5.1.4 Basic setting......................................................................................................................7
5.1.4.1 Switch Setting .........................................................................................................7
5.1.4.2 Admin Password .....................................................................................................8
5.1.4.3 IP Setting.................................................................................................................8
5.1.4.4 Time Setting............................................................................................................9
5.1.4.5 LLDP.....................................................................................................................12
5.1.4.6 Auto Provision ......................................................................................................13
5.1.4.7 Backup & Restore.................................................................................................13
ORing Industrial Networking Corp 1
TES-3080-M12 Series User’s Manual
5.1.4.8 Upgrade Firmware ................................................................................................14
5.1.5 DHCP Server..................................................................................................................14
5.1.5.1 DHCP Server – Setting..........................................................................................14
5.1.5.2 DHCP Server – Client List....................................................................................15
5.1.5.3 DHCP Server – Port and IP bindings ....................................................................16
5.1.6 Port Setting.....................................................................................................................16
5.1.6.1 Port Control...........................................................................................................16
5.1.6.2 Port Status.............................................................................................................17
5.1.6.3 Port Alias...............................................................................................................17
5.1.6.4 Rate Limit .............................................................................................................18
5.1.6.5 Port Trunk .............................................................................................................19
5.1.7 Redundancy....................................................................................................................20
5.1.7.1 O-Ring...................................................................................................................20
5.1.7.2 Open-Ring.............................................................................................................21
5.1.7.3 O-RSTP.................................................................................................................23
5.1.7.4 RSTP.....................................................................................................................24
5.1.7.5 MSTP....................................................................................................................26
5.1.8 VLAN.............................................................................................................................30
5.1.8.1 VLAN Setting .......................................................................................................31
5.1.8.2 VLAN Setting – Port Based..................................................................................32
5.1.9 SNMP.............................................................................................................................34
5.1.9.1 SNMPAgent Setting ..........................................................................................34
5.1.9.2 SNMPTrap Setting ............................................................................................35
5.1.10 Traffic Prioritization...................................................................................................36
5.1.11 Multicast ....................................................................................................................40
5.1.11.1 IGMP Snooping.....................................................................................................40
5.1.11.2 Multicast Filter......................................................................................................40
5.1.12 Security......................................................................................................................41
5.1.12.1 IP Security.............................................................................................................42
5.1.12.2 Port Security..........................................................................................................43
5.1.12.3 MAC Blacklist ......................................................................................................43
5.1.12.4 802.1x....................................................................................................................44
5.1.13 Warning......................................................................................................................47
5.1.13.1 Fault Alarm ...........................................................................................................47
5.1.13.2 System Alarm........................................................................................................48
5.1.14 Monitor and Diag.......................................................................................................52
5.1.14.1 MAC Address Table..............................................................................................52
ORing Industrial Networking Corp 2
TES-3080-M12 Series User’s Manual
5.1.14.2 MAC Address Aging.............................................................................................52
5.1.14.3 Port Statistics.........................................................................................................53
5.1.14.4 Port Monitoring.....................................................................................................54
5.1.14.5 System Event Log.................................................................................................55
5.1.14.6 Ping.......................................................................................................................56
5.1.15 Save Configuration ....................................................................................................56
5.1.16 Factory Default..........................................................................................................57
5.1.17 System Reboot...........................................................................................................57
Command Line Interface Management ......................................................58
6.1 About CLI Management.................................................................................................58
6.2 Commands Set List—System Commands Set................................................................63
6.3 Commands Set List—Port Commands Set.....................................................................65
6.4 Commands Set List—Trunk command set.....................................................................68
6.5 Commands Set List—VLAN command set....................................................................69
6.6 Commands Set List—Spanning Tree command set........................................................70
6.7 Commands Set List—QoS command set........................................................................72
6.8 Commands Set List—IGMP command set.....................................................................73
6.9 Commands Set List—MAC/Filter Table command set ..................................................74
6.10 Commands Set List—SNMP command set....................................................................74
6.11 Commands Set List—Port Mirroring command set .......................................................75
6.12 Commands Set List—802.1x command set....................................................................76
6.13 Commands Set List—TFTP command set......................................................................78
6.14 Commands Set List—SYSLOG, SMTP, EVENT command set.....................................79
6.15 Commands Set List—SNTP command set.....................................................................81
6.16 Commands Set List—O-Ring command set...................................................................82
Technical Specifications .............................................................................83
ORing Industrial Networking Corp 3
TES-3080-M12 Series User’s Manual
Getting to Know Your Switch
1.1 About the TES-3080-M12 Industrial Switch
ORing’s Transporter™ series managed Ethernet switches are designed for industrial
applications, such as rolling stock, vehicle, and railway applications. The TES-3080-M12
series are managed Redundant Ring Ethernet switch with 8x10/100Base-T(X) ports which is
compliant with EN50155 request. With completely support of Ethernet Redundancy protocol,
O-Ring (recovery time < 10ms over 250 units of connection), Open-Ring, O-RSTP and
MSTP/RSTP/STP (IEEE 802.1s/w/D) can protect your mission-critical applications from
network interruptions or temporary malfunctions with its fast recovery technology. It is
specifically designed for the toughest industrial environments. TES-3080-M12 series
EN50155 Ethernet switch use M12 connectors to ensure tight, robust connections, and
guarantee reliable operation against environmental disturbances, such as vibration and shock.
