VICTORY II VHS Series

Slant/Fin VICTORY II VHS Series User manual

  • Hello! I am an AI chatbot trained to assist you with the Slant/Fin VICTORY II VHS Series User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
VICTORY VSPH SERIES
©Slant/Fin Corp. 2007
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
DIMENSIONS – GAS BOILERS
®
Dimensions VSPH-60 VSPH-90 VSPH-120 VSPH-150 VSPH-180
“A” 1118"1418"1718"2018"2318"
“B” 1738"20
38"23
38"26
38"29
38"
12"
6"
6"
(DOTTED PIPING
BY OTHERS)
Pressure relief
valve
112"FPT
supply
Install manual main
shutoff valve 5' above
floor when required by
local code
34"to air eliminating
system
Dotted gas piping
byothers
3" dia.
vent
connector
Press/temp
gauge
Junction
box
112"return tapping
114"cir. flange
Vent
connector
28
1
2
"
(See note)
2834"
(See note)
34"Drain
2518"
(See note)
A
Jacket
B
Sediment
trap
required
3012"
(See note)
NOTE: Height dimensions increase by 112"and
depth increases to 2812"when combustible floor
kit is used.
Supply water tapping 112"
Circulator returnflange* 114"
Gas tapping, natural or propane 12"
sAL 29-4C is a registered trademark of Allegheny Ludlum Corp.
*When not equipped with circulator,boiler 112"returntapping.
12"
6"
6"
12"
*2"
6"
*2"
*6" for
enclosed
LEFT END VIEW FRONT VIEW RIGHT END VIEW
Minimum clearance
dimensions
/