Another Open-Ring technology is also supported which can applied for other vendor's
proprietary ring. TES-3080-M12 series can be managed centralized and convenient by a
powerful windows utility ~ Open-Vision. In addition, the wide operating temperature range
from -40 oC to 70oC can satisfy most of operating environment. Therefore, these switches are
one of the most reliable choices for rolling stock and highly-managed Ethernet application.
1.2 Software Features
Leading EN50155-compliant Ethernet switch for rolling stock application
World’s fastest Redundant Ethernet Ring (Recovery time < 10ms over 250 units
connection)
Open-Ring support the other vendor’s ring technology in open architecture
O-RSTP support applications with complex topology
STP/RSTP/MSTP supported
Support PTP Client (Precision Time Protocol) clock synchronization
Supports SNMPv1/v2c/v3 & RMON & Port base/802.1Q VLAN Network Management
RMON for traffic monitoring
Support LLDP protocol
Port lock to prevent access from unauthorized MAC address Enable/disable ports, MAC
based port security
Event notification through Syslog, Email, SNMP trap, and Relay output
VLAN (802.1Q ) to segregate and secure network traffic
Windows utility (Open-Vision) support centralized management and configurable by
ORing Industrial Networking Corp 4
TES-3080-M12 Series User’s Manual
Web-based ,Telnet, and Console (CLI)
M12 connectors to guarantee reliable operation against environmental disturbances
Wall mounting enabled
1.3 Hardware Features
Redundant dual DC power inputs
Wide Operating Temperature : -40 to 70oC
Storage Temperature: -40 to 85oC
Operating Humidity: 5% to 95%, non-condensing
Casing: IP-40
8 x 10/100Base-T(X) Ethernet port
Console Port
Dimensions (W x D x H) : 125 mm(W)x 86.3 mm( D )x 196 mm(H)
ORing Industrial Networking Corp 5
TES-3080-M12 Series User’s Manual
Hardware Installation
2.1 Wall Mounting Installation
Each switch has another installation method for users to fix the switch. A wall mount panel
can be found in the package. The following steps show how to mount the switch on the wall.
2.1.1 Mount TES-3080-M12 series on the wall
ORing Industrial Networking Corp 6
TES-3080-M12 Series User’s Manual
ORing Industrial Networking Corp 7
The screws specification shows in the following two pictures. In order to prevent switches
from any damage, the screws should not larger than the size that used in TES-3080-M12
series switches.
Pozidrive
Hardware Overview
3.1 Front Panel
The following table describes the labels that stick on the TES-3080-M12 series.
Port Description
10/100 RJ-45 fast
Ethernet ports
10/100 Base-T(X) Ports on M12 (D-coding) Auto MDI/MDIX
auto-negotiation.
Default Setting :
Speed: auto
Duplex: auto
Flow control : disable
Console RS-232 in M12 connector. Baud rate setting: 9600bps, 8, N, 1
Reset Push reset button 2 to 3 seconds to reset the switch.
Push reset button 5 seconds to reset the switch into Factory
Default.
TES-3080-M12 Series User’s Manual
TES-3080-M12
1. Relay output to carry capacity of 3A at 24VDC on M12 connector (D-coding)
2. 10/100Base-T(X) Ethernet ports on M12.
3. LED for Ethernet ports Link/ ACT status.
4. LED for Ethernet ports Duplex / Collision status.
5. Power :Dual 12~48VDC on 5-pin M23 connector .
6. Console Port : RS-232 in M12 connector. Baud rate setting: 9600bps, 8, N, 1
7. Status LED
LED for PWR1. When the PWR1 links, the green led will be light on.
LED for PWR2. When the PWR2 links, the green led will be light on.
LED for R.M (Ring master). When the LED light on, it means that the switch is the ring
master of O-Ring.
LED for Ring. When the led light on, it means the O-Ring is activated.
LED for Fault Relay. When the fault occurs, the amber LED will be light on.
ORing Industrial Networking Corp 1
TES-3080-M12 Series User’s Manual
3.2 Front Panel LEDs
LED Color Status Description
PW1 Green On DC power module 1 activated.
PW2 Green On DC power module 2 activated.
R.M Green On O-Ring Master.
On O-Ring enabled.
Slowly blinking O-Ring topology has problem
Ring Green
Fast blinking O-Ring work normally.
Fault Amber On Fault relay. Power failure or
Port down/fail.
10/100Base-T(X) Fast Ethernet ports
On Port link up.
LNK / ACT Green
Blinking Data transmitted.
On Port works under full-duplex.
Off Port works under half-duplex.
Duplex /
Collision Amber
Blinking Data transmitted.
3.3 Power Inputs
The power components is shown as below:
1. Dual 12~48VDC on 5-pin M23 connector
ORing Industrial Networking Corp 2
TES-3080-M12 Series User’s Manual
Cables
4.1 Ethernet Cables
4.1.1 100BASE-TX/10BASE-T Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 and 3 are used for transmitting data, and pins
2 and 4 are used for receiving data.
Pin Number Assignment
1 Tx +
2 Rx -
3 Tx -
4 Rx +
4.2 Console Cable
TES-3080-M12 series switches can be management by console port. The DB-9 to M12
cable can be found in the package. You can connect them to PC via a RS-232 cable with
DB-9 female connector and the other end (M12 connector) connects to console port of switch.
ORing Industrial Networking Corp 3
TES-3080-M12 Series User’s Manual
WEB Management
5.1 Configuration by Web Browser
This section introduces the configuration by Web browser.
5.1.1 About Web-based Management
An embedded HTML web site resides in flash memory on the CPU board. It contains
advanced management features and allows you to manage the switch from anywhere on the
network through a standard web browser such as Microsoft Internet Explorer.
The Web-Based Management function supports Internet Explorer 5.0 or later. It is based
on Java Applets with an aim to reduce network bandwidth consumption, enhance access
speed and present an easy viewing screen.
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. You need to explicitly modify
the browser setting in order to enable Java Applets to use network ports.
Preparing for Web Management
The default value is as below:
IP Address: 192.168.10.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.10.254
User Name: admin
Password: admin
System Login
1. Launch the Internet Explorer.
2. Type http:// and the IP address of the switch. Press “Enter”.
ORing Industrial Networking Corp 4
TES-3080-M12 Series User’s Manual
3. The login screen appears.
4. Key in the username and password. The default username and password is
admin”.
5. Click Enter” or ”OK” button, then the main interface of the Web-based
management appears.
Login screen
Main Interface
Main interface
ORing Industrial Networking Corp 5
TES-3080-M12 Series User’s Manual
5.1.2 System Information
System Information interface
System Information
The system information will display the configuration of Basic Setting / Switch Setting page.
Enable Location Alert
When click , PWR1, and PWR2 LEDs of the switch will start to
flash together, and click , the LEDs will stop flashing.
5.1.3 Front Panel
Show the panel of TES-3080-M12 series. Click “Close” to close panel on web.
ORing Industrial Networking Corp 6
TES-3080-M12 Series User’s Manual
5.1.4 Basic setting
5.1.4.1 Switch Setting
Switch setting interface
The following table describes the labels in this screen.
Label Description
System Name Assign the name of switch. The maximum length is 64 bytes
System Description Display the description of switch.
System Location Assign the switch physical location. The maximum length is 64
bytes
System Contact Enter the name of contact person or organization
System OID Display the switch’s OID information
Firmware Version Display the switch’s firmware version
Kernel Version Display the kernel software version
MAC Address Display the unique hardware address assigned by manufacturer
(default)
ORing Industrial Networking Corp 7
TES-3080-M12 Series User’s Manual
5.1.4.2 Admin Password
Change web management login username and password for the management security
issue
Admin Password interface
The following table describes the labels in this screen.
Label Description
User name Key in the new username (The default is “admin”)
New Password Key in the new password (The default is “admin”)
Confirm password Re-type the new password.
Apply Click “Apply” to activate the configurations.
5.1.4.3 IP Setting
You can configure the IP Settings and DHCP client function through IP configuration.
IP Configuration interface
ORing Industrial Networking Corp 8
TES-3080-M12 Series User’s Manual
The following table describes the labels in this screen.
Label Description
DHCP Client To enable or disable the DHCP client function. When DHCP
client function is enabling, the switch will be assigned the IP
address from the network DHCP server. The default IP address
will be replaced by the IP address which the DHCP server has
assigned. After clicking Apply” button, a popup dialog shows
up to inform when the DHCP client is enabling. The current IP
will lose and you should find a new IP on the DHCP server.
IP Address Assign the IP address that the network is using. If DHCP client
function is enabling, you do not need to assign the IP address.
The network DHCP server will assign the IP address for the
switch and it will be display in this column. The default IP is
192.168.10.1
Subnet Mask Assign the subnet mask of the IP address. If DHCP client
function is enabling, you do not need to assign the subnet mask
Gateway Assign the network gateway for the switch. The default gateway
is 192.168.10.254
DNS1 Assign the primary DNS IP address
DNS2 Assign the secondary DNS IP address
Apply Click “Apply” to activate the configurations.
5.1.4.4 Time Setting
SNTP
The SNTP (Simple Network Time Protocol) settings allow you to synchronize switch clocks
in the Internet.
SNTP Configuration interface
ORing Industrial Networking Corp 9
TES-3080-M12 Series User’s Manual
The following table describes the labels in this screen.
Label Description
SNTP Client Enable or disable SNTP function to get the time from the SNTP
server.
Daylight Saving Time Enable or disable daylight saving time function. When daylight
saving time is enabling, you need to configure the daylight saving
time period.
UTC Time zone Set the switch location time zone. The following table lists the
different location time zone for your reference.
Local Time Zone Conversion from UTC Time at 12:00 UTC
November Time Zone - 1 hour 11 am
Oscar Time Zone -2 hours 10 am
ADT - Atlantic Daylight -3 hours 9 am
AST - Atlantic Standard
EDT - Eastern Daylight -4 hours 8 am
EST - Eastern Standard
CDT - Central Daylight -5 hours 7 am
CST - Central Standard
MDT - Mountain Daylight -6 hours 6 am
MST - Mountain Standard
PDT - Pacific Daylight -7 hours 5 am
PST - Pacific Standard
ADT - Alaskan Daylight -8 hours 4 am
ALA - Alaskan Standard -9 hours 3 am
HAW - Hawaiian Standard -10 hours 2 am
Nome, Alaska -11 hours 1 am
ORing Industrial Networking Corp 10
TES-3080-M12 Series User’s Manual
CET - Central European
FWT - French Winter
MET - Middle European
MEWT - Middle European
Winter
SWT - Swedish Winter
+1 hour 1 pm
EET - Eastern European,
USSR Zone 1 +2 hours 2 pm
BT - Baghdad, USSR Zone
2 +3 hours 3 pm
ZP4 - USSR Zone 3 +4 hours 4 pm
ZP5 - USSR Zone 4 +5 hours 5 pm
ZP6 - USSR Zone 5 +6 hours 6 pm
WAST - West Australian
Standard +7 hours 7 pm
CCT - China Coast, USSR
Zone 7 +8 hours 8 pm
JST - Japan Standard,
USSR Zone 8 +9 hours 9 pm
EAST - East Australian
Standard GST
Guam Standard, USSR
Zone 9
+10 hours 10 pm
IDLE - International Date
Line
NZST - New Zealand
Standard
NZT - New Zealand
+12 hours Midnight
Label Description
SNTP Sever IP
Address Set the SNTP server IP address.
Daylight Saving Set up the Daylight Saving beginning time and Daylight Saving
ORing Industrial Networking Corp 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93

ORiNG TES-3080-M12 Series User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI