Panasonic WHSHF09D3E8 Operating instructions

Type
Operating instructions

This manual is also suitable for

Model br.
Unutarnja jedinica
WH-SHF09D3E8
WH-SHF12D9E8
HRVATSKI 2 ~ 9
Prije rukovanja uređajem pažljivo pročitajte ove upute za uporabu i sačuvajte ih za buduću uporabu.
Prije korištenja uređaja provjerite je li ovlašteni dobavljač ispravno proveo instalaciju, precizno prateći sljedeće upute za
instalaciju.
F568675
© Panasonic Appliances Air-Conditioning Malaysia
Sdn. Bhd. 2012. Neovlaštenim kopiranjem i
distribucijom kršite zakon.
Vanjska jedinica
WH-UH09DE8
WH-UH12DE8
F567972
Operating Instructions
Air-to-Water Heatpump
Model No.
Indoor Unit
Outdoor Unit
WH-SXF09D3E5 WH-UX09DE5
WH-SXF12D6E5 WH-UX12DE5
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011.
Unauthorized copying and distribution is a violation
of law.
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and
precisely following the installation instructions given.
2 ~ 9
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé
et dans le strict respect des consignes d’installation fournies.
10 ~ 17
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
18 ~ 25
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
26 ~ 33
ITALIANO
Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi
fare riferimento in futuro.
Prima di far funzionare l’unità, assicurarsi che l’installazione sia stata eseguita correttamente da un rivenditore
autorizzato e seguendo precisamente le istruzioni date per l’installazione
34 ~ 41
NEDERLANDS
Lees voor u het apparaat gebruikt deze gebruiksaanwijzing grondig en bewaar deze voor toekomstig gebruik.
Controleer, voor u de unit in gebruik neemt, dat de installatie goed is uitgevoerd door een of ciële dealer en dat dat
nauwkeurig is gedaan volgens de verstrekte instructies voor de installatie.
42 ~ 49
PORTUGUÊS
Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
Antes de colocar a unidade em funcionamento, ceritifque-se que a instalação foi feita correctamente por um
fornecedor autorizado e que seguiu com precisão as instruções de instalação dadas.
50 ~ 57
EΛΛΗΝΙΚΆ
Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά.
Πριν θέσετε σε λειτουργία τη μονάδα, βεβαιωθείτε ότι η εγκατάσταση έχει διεξαχθεί κανονικά από εξουσιοδοτημένο
αντιπρόσωπο, ο οποίος έχει ακολουθήσει σωστά και πιστά τις δοθείσες οδηγίες.
58 ~ 65
БЪЛГАРСКИ
Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки.
Преди да използвате устройството се уверете, че монтажът е извършен правилно и прецизно от оторизиран дилър,
като са спазвани инструкциите за монтаж.
66 ~73
0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF
/
ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHUFRISAT SUN
SOLAR REMOTE
NOT AVAILABLE
2 3 4 5 6
ON
OFF
F567972
Operating Instructions
Air-to-Water Heatpump
Model No.
Indoor Unit
Outdoor Unit
WH-SXF09D3E5 WH-UX09DE5
WH-SXF12D6E5 WH-UX12DE5
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011.
Unauthorized copying and distribution is a violation
of law.
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and
precisely following the installation instructions given.
2 ~ 9
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé
et dans le strict respect des consignes d’installation fournies.
10 ~ 17
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
18 ~ 25
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
26 ~ 33
ITALIANO
Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi
fare riferimento in futuro.
Prima di far funzionare l’unità, assicurarsi che l’installazione sia stata eseguita correttamente da un rivenditore
autorizzato e seguendo precisamente le istruzioni date per l’installazione
34 ~ 41
NEDERLANDS
Lees voor u het apparaat gebruikt deze gebruiksaanwijzing grondig en bewaar deze voor toekomstig gebruik.
Controleer, voor u de unit in gebruik neemt, dat de installatie goed is uitgevoerd door een of ciële dealer en dat dat
nauwkeurig is gedaan volgens de verstrekte instructies voor de installatie.
42 ~ 49
PORTUGUÊS
Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
Antes de colocar a unidade em funcionamento, ceritifque-se que a instalação foi feita correctamente por um
fornecedor autorizado e que seguiu com precisão as instruções de instalação dadas.
50 ~ 57
EΛΛΗΝΙΚΆ
Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά.
Πριν θέσετε σε λειτουργία τη μονάδα, βεβαιωθείτε ότι η εγκατάσταση έχει διεξαχθεί κανονικά από εξουσιοδοτημένο
αντιπρόσωπο, ο οποίος έχει ακολουθήσει σωστά και πιστά τις δοθείσες οδηγίες.
58 ~ 65
БЪЛГАРСКИ
Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки.
Преди да използвате устройството се уверете, че монтажът е извършен правилно и прецизно от оторизиран дилър,
като са спазвани инструкциите за монтаж.
66 ~73
0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF
/
ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHUFRISAT SUN
SOLAR REMOTE
NOT AVAILABLE
2 3 4 5 6
ON
OFF
Upute za uporabu
Toplinska crpka zrak-voda
2
Panasonicova
toplinska crpka zrak-voda
odijeljeni je sustav koji
se sastoji samo od vanjske jedinice i unutarnje jedinice. Sustav je
osmišljen za korištenje u kombinaciji s Panasonicovim spremnikom. U
slučaju da se uz Panasonicov
sustav toplinske crpke zrak-voda
koristi spremnik koji nije Panasonicov, Panasonic ne može jamčiti ni
pouzdan rad niti pouzdanost sustava.
U ovom je priručniku opisano kako se koristi sustav toplinske crpke
samo između vanjske i unutarnje jedinice.
Detalje o radu ostalih dijelova, kao što je spremnik za vodu, radijator,
termostat i podni sustav, potražite u korisničkim priručnicima
proizvođača te opreme.
Radi sprečavanja samoozljeđivanja, ozljeđivanja drugih osoba ili štete na
imovini, pridržavajte se sljedećeg.
Neispravne radnje koje su rezultat nepridržavanja ovih uputa mogu izazvati
ozlijede ili štetu koja po ozbiljnosti može biti:
Zahvaljujemo vam na kupnji
Panasonicova proizvoda.
Ilustracije navedene u ovim uputama služe
samo radi objašnjenja i mogu se razlikovati od
stvarnog uređaja. Podlne su promjenama bez
prethodne obavijesti radi budućih poboljšanja.
Temperatura izlaza za
vodu (°C)
Unutarnji
GRIJANJE
Maks. 65
Min. 25
Temperatura okoline
(°C)
Vanjski
GRIJANJE
Maks. 35
Min. -20
NAPOMENA:
Kada je vanjska temperatura iznad
temperaturnog raspona, kapacitet grijanja
značajno će se smanjiti i vanjska će jedinica
možda prestati s radom kako bi se izvršila
sigurnosna kontrola.
Uređaj će se automatski ponovno pokrenuti
kratko nakon što se unutarnja temperatura
vrati u granice.
U slučaju kad je vanjska temperatura iznimno
niska, potreban je rad pomoćnoga grijača.
SADRŽAJ
NAPOMENA
UVJETI RADA
MJERE OPREZA
2~3
UPRAVLJAČKA PLOČA
4~7
UNUTARNJA JEDINICA
8
U SLUČAJU PROBLEMA
9
INFORMACIJE
10
MJERE OPREZA
Ovaj znak upozorava na
smrtonosne ili ozbiljne ozljede.
Ovaj znak oznava mognost
ozljede ili oštećenja imovine.
Upute koje je potrebno slijediti podijeljene su prema sljedećim simbolima:
Ovaj simbol označava radnju
koja je ZABRANJENA.
Ovi simboli predstavljaju
radnju koja je OBAVEZNA.
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
UPOZORENJE
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
OPREZ
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
VANJSKA JEDINICA I UNUTARNJA JEDINICA
Ovim uređajem ne smiju rukovati osobe (uključujući djecu) sa
smanjenim zičkim, osjetilnim ili mentalnim sposobnostima ili
s nedovoljnim iskustvom i znanjem, osim ako se takve osobe
nalaze pod nadzorom ili ih u uporabu ovoga uređaja upućuju
osobe odgovorne za njihovu sigurnost. Nadgledajte djecu i
nemojte im dopustiti da se igraju ovim uređajem.
Obratite se ovlaštenom dobavljaču ili stručnjaku za čišćenje
unutarnjih dijelova, popravke, instalaciju, uklanjanje i ponovnu
instalaciju uređaja. Neispravna instalacija i rukovanje mogu
dovesti do curenja, električnog udara ili požara.
Savjetujte se s ovlaštenim dobavljačem ili stručnjakom o
uporabi navedene vrste rashladnog sredstva. Uporaba
rashladnog sredstva osim navedene vrste može izazvati
oštećenje proizvoda, eksploziju i ozljedu itd.
Nemojte postavljati uređaj na mjesto na kojem postoji
opasnost od eksplozije ili može doći do zapaljenja. Moglo bi
doći do požara.
Ne gurajte prste ili druge predmete u unutarnju
ili vanjsku jedinicu, dijelovi koji se rotiraju mogu
izazvati ozljedu.
Ne dirajte vanjsku jedinicu kada sijeva da ne bi došlo do
električnog udara.
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
UPOZORENJE
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
3
HRVATSKI
NAPAJANJE
Nemojte sjedati ili stajati na
uređaj, možete slučajno pasti.
Nemojte postavljati unutarnju jedinicu u
vanjski prostor. Predviđena je samo za
instalaciju u unutarnji prostor.
NAPAJANJE
Da ne bi došlo do pretjeranog
zagrijavanja ili vatre, nemojte
koristiti modicirani kabel,
produžni kabel, dupli kabel ili
nepoznati kabel.
Sprečavanje pregrijavanja, vatre ili električnog
udara:
Nemojte ovaj uređaj spajati na istu utičnicu
s nekom drugom opremom.
Ne dirajte uređaj mokrim rukama.
Nemojte previše rastegnuti kabel za napajanje.
Ako je kabel napajanja oštećen, mora ga
zamijeniti proizvođač, serviser proizvođača
ili slično kvalicirane osobe da bi se izbjegle
moguće opasnosti.
Ovaj je uređaj opremljen sklopkom Residue
Current Circuit Breaker (RCCB). Snažno
preporučujemo da provjerite rad osigurača
RCCB nakon što ga instalirate te periodički,
nakon što ovlašteni dobavljač provede
servisiranje ili održavanje, kako biste
se uvjerili u ispravni rad. U suprotnome,
neispravan rad može izazvati električni udar.
Izričito preporučujemo instaliranje sklopke na
diferencijalnu struju (RCD) na lokaciji da bi se
spriječio električni udar ili požar.
Prestanite koristiti uređaj kada dođe do
poremećaja u radu/kvara i isključite mrežni utikač
ili isključite napajanje i strujno-ztitnu sklopku.
(Opasnost od dima/vatre/električnog udara)
Primjeri nepravilnosti/kvara
Sklopka RCCB se sama isključuje.
Za vrijeme rada uređaja iz njega se širi miris
paljevine, neobični zvukovi ili vibracije.
Vruća voda se izlijeva iz uređaja.
Odmah se obratite svom lokalnom dobavljaču
radi održavanja/popravka.
Preporučuje se nošenje rukavica tijekom
servisiranja ili održavanja uređaja radi
izbjegavanja opasnosti.
Ova oprema mora biti uzemljena da bi se
spriječio strujni udar ili vatra.
Spriječite strujni udar tako da isključite
napajanje i iskopčajte:
Prije čišćenja ili servisiranja.
Dugog nekorištenja.
Uređaj služi za višestruku upotrebu. Svi strujni
krugovi trebaju biti isključeni prije nego što
pristupite priključcima unutarnje jedinice kako
biste spriječili strujni udar, opekline ili smrtne
ozljede.
VANJSKA JEDINICA I UNUTARNJA JEDINICA
Vanjsku jedinicu ne perite vodom, benzinom,
razrjeđivačom ili erozivnim puderom.
Nemojte postavljati uređaj blizu zapaljive
opreme ili u kupaonici. Može doći do
električnog udara ili vatre.
Ne dirajte cijev za ispust vode na unutarnjoj
jedinici za vrijeme rada.
Nemojte stavljati nikakve predmete na uređaj ili
ispod njega.
Ne dirajte oštro aluminijsko rebro,
oštri vas dijelovi mogu ozlijediti.
Nemojte koristiti sustav tijekom sterilizacije.
Tako ćete spriječiti isparavanje ili pregrijavanje
tijekom tuširanja.
Provjerite je li odvodna cijev pravilno spojena.
Može doći do curenja.
Nakon duljeg razdoblja uporabe pazite
da rešetka na koju je uređaj montiran ne
propadne kako uređaj ne bi pao.
Postavke polja sterilizacijske funkcije mora
kongurirati ovlašteni dobavljač u skladu s
lokalnim zakonima i propisima.
UPRAVLJAČKA PLOČA
Pazite da u upravljačku plu ne dospije tekina.
Može doći do električnog udara ili vatre.
Nemojte pritiskati gumbe na upravljačkoj ploči
tvrdim, zašiljenim predmetima. Može doći do
oštećenja uređaja
Unutarnju jedinicu ne perite vodom, benzinom,
razrjeđivačom ili erozivnim puderom.
Nemojte sami pokušavati pregledavati i
servisirati upravljačku ploču. Posavjetujte
se s ovlaštenim dobavljačem. Neispravno
rukovanje može uzrokovati povrede.
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
UPOZORENJE OPREZ
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
ENGLISH
5
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment in front of
the air ow outlet to avoid re propagation.
Do not expose plants or pet directly to air ow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
To prevent malfunction or damage of the remote
control:
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
Insert the power plug properly.
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is
switched on for operation.
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the power
supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply with the following.
Incorrect operation due to failure to follow instructions below
may cause harm or damage, the seriousness of which is
classi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classi ed by the following
symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Con rm to authorized dealer or specialist on
usage of speci ed refrigerant type. Using of
refrigerant other than the speci ed type may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you may
fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
To prevent overheating, re or electric shock:
Do not share the same power outlet with other
equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
Do not operate or stop the unit by inserting or
pulling out the power plug.
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Remote
Control
Power
Supply
Indoor
Unit
Outdoor
Unit
/
/
Panel
Power Supply
Floor Heating
Control Panel
Indoor Unit
Shower
Outdoor Unit
Water Tank Unit
Unutarnja
jedinica
Napajanje
Grijanje poda
T
Zaslon
Vanjska jedinica
Upravljačka ploča
Jedinica spremnika
za vodu
4
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
4
CONTROL PANEL
Some functions describe in this manual may not be applicable to your unit.
Consult your nearest authorized dealer for further information.
For normal operation, the
ERROR
RESET
,
FORCE
and
SERVICE
buttons are not in use.
CONTROL PANEL’S DISPLAY
a
Heat Mode OFF/ON Indicator
j
Timer/Clock Setting Display
b
Tank Mode Indicator
k
Outdoor Ambient Temperature Display
c
Quiet Mode Indicator
l
Water Outlet Temperature Display
d
Backup Heater Enabled/Disabled Indicator
m
Backup Heater Actual (OFF/ON) Indicator
e
Force Heater Request OFF/ON Indicator
n
Booster Heater Actual (OFF/ON) Indicator
f
External Thermo Controller Connected Display
o
System Defrost Operation OFF/ON Indicator
g
Operation LED
p
System Setting Mode OFF/ON Indicator
h
Solar Display
q
System Status Check Mode OFF/ON Indicator
i
Caution (Tank Temperature above 60°C) Indicator
r
System Service Mode OFF/ON Indicator
CONTROL PANEL’S BUTTON
1
OFF/ON Button
6
Timer Setting Group Buttons
2
Operation Mode Button
7
Force Heater Mode Button
3
Quiet Operation Button
8
System Service Mode Button
4
Indoor Unit Backup Heater Enabling Button
9
System Status Check Button
5
System Setting Mode Buttons
10
Error Reset Button
HEAT
TANK
QUIET
FORCE
HEATER
OPERATION
BOOSTER
HEATER
ACTUAL
DEFROST
SETTING
STATUS
SERVICE
WATER OUTLET
OFF
/
ON
TIMER OUTDOOR
C
C
C
Open cover for buttons selections.
TIMER OUTDOOR
HEAT
SETTING
STATUS
SERVICE
BOOSTER
QUIET
TANK
DEFROST
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
SERVICEFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
SOLAR REMOTE
2 3 4 5 6
ON
OFF
a
b
c
d
e
f
g
h i
j
k l
m
n
o
p
q
r
1
6
5 10 3
7
8
4
9
2
Notes:
The current day and time need to be set when:
- The power is turned on for the rst time.
- After a long time has elapsed since the power was last turned on.
The current time that has been set will be the standard time for all
the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to con rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
F568253_YS0212-1.indb 4 10-Feb-12 3:52:01 PM
Pokazatelj uključenosti/isključenosti grijanja
Pokazatelj načina spremnika
Pokazatelj tihog načina rada
Pokazatelj omogućenosti/onemogućenosti pomnoga grija
Pokazatelj uključenosti/isključenosti forsiranoga grijanja
Prikaz priključenosti vanjskog termostata
LED svjetlo koje označava rad uređaja
Solarni prikaz
Pokazatelj upozorenja (Temperatura spremnika iznad 60 °C)
Gumb OFF/ON (isključivanje/uključivanje)
Gumb načina rada
Gumb tihog načina rada
Gumb za grijanje pomoćnoga grijača unutarnje jedinice
Gumbi za sistemske postavke
Gumbi za postavljanje brojača
Gumb forsiranog grijanja
Gumb za uslugu sustava
Gumb za provjeru statusa sustava
Gumb za resetiranje radi pogreške
Prikaz postavki brojača/sata
Prikaz vanjske temperature
Prikaz temperature izlaza za vodu
Pokazatelj stvarne uključenosti/isključenosti
pomoćnoga grijača
Pokazatelj stvarne uključenosti/isključenosti
dodatnoga grijača
Pokazatelj uključenosti/isključenosti radnje
odleđivanja sustava
Pokazatelj uključenosti/isključenosti sistemskih postavki
Pokazatelj uključenosti/isključenosti provjere statusa sustava
Pokazatelj uključenosti/isključenosti usluga sustava
Da biste odabrali gumbe, otvorite
poklopac.
ZASLON UPRAVLJAČKE PLOČE
GUMB UPRAVLJAČKE PLOČE
UPRAVLJAČKA PLOČA
Neke od funkcija opisanih u ovom priručniku možda se neće moći primijeniti na vaš uređaj.
Više podataka potražite kod ovlaštenog dobavljača.
Za običan se rad ne koriste gumbi , i .
Napomene:
Ispravni datum i vrijeme potrebno je postaviti kada:
Prvi put uključujete uređaj.
Nakon što je prošlo dugo vremena od posljednjeg
uključivanja uređaja.
Vrijeme koje postavite bit će standardno vrijeme za sve
aktivnosti brojača.
PRIPREMA UPRAVLJAČKE PLOČE
Postavljanje trenutnog datuma i vremena
1. Pritisnite .
2. Pritisnite ili da biste postavili trenutačni datum.
3. Pritisnite da biste potvrdili.
4. Ponovite korake 2 i 3 da biste postavili trenutačno
vrijeme.
5
HRVATSKI
ENGLISH
5
SETTING UP THE SPECIAL FUNCTIONS
After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.
The control panel can be used for multiple installations. Some functions may not be applicable to your unit.
Ensure the operation LED is in OFF condition before setting.
SET
SELECT
CANCEL
SETTING
STATUS
CHECK
1. Press
SET
and
CHECK
simultaneously for 5 seconds to enter special setting mode.
“SETTING” and “STATUS” indicator is ON.
2. Press
or to browse functions.
3. Press
SELECT
to enter function.
4. Press
or to enable YES or disable NO function, or set other options.
5. Press
SET
to con rm.
Set Control Panel’s Display Description
1
External Thermo Controller (YES / NO)
To set external thermo controller connection.
2
HEATER
Indoor Backup Heater Capacity Selection (3kW / 6kW / 9kW)
To reduce the heater power whenever unnecessary. Options vary depending on model.
3
Water System Freeze Prevention Function (YES / NO)
To activate or deactivate water system freeze prevention function when unit is OFF.
4
TANK
Tank Connection (YES / NO)
To set tank connection.
Note: If select “Tank connection” is “NO”, Set 5 ~ 14 are skipped.
5
SOLAR
Solar Priority (YES / NO)
To choose the solar use for water tank heat up.
6
HEAT
Heating Priority (YES / NO)
To choose the room heating as priority during HEAT + TANK mode.
Note: If select “Heating priority” is “YES”, Set 7 ~ 8 are skipped.
7
HEAT
Heating operation Interval Set
To set timer for Heat mode during HEAT + TANK mode (0.5hour ~ 10 hours).
8
TANK
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
9
BOOSTER
Booster Heater Function (YES / NO)
To activate or deactivate tank booster heater function.
Note: If select “Booster heater function” is “NO”, Set 10 is skipped.
10
BOOSTER
Booster Heater Delay Timer Set
To set delay timer for booster heater to ON if water tank temperature is not reached
(20minutes ~ 1hour 35minutes).
Do not use the system during sterilization to prevent scalding or overheat during shower.
The sterilization function eld settings must be con gured by the authorized dealer according to local laws and regulation.
11
Sterilization (YES / NO)
To set sterilization, if required.
Note: If select “Sterilization” is “NO”, set 12 ~ 14 are skipped.
12
Sterilization Day & Time Set
To set timer for sterilization (only once a week, will operate even in standby condition).
13
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
14
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization
function (5minutes ~ 1hour).
F568253_YS0212-1.indb 5 10-Feb-12 3:52:03 PM
1. U isto vrijeme pritisnite i držite 5 sekundi gumbe i da biste unijeli način
posebnih postavki. Uključen je pokazatelj "SETTING" (postavka) i "STATUS" (status).
2. Pritisnite ili da biste pregledali funkcije.
3. Pritisnite da biste unijeli funkcije.
4. Pritisnite ili da biste omogućili funkciju YES (Da) ili onemogućili funkciju NO (Ne)
ili postavili druge mogućnosti.
5. Pritisnite da biste potvrdili.
Postavljanje
Zaslon upravljačke
ploče
Opis
1
Vanjski termostat (YES/NO) (da/ne)
Postavljanje vanjske veze s termostatom
2 GRIJAČ
Odabir kapaciteta unutarnjega pomoćnoga grijača (3 kW/6 kW/9 kW)
Za smanjivanje snage grijača kad god on nije potreban. Mognosti se razlikuju ovisno o modelu.
3
Funkcija sprečavanja zaleđivanja vode u sustavu (YES/NO) (Da/Ne)
Za aktiviranje ili deaktiviranje funkcije sprečavanja zaleđivanja vode u sustavu kad je uređaj isključen.
4 SPREMNIK
Veza sa spremnikom (YES / NO) (Da/Ne)
Postavljanje veze sa spremnikom
Napomena: Ako je u "Veza sa spremnikom" odabrano "NO" (Ne), preskaču se postavke 5 ~ 14
5 SOLARNI
Solarni prioritet (YES / NO)
Odabir solarnog načina zagrijavanja vode iz spremnika s vodom.
6 GRIJANJE
Prioritet grijanja (YES / NO)
Za odabir grijanja sobe kao prioriteta u načinu GRIJANJE + SPREMNIK
Napomena: Ako je u "Prioritet grijanje" odabrano "YES" (Da), preskaču se postavke 7 ~ 8
7 GRIJANJE
Postavljanja intervala zagrijavanja
Postavljanje brojača za način grijanja u načinu HEAT + TANK (0,5 sati ~ 10 sati).
8 SPREMNIK
Postavljanja intervala zagrijavanja za spremnik
Postavljanje brojača za spremnik u načinu HEAT + TANK (5 min do 1 sat i 35 min)
9 DODATNI
Funkcija dodatnoga grijača (YES/NO) (Da/Ne)
Za aktiviranje ili deaktiviranje funkcije spremnika dodatnoga grijača.
Napomena: Ako je u "Funkcija dodatnoga grijača" odabrano "No" (Ne), preskače se postavka 10.
10 DODATNI
Postavljanje brojača vremena s odgodom za dodatni grijač
Za postavljanje brojača s odgodom za uključivanje dodatnog grijača (ON) ako se ne
postigne temperatura spremnika za vodu (20 min ~ do 1 sat i 35 min)
11
Sterilizacija (YES / NO)
Postavljanje sterilizacije, ako je potrebna.
Napomena: Ako je u "Sterilizacija" odabrano "NO" (Ne), preskaču se postavke 12 ~ 14
12
Postavke vremena i datuma sterilizacije
Za postavljanje brojača vremena za sterilizaciju (samo jednom tjedno, radit će u stanju pripravnosti).
13
Postavke temperature na kojoj se provodi sterilizacija
Postavljanje temperature za funkciju sterilizacije (40°C ~ 75°C).
14
Vrijeme trajanja sterilizacije
Postavljanje brojača radi održavanja temperature za grijanje da bi se dovršila funkcija
sterilizacije (5 min ~ 1 sat).
Nemojte koristiti sustav tijekom sterilizacije. Tako ćete spriječiti isparavanje ili pregrijavanje tijekom tuširanja.
Postavke polja sterilizacijske funkcije mora kongurirati ovlašteni dobavljač u skladu s lokalnim zakonima i propisima.
POSTAVLJANJE POSEBNIH FUNKCIJA
Nakon početne instalacije moguće je ručno prilagoditi postavke. Početna postavka ostaje aktivna sve dok je korisnik ne promijeni.
Upravljačku je ploču moguće koristiti za višestruke instalacije. Neke od funkcija možda se neće moći primijeniti na vaš uređaj.
Prije postavljanja postavki uvjerite se da LED svjetlo koje označava uključenost/isključenost uređaja ne svijetli.
6
6
BASIC OPERATION
OFF
/
ON
TO TURN ON OR OFF THE UNIT
When unit is ON, operation LED is lit and the actual
temperature for water outlet and outdoor ambient are
shown on the control panel display.
MODE
TO SELECT OPERATION MODE
HEAT HEAT+TANK TANK
HEAT MODE
- To turn ON or OFF the panel/ oor heating operation.
- In this mode, the outdoor unit will provide heating
capacity to the indoor unit.
HEAT + TANK MODE
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank and indoor unit.
- This operation is not used when the sanitary water
tank is not installed.
TANK MODE
- To turn ON or OFF the sanitary tank operation.
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank.
QUIET
TO ENJOY QUIET ENVIRONMENT
This operation reduces outdoor unit noise. In this
condition, it may cause decrease in heating capacity.
HEATER
TO ENABLE THE BACKUP
HEATER
The backup heater provides extra heating capacity
during cold outdoor temperature and only can operated
at heat mode operation for indoor unit when he was
enabled by pushing this button.
The backup heater will automatically turn ON when the
setting conditions is ful lled.
To disabled the Heater operation manually, press the
respective button again.
STATUS
SEARCH
CHECK
SYSTEM STATUS CHECK MODE
1. Press
CHECK
for 5 seconds to enter STATUS mode.
2. Press
or to check the Water Inlet
Temperature, Tank Temperature, Compressor Running
Frequency or Error History.
Press
C
AN
C
E
L
to exit STATUS mode.
Once STATUS mode is entered, “STATUS”
indicator is ON.
STATUS mode cannot be activated when the
“SETTING” indicator is ON.
It is strongly recommended to contact the nearest
authorized dealer to change the water temperature range.
Using the control panel could set the temperature
range for water outlet temperature and outdoor ambient
temperature.
SYSTEM SETTING MODE
SET
SELECT
CANCEL
SETTING
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
ON
Operation Mode Temperature display
SETTING indicator
Parameter *
1. Press
SET
for 5 seconds to enter “SETTING” mode.
“SETTING” indicator is ON.
2. Press
or to choose a parameter.
3. After selecting the desired parameter, press
SELECT
to enter
the parameter.
4. Press
or to set the desired temperature.
5. Press
SET
again to con rm the setting.
Repeat steps 2 to 5 to set other parameters.
Operation
Mode
Parameter * Description
HEAT
Low outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
High outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
Water outlet set temperature at low outdoor
ambient temperature (25°C ~ 55°C).
HEAT
Water outlet set temperature at high outdoor
ambient temperature (25°C ~ 55°C).
Water Temperature
Outdoor Temperature
HEAT
OFF
Set temperature for turning OFF heating
operation (5°C ~ 35°C).
HEATER
ON
Outdoor ambient set temperature for turning
ON heater operation (-15°C ~ 20°C).
TANK
Sanitary tank set temperature
(40°C ~ 75°C).
WATER TEMPERATURE THERMO SHIFT SETTING
1. Press
SET
within 5 seconds.
Repeat steps 3 to 5 to set the desired shift temperature
(-5°C ~ 5°C).
Notes:
Press
C
AN
C
E
L
or wait 30 seconds to exit “SETTING” mode.
The setting temperature will be stored in the system once
con rm.
“SETTING” mode cannot be activated when the
“PUMPDW” and “STATUS” indicator is ON.
ADVANCE OPERATION
6
BASIC OPERATION
OFF
/
ON
TO TURN ON OR OFF THE UNIT
When unit is ON, operation LED is lit and the actual
temperature for water outlet and outdoor ambient are
shown on the control panel display.
MODE
TO SELECT OPERATION MODE
HEAT HEAT+TANK TANK
HEAT MODE
- To turn ON or OFF the panel/ oor heating operation.
- In this mode, the outdoor unit will provide heating
capacity to the indoor unit.
HEAT + TANK MODE
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank and indoor unit.
- This operation is not used when the sanitary water
tank is not installed.
TANK MODE
- To turn ON or OFF the sanitary tank operation.
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank.
QUIET
TO ENJOY QUIET ENVIRONMENT
This operation reduces outdoor unit noise. In this
condition, it may cause decrease in heating capacity.
HEATER
TO ENABLE THE BACKUP
HEATER
The backup heater provides extra heating capacity
during cold outdoor temperature and only can operated
at heat mode operation for indoor unit when he was
enabled by pushing this button.
The backup heater will automatically turn ON when the
setting conditions is ful lled.
To disabled the Heater operation manually, press the
respective button again.
STATUS
SEARCH
CHECK
SYSTEM STATUS CHECK MODE
1. Press
CHECK
for 5 seconds to enter STATUS mode.
2. Press
or to check the Water Inlet
Temperature, Tank Temperature, Compressor Running
Frequency or Error History.
Press
C
AN
C
E
L
to exit STATUS mode.
Once STATUS mode is entered, “STATUS”
indicator is ON.
STATUS mode cannot be activated when the
“SETTING” indicator is ON.
It is strongly recommended to contact the nearest
authorized dealer to change the water temperature range.
Using the control panel could set the temperature
range for water outlet temperature and outdoor ambient
temperature.
SYSTEM SETTING MODE
SET
SELECT
CANCEL
SETTING
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
ON
Operation Mode Temperature display
SETTING indicator
Parameter *
1. Press
SET
for 5 seconds to enter “SETTING” mode.
“SETTING” indicator is ON.
2. Press
or to choose a parameter.
3. After selecting the desired parameter, press
SELECT
to enter
the parameter.
4. Press
or to set the desired temperature.
5. Press
SET
again to con rm the setting.
Repeat steps 2 to 5 to set other parameters.
Operation
Mode
Parameter * Description
HEAT
Low outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
High outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
Water outlet set temperature at low outdoor
ambient temperature (25°C ~ 55°C).
HEAT
Water outlet set temperature at high outdoor
ambient temperature (25°C ~ 55°C).
Water Temperature
Outdoor Temperature
HEAT
OFF
Set temperature for turning OFF heating
operation (5°C ~ 35°C).
HEATER
ON
Outdoor ambient set temperature for turning
ON heater operation (-15°C ~ 20°C).
TANK
Sanitary tank set temperature
(40°C ~ 75°C).
WATER TEMPERATURE THERMO SHIFT SETTING
1. Press
SET
within 5 seconds.
Repeat steps 3 to 5 to set the desired shift temperature
(-5°C ~ 5°C).
Notes:
Press
C
AN
C
E
L
or wait 30 seconds to exit “SETTING” mode.
The setting temperature will be stored in the system once
con rm.
“SETTING” mode cannot be activated when the
“PUMPDW” and “STATUS” indicator is ON.
ADVANCE OPERATION
6
BASIC OPERATION
OFF
/
ON
TO TURN ON OR OFF THE UNIT
When unit is ON, operation LED is lit and the actual
temperature for water outlet and outdoor ambient are
shown on the control panel display.
MODE
TO SELECT OPERATION MODE
HEAT HEAT+TANK TANK
HEAT MODE
- To turn ON or OFF the panel/ oor heating operation.
- In this mode, the outdoor unit will provide heating
capacity to the indoor unit.
HEAT + TANK MODE
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank and indoor unit.
- This operation is not used when the sanitary water
tank is not installed.
TANK MODE
- To turn ON or OFF the sanitary tank operation.
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank.
QUIET
TO ENJOY QUIET ENVIRONMENT
This operation reduces outdoor unit noise. In this
condition, it may cause decrease in heating capacity.
HEATER
TO ENABLE THE BACKUP
HEATER
The backup heater provides extra heating capacity
during cold outdoor temperature and only can operated
at heat mode operation for indoor unit when he was
enabled by pushing this button.
The backup heater will automatically turn ON when the
setting conditions is ful lled.
To disabled the Heater operation manually, press the
respective button again.
STATUS
SEARCH
CHECK
SYSTEM STATUS CHECK MODE
1. Press
CHECK
for 5 seconds to enter STATUS mode.
2. Press
or to check the Water Inlet
Temperature, Tank Temperature, Compressor Running
Frequency or Error History.
Press
C
AN
C
E
L
to exit STATUS mode.
Once STATUS mode is entered, “STATUS”
indicator is ON.
STATUS mode cannot be activated when the
“SETTING” indicator is ON.
It is strongly recommended to contact the nearest
authorized dealer to change the water temperature range.
Using the control panel could set the temperature
range for water outlet temperature and outdoor ambient
temperature.
SYSTEM SETTING MODE
SET
SELECT
CANCEL
SETTING
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
ON
Operation Mode Temperature display
SETTING indicator
Parameter *
1. Press
SET
for 5 seconds to enter “SETTING” mode.
“SETTING” indicator is ON.
2. Press
or to choose a parameter.
3. After selecting the desired parameter, press
SELECT
to enter
the parameter.
4. Press
or to set the desired temperature.
5. Press
SET
again to con rm the setting.
Repeat steps 2 to 5 to set other parameters.
Operation
Mode
Parameter * Description
HEAT
Low outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
High outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
Water outlet set temperature at low outdoor
ambient temperature (25°C ~ 55°C).
HEAT
Water outlet set temperature at high outdoor
ambient temperature (25°C ~ 55°C).
Water Temperature
Outdoor Temperature
HEAT
OFF
Set temperature for turning OFF heating
operation (5°C ~ 35°C).
HEATER
ON
Outdoor ambient set temperature for turning
ON heater operation (-15°C ~ 20°C).
TANK
Sanitary tank set temperature
(40°C ~ 75°C).
WATER TEMPERATURE THERMO SHIFT SETTING
1. Press
SET
within 5 seconds.
Repeat steps 3 to 5 to set the desired shift temperature
(-5°C ~ 5°C).
Notes:
Press
C
AN
C
E
L
or wait 30 seconds to exit “SETTING” mode.
The setting temperature will be stored in the system once
con rm.
“SETTING” mode cannot be activated when the
“PUMPDW” and “STATUS” indicator is ON.
ADVANCE OPERATION
6
BASIC OPERATION
OFF
/
ON
TO TURN ON OR OFF THE UNIT
When unit is ON, operation LED is lit and the actual
temperature for water outlet and outdoor ambient are
shown on the control panel display.
MODE
TO SELECT OPERATION MODE
HEAT HEAT+TANK TANK
HEAT MODE
- To turn ON or OFF the panel/ oor heating operation.
- In this mode, the outdoor unit will provide heating
capacity to the indoor unit.
HEAT + TANK MODE
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank and indoor unit.
- This operation is not used when the sanitary water
tank is not installed.
TANK MODE
- To turn ON or OFF the sanitary tank operation.
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank.
QUIET
TO ENJOY QUIET ENVIRONMENT
This operation reduces outdoor unit noise. In this
condition, it may cause decrease in heating capacity.
HEATER
TO ENABLE THE BACKUP
HEATER
The backup heater provides extra heating capacity
during cold outdoor temperature and only can operated
at heat mode operation for indoor unit when he was
enabled by pushing this button.
The backup heater will automatically turn ON when the
setting conditions is ful lled.
To disabled the Heater operation manually, press the
respective button again.
STATUS
SEARCH
CHECK
SYSTEM STATUS CHECK MODE
1. Press
CHECK
for 5 seconds to enter STATUS mode.
2. Press
or to check the Water Inlet
Temperature, Tank Temperature, Compressor Running
Frequency or Error History.
Press
C
AN
C
E
L
to exit STATUS mode.
Once STATUS mode is entered, “STATUS”
indicator is ON.
STATUS mode cannot be activated when the
“SETTING” indicator is ON.
It is strongly recommended to contact the nearest
authorized dealer to change the water temperature range.
Using the control panel could set the temperature
range for water outlet temperature and outdoor ambient
temperature.
SYSTEM SETTING MODE
SET
SELECT
CANCEL
SETTING
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
ON
Operation Mode Temperature display
SETTING indicator
Parameter *
1. Press
SET
for 5 seconds to enter “SETTING” mode.
“SETTING” indicator is ON.
2. Press
or to choose a parameter.
3. After selecting the desired parameter, press
SELECT
to enter
the parameter.
4. Press
or to set the desired temperature.
5. Press
SET
again to con rm the setting.
Repeat steps 2 to 5 to set other parameters.
Operation
Mode
Parameter * Description
HEAT
Low outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
High outdoor ambient set temperature
(-15°C ~ 15°C).
HEAT
Water outlet set temperature at low outdoor
ambient temperature (25°C ~ 55°C).
HEAT
Water outlet set temperature at high outdoor
ambient temperature (25°C ~ 55°C).
Water Temperature
Outdoor Temperature
HEAT
OFF
Set temperature for turning OFF heating
operation (5°C ~ 35°C).
HEATER
ON
Outdoor ambient set temperature for turning
ON heater operation (-15°C ~ 20°C).
TANK
Sanitary tank set temperature
(40°C ~ 75°C).
WATER TEMPERATURE THERMO SHIFT SETTING
1. Press
SET
within 5 seconds.
Repeat steps 3 to 5 to set the desired shift temperature
(-5°C ~ 5°C).
Notes:
Press
C
AN
C
E
L
or wait 30 seconds to exit “SETTING” mode.
The setting temperature will be stored in the system once
con rm.
“SETTING” mode cannot be activated when the
“PUMPDW” and “STATUS” indicator is ON.
ADVANCE OPERATION
UKLJUČIVANJE ILI ISKLJUČIVANJE
UREĐAJA
Kada je uređaj uključen, pali se LED lampica, a stvarna
temperatura izlaza za vodu i vanjska temperatura
prikazuju se na upravljačkoj ploči.
ODABIR NAČINA RADA
GRIJANJE
Paljenje i gašenje grijanja poda/panela.
U ovom načinu rada vanjska jedinica pruža kapacitet
za grijanje unutarnjoj jedinici.
GRIJANJE + SPREMNIK
U ovom načinu rada vanjska jedinica pruža kapacitet
za grijanje sanitarnom spremniku i unutarnjoj jedinici.
Radnja se ne koristi kada sanitarni spremnik za vodu
nije instaliran.
SPREMNIK
Paljenje i gašenje rada sanitarnog spremnika.
U ovom načinu rada vanjska jedinica pruža kapacitet
za grijanje sanitarnom spremniku.
UŽIVANJE U TIHOM OKRUŽENJU
Ova radnja smanjuje buku koju stvara vanjska jedinica.
U ovom bi stanju mogla dovesti do smanjenja kapaciteta
grijanja.
OMOGUĆAVANJE POMOĆNOGA
GRIJAČA
Pomoćni grijač pruža dodatni kapacitet za grijanje kod
vrlo niskih vanjskih temperatura i može se koristiti samo
s unutarnjom jedinicom i to u načinu grijanja kad se
pokrene pritiskom na ovaj gumb..
Pomoćni se grijač uključuje automatski kada se
zadovolje uvjeti okoline.
Da biste ručno isključili taj grijač, ponovno pritisnite gumb
za pomoćni grijač.
PROVJERA STATUSA SUSTAVA
1. Pritisnite i držite 5 sekundi gumb da biste unijeli
način STATUS.
2. Pritisnite ili da biste provjerili temperaturu
ulaska vode, temperaturu spremnika, frekvenciju pogona
kompresora ili povijest pogrešaka u radu.
Pritisnite da biste izašli iz načina STATUS.
Kada uključite način STATUS, pali se lampica
pokazatelja uključenosti za "STATUS".
Način STATUS nije moguće aktivirati kada je uključen
pokazatelj "SETTING".
OSNOVNE RADNJE NAPREDNI RAD
Snažno se preporučuje kontaktiranje ovlaštenog
dobavljača da bi se promijenio raspon temperature vode.
Korištenjem upravljačke ploče moguće je postaviti raspon
temperature za izlaz za vodu i vanjsku okolinu.
NAČIN PODEŠENJA SUSTAVA
1. Pritisnite i držite 5 sekundi gumb da biste unijeli način
"SETTING". Uključen je pokazatelj "SETTING" (postavka).
2. Pritisnite ili da biste odabrali parametar.
3. Nakon što odaberete željeni parametar, pritisnite da
biste unijeli parametar.
4. Pritisnite ili da biste postavili željenu temperaturu.
5. Ponovno pritisnite da biste potvrdili postavku.
Ponovite korake od 2 do 5 da biste postavili druge parametre.
Način
rada
Parametar * Opis
GRIJANJE
Postavljena niska vanjska temperatura
(-15 °C ~ 15 °C).
GRIJANJE
Postavljena visoka vanjska temperatura
(-15 °C ~ 15 °C).
GRIJANJE
Postavljena temperatura izlaza za vodu pri
niskoj vanjskoj temperaturi (25°C ~ 55°C).
GRIJANJE
Postavljena temperatura izlaza za vodu pri
visokoj vanjskoj temperaturi (25°C ~ 55°C).
GRIJANJE OFF
Postavka temperature za radnu aktivnost
grijanja OFF (5°C ~ 35°C).
GRIJAČ
Postavka vanjske temperature za radnu
aktivnost grijanja ON (-15°C ~ 20°C).
SPREMNIK
Temperatura sanitarnog spremnika (40
°C ~ 75 °C).
POSTAVKE TERMALNOG POMAKA
TEMPERATURE VODE
1. Pritisnite na 5 sekundi.
Ponovite korake od 3 do 5 da biste postavili željeni
temperaturni pomak (-5°C ~ 5°C).
Napomene:
Pritisnite ili pričekajte 30 sekundi za izlaz iz načina
"SETTING".
Temperatura se pohranjuje u sustavu jednom kada je potvrdite.
Nije moguće aktivirati nin "SETTING" kada su uključeni
pokazatelji "PUMPDW" (Crpka ugašena) i "STATUS" (Status).
Način rada
Temperatura vode
Vanjska temperatura
Parametar *
Prikaz temperature
Pokazatelj SETTING (postavke)
7
HRVATSKI
ENGLISH
7
TIMER
1
MON TUEWEDTHU FRI SAT SUN
2 3 4 5 6
ON
OFF
C
SOLAR REMOTE
Lights up if Timer operation is selected
Day to be selected
ON Timer - To automatically switch “ON” the unit
6 different programs can be set in a day (1 ~ 6)
Indicates the selected day
Water temperature thermo shift (-5ºC ~ 5ºC)
OFF Timer - To automatically switch “OFF” the unit
SET
SELECT
CANCEL
SETTING
CLOCK
OFF/ON
TIMER
STATUS
MODE
HEATER
QUIET
Function Step
Enter timer mode
Press
TIMER
.
Set day & time
1.
Press or to select your desired day.
2.
Press
SELECT
to con rm.
3.
“1” will be blinking, press
SELECT
to set program 1.
4.
Press
OFF/ON
to select ON or OFF timer.
5.
Press or to select your desired time.
You can set
MODE
,
QUIET
,
HEATER
and desired shift temperature with timer.
6.
Press
SET
to con rm program 1. The selected day will be highlighted with .
After 2 seconds, the display will move to the next program.
7.
Repeat steps 4 to 7 to set programs 2 to 6.
• During timer setup, if no button is pressed within 30 seconds, or if the
SET
button is pressed the
setting at that moment is con rmed and timer setup is ended.
Add/Modify timer
Repeat the steps above.
Disable timer
Press
TIMER
, then press
CANCEL
.
Enable timer
Press
TIMER
, then press
SET
.
Check timer
1. Press
TIMER
.
2. Press or until your desired day is shown, press
SELECT
to con rm your selection.
3. Press or to check the set programs.
Cancel timer
1. Press
TIMER
.
2. Press or until your desired day is shown, press
SELECT
to con rm your selection.
3. Press
SELECT
to enter program setting.
4. Press or until your desired program is shown.
5. Press
CANCEL
to cancel the program.
WEEKLY TIMER SETTING
Notes:
You can set the Timer for each day of the week (Monday to Sunday) with 6 programs per day.
When the unit is switched on by the ON TIMER, it will use the previously set temperature to control the water outlet
temperature.
Same timer program cannot be set in the same day.
You may also select collective days with same timer setting.
Promotes energy saving by allowing you to set up to 6 programs in any given day.
F568253_YS0212-1.indb 7 10-Feb-12 3:52:06 PM
Funkcija Korak
Unesite nin broja Pritisnite .
Postavljanje datuma
i vremena
1. Pritisnite ili za odabir željenog datuma.
2. Pritisnite da biste potvrdili.
3. Svijetli "1", pritisnite da biste postavili program 1.
4. Pritisnite da biste odabrali brojač ON ili OFF.
5. Pritisnite ili da biste odabrali željeno vrijeme.
Brojačem možete postaviti , , i željeni pomak temperature .
6. Pritisnite da biste potvrdili program 1. Odabrani dan bit će označen s ▼.
Nakon što prođu dvije sekunde, prikaz će preći na sljedeći program.
7. Ponovite korake od 4 do 7 da biste postavili programe od 2 do 6.
Ako ne pritisnete niti jedan gumb 30 sekundi ili ako pritisnete gumb tijekom podešavanja
brojača, potvrđuje se postavka odabrana u tom trenutku i postavka brojača je završena.
Dodavanje/izmjena
brojača
Ponovite prethodne korake.
Onemogući brojač Pritisnite , a zatim pritisnite .
Omogući brojač Pritisnite , a zatim pritisnite .
Provjera brojača
1. Pritisnite .
2. Pritišćite ili dok se ne prikaže željeni datum, pritisnite da biste potvrdili odabir.
3. Pritisnite ili da biste provjerili postavljene programe.
Poništavanje
brojača
1. Pritisnite .
2. Pritišćite ili dok se ne prikaže željeni dan, pritisnite da biste potvrdili odabir.
3. Pritisnite da biste unijeli programsku postavku
4. Pritišćite ili dok se ne prikaže željeni program.
5. Pritisnite da biste poništili program.
Napomene:
Moguće je podesiti brojač za svaki dan u tjednu (od ponedjeljka do nedjelje] sa 6 programa po danu.
Kada uređaj uključite pomoću gumba BROJAČ ON, koristit će prethodno postavljenu temperaturu za kontroliranje
temperature izlaza za vodu.
Isti program brojača nije moguće postaviti za isti dan.
Možete i odabrati zbroj dana s istom postavkom brojača.
Omogućuje uštedu energije tako što omogućuje postavke do 6 programa u svakom danu.
POSTAVKE TJEDNOG BROJAČA
Pokazuje odabrani dan
Zasvijetli kada odaberete funkciju Timer (brojač)
Za jedan je dan moguće postaviti 6 različitih programa (1 ~ 6)
Termalni pomak temperature vode (-5°C ~ 5°C)
Brojač OFF – Automatsko isključivanje uređaja
Brojač ON – Automatsko uključivanje uređaja
Odabir dana
HEATER
8
8
0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF
/
ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHUFRISAT SUN
SOLAR REMOTE
NOT AVAILABLE
2 3 4 5 6
ON
OFF
INDOOR UNIT
CAUTION
Switch off the power supply before cleaning.
WATER PRESSURE GAUGE
0.2
0.40
0.30.1
MPa
• Do not press or hit the glass
cover with hard, pointed
objects. This may damage the
unit.
• Ensure that the water
pressure is between 0.05 to
0.2 MPa (0.1 MPa = 1 bar).
• In case the water pressure is
out of the above range, please
consult authorized dealer.
CLEANING INSTRUCTIONS HINT
Do not use benzene, thinner or scouring powder.
Use only soap (
pH7) or neutral household detergent.
Do not use water hotter than 40°C.
To ensure optimal performance of the unit, cleaning
maintenance has to be carried out at regular intervals.
Please consult authorized dealer.
INDOOR UNIT & CONTROL PANEL
Do not splash water directly.
Wipe the unit gently with a soft, dry cloth.
EXTERNAL FILTER
Please clean the external lter at least once a year. Fail to do so might cause lter clogged, consequent system
breakdown. Please consult authorized dealer.
OUTDOOR UNIT
Do not obstruct the air inlet and air outlet vents, it may cause low performance or breakdown. Please remove obstacles to
assure the ventilation.
During winter, please clean and remove the snow near outdoor unit so that the snow does not cover the air inlet and air
outlet vents.
INSPECTION
In order to ensure optimal performance of the unit, seasonal inspections on the unit, external lter and eld wiring have to
be carried out at regular intervals. This maintenance should be carried out by authorized dealer.
Clear any obstruction at the air inlet and air outlet vents of outdoor unit.
FOR EXTENDED NON-USE
Turn off the power supply.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:
Abnormal noise during operation.
Water/foreign particles have entered the control panel.
Water leaks from Indoor unit.
Circuit breaker switches off frequently.
Power cord becomes unnaturally warm.
UNUTARNJA JEDINICA
Nemojte prskati vodu direktno na uređaj.
Uređaj nježno obrišite mekom suhom krpom.
Isključite napajanje.
Očistite vanjski ltar barem jednom godišnje. Ako to ne učinite, ltar bi se mogao začepiti, što bi za posljedicu moglo imati
kvar sustava. Posavjetujte se s ovlaštenim dobavljačem.
Nemojte blokirati dovode zraka i izlazne ventile za zrak jer može doći do smanjenih performansi ili kvara. Uklonite
predmete koji blokiraju da biste omogućili ispravnu ventilaciju.
Zimi čistite i uklanjajte snijeg oko vanjske jedinice kako ne bi prekrio dovod zraka i izlazne ventile za zrak.
Da bi se osigurale optimalne performanse uređaja, nužno je provoditi sezonski pregled uređaja, pregled vanjskih ltara i
kabela u redovnim intervalima. Takvo održavanje treba provoditi ovlašteni dobavljač.
Očistite prepreke na otvorima dovoda zraka i ventilima odvoda zraka na vanjskoj jedinici.
U sljedećim slučajevima ISKLJUČITE NAPAJANJE i obratite se ovlaštenom dobavljaču:
Neuobičajena buka tijekom rada.
U upravljačku ploču ušla je voda ili strane čestice.
Iz unutarnje jedinice curi voda.
Strujni se prekidač često isključuje.
Kabel se neobično zagrijava.
UNUTARNJA JEDINICA I UPRAVLJAČKA PLOČA
DULJE RAZDOBLJE NEKORIŠTENJA
VANJSKI FILTAR
VANJSKA JEDINICA
PREGLED
KRITERIJI KOJI SE NE MOGU POPRAVITI
Prije čišćenja isključite napajanje.
MJERAČ ZA PRITISAK VODE
Nemojte pritiskati ili lupati po
staklenom poklopcu tvrdim,
zašiljenim predmetima. Tako
može doći do oštećenja uređaja.
Provjerite je li pritisak vode
između 0,05 i 0,2 MPa (0,1
MPa = 1 bar].
Ako je vodni pritisak iznad gore
navedenog raspona, obratite
se ovlaštenom dobavljaču.
UPUTE ZA ČIŠĆENJE
Ne upotrebljavajte benzen, razrjeđiv ili abrazivna sredstva.
Upotrebljavajte samo sapun (~
_
pH7) ili neutralni
deterdžent za kućanstvo.
Ne upotrebljavajte vodu temperature iznad 40°C.
SAVJET
Da bi se osigurao optimalan rad uređaja, nužno je
čistiti uređaj u pravilnim vremenskim razmacima.
Posavjetujte se s ovlaštenim dobavljačem.
9
HRVATSKI
Sljedeće situacije nisu naznaka kvara.
Gumb forsiranog grijanja
Isključite uređaj i dojavite ovlaštenom dobavljaču kod pogreške.
Rad brojača poništava se kada se pojavi šifra greške.
U SLUČAJU PROBLEMA
SIMPTOM UZROK
Tijekom rada čuje se zvuk protjecanja vode. Protok rashladnog sredstva u uređaju.
Rad počinje nekoliko minuta nakon ponovnog pokretanja
uređaja.
Odgoda znači zaštitu kompresora uređaja.
Iz vanjske jedinice izlaze voda/para. Na cijevima se javlja kondenzacija ili isparavanje.
Vanjska jedinica ispušta paru tijekom grijanja. To je zbog radnji odmrzavanja u izmjenjivaču topline.
Vanjska jedinica ne radi. Kada je vanjska temperatura van operativnog raspona,
sustav toplinske crpke unosi zaštitnu kontrolu.
Gasi se sustav toplinske crpke zrak-voda. Ako je temperatura dovoda za vodu unutarnje
jedinice niža od 20 °C. Uključuje se pomoćni grijač
koji zagrijava vodu.
Sustav se teško zagrijava. Kada se grije unutarnjom jedinicom, a istovremeno
je uključeno i grijanje poda ili panela, moglo bi biti
situacija u kojima je temperatura vode sve niža i
zagrijavanje poda i grijač panela sve slabiji.
Kada je vanjska temperatura zraka niska, možda će
se teže zagrijati.
Blokira li hrpa snijega odvod za ispust ili dovod
vanjske jedinice?
Kada je postavljena temperatura izlaza za vodu
niska, možda će se teže zagrijati.
Sustav se ne može trenutno zagrijati. S obzirom na prirodu sustava toplinske crpke, moglo
bi biti potrebno određeno vrijeme da se voda zagrije
ako se uređaj pokreće na hladno paljenje.
Pomoćni se grijač automatski uključuje kada nije omogućen. Uključivanje pomoćnoga grijača štiti izmjenjivač
topline unutarnje jedinice.
Ponovni početak rada nakon što se struja vrati. Uređaj radi pod funkcijom automatskog ponovnog
pokretanja.
Prije poziva serviseru provjerite sljedeće.
SIMPTOM PROVJERA
Grijanje ne radi učinkovito. Ispravno postavite temperaturu.
Je li ventil za grijanje na panelu zatvoren?
Očistite prepreke na otvorima dovoda zraka i
ventilima odvoda zraka na vanjskoj jedinici.
Bučan rad. Provjerite je li uređaj instaliran na neravnoj površini i
je li poklopac ispravno zatvoren.
Uređaj ne radi. Provjerite je li prekidač oštećen.
LED svjetlo koje označava je li uređaj uključen ne gori ili je
zaslon upravljačke ploče prazan.
Napajanje je isključeno ili je došlo do nestanka struje.
ENGLISH
9
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
SYMPTOM CAUSE
Flowing sound during operation. • Refrigerant ow inside the unit.
Operation is delayed a few minutes after restart. • The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes.
Outdoor unit emits steam during heating mode. • This is due to defrost operation happens at the heat
exchanger.
Outdoor unit does not operate. • When the outdoor temperature is out of the operation
condition range, the heatpump system enter protection
control.
Air-to-Water Heatpump system operation will turn off. • If indoor unit water inlet temperature is lower than 20°C.
Backup heater power will turn on to heat up the water.
System dif cult to heat-up. • When heating is operated by indoor unit together with
oor heating or panel heater simultaneously, there
may be case where warm water temperature is getting
lower and cause oor heating or panel heater heat-up is
weaken.
When outdoor air temperature is low, it may be dif cult to
get warm.
Is the snow pile blocking the discharge outlet or intake
inlet of outdoor unit.
When water outlet set temperature is low, it may be
dif cult to get warm.
System cannot get warm instantly. • Due to the nature of the heatpump system, it may take
some time to heat-up the water if the unit is operated
from cold-start.
Operation starts after power resumes. • Unit is operates under auto restart function.
Check the following before calling for servicing.
SYMPTOM CHECK
Heating operation is not working ef ciently. • Set the temperature correctly.
Is the panel heater valve closed.
Clear any obstruction at the air inlet and air outlet vents
of outdoor unit.
Noisy during operation. • Check if the unit has been installed at an incline or the
cover is not closed properly.
The unit does not work. • Check if the circuit breaker is tripped.
Operation LED is no lit or control panel display
is blank.
• Is the power supply off or power failure.
The operation LED blinks and error code appear on control panel display.
TIMER
TIMER
1
MON TUEWEDTHU FRI SAT SUN
2 3 4 5 6
ON
OFF
Turn the unit off and reveal the error code to authorized dealer.
Timer operation cancel when error code occur.
Force Heater Mode Button
FORCE
In case of a failure of the Air-to-Water Heatpump system, the backup heater can be used to heat
up the heating water. Press
FORCE
to switch on the backup heater.
Press
OFF
/
ON
to stop the force heater operation.
During Force Heater mode, all other operations are not allowed.
LED svjetlo koje označava je li uređaj uključen treperi i šifra greške prikazuje se na zaslonu upravljačke ploče.
U slučaju kvara toplinske crpke zrak-voda moguće je korisititi pomoćni grijač za zagrijavanje
vode. Pritisnite za prebacivanje na pomoćni grijač.
Pritisnite kako biste zaustavili rad forsiranog grijanja.
U načinu forsirano grijanje sve druge radnje nisu dozvoljene.
10
Informacije za korisnike o prikupljanju i zbrinjavanju dotrajale opreme
Ove oznake na proizvodu, ambalaži i/ili pratećim dokumentima označavaju da se korišteni električni i
elektronički uređaji ne smiju zbrinjavati zajedno s otpadom iz domaćinstava.
Radi pravilne obrade, sanacije i recikliranja dotrajalih proizvoda, molimo vas da ih odnesete u odgovarajuća
odlagališta, u skladu s lokalnim zakonodavstvom i Direktivama 2002/96/EZ i 2006/66/EZ. Pravilnim
zbrinjavanjem navedenih proizvoda čuvate vrijedne resurse i sprečavate moguće negativne učinke po
ljudsko zdravlje koji mogu nastati zbog nepravilnog rukovanja otpadom. Detaljne informacije o prikupljanju i
recikliranju dotrajalih proizvoda zatražite od svojeg lokalnog poglavarstva, službe za zbrinjavanje otpada ili
prodavatelja kod kojeg ste kupili proizvode. Nepravilno zbrinjavanje ovog otpada može imati za posljedicu
prekršajnu odgovornost u skladu s nacionalnim zakonodavstvom.
Za poslovne korisnike u Europskoj uniji
Ako želite odložiti električnu i elektroničku opremu, detaljne obavijesti zatražite od svojeg prodavača ili
dobavljača.
[Informacije o odlaganju u zemljama izvan Europske unije]
Ovi su simboli važeći samo u Europskoj uniji. Ako želite odložiti ove uređaje, obratite se nadležnim lokalnim
tijelima ili dobavljačima i raspitajte se o pravilnoj metodi odlaganja.
INFORMACIJE
Information for Users on Collection and Disposal of Old Equipment
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and
electronic products should not be mixed with general household waste.
For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in
accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative
effects on human health and the environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products, please contact your local municipality, your
waste disposal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local
authorities or dealer and ask for the correct method of disposal.
INFORMATION/INFORMATIONS/INFORMACIÓN/
INFORMATIONEN/INFORMAZIONI/ INFORMATIE/
INFORMAÇÃO/ΠΛΗΡΟΦΟΡΙΕΣ/ИНФОРМАЦИЯ
Avis aux utilisateurs concernant la collecte et l’élimination des piles et des appareils usagés
Apposé sur le produit lui-même, sur son emballage, ou gurant dans la documentation qui l’accompagne, ce
pictogramme indique que les piles et appareils électriques et électroniques usagés doivent être séparés des ordures
ménagères.
A n de permettre le traitement, la valorisation et le recyclage adéquats des piles et des appareils usagés, veuillez les
porter à l’un des points de collecte prévus, conformément à la législation nationale en vigueur ainsi qu’aux directives
2002/96/CE et 2006/66/CE.
En éliminant piles et appareils usagés conformément à la réglementation en vigueur, vous contribuez à prévenir
le gaspillage de ressources précieuses ainsi qu’à protéger la santé humaine et l’environnement contre les effets
potentiellement nocifs d’une manipulation inappropriée des déchets.
Pour de plus amples renseignements sur la collecte et le recyclage des piles et appareils usagés, veuillez vous
renseigner auprès de votre mairie, du service municipal d’enlèvement des déchets ou du point de vente où vous avez
acheté les articles concernés.
Le non-respect de la réglementation relative à l’élimination des déchets est passible d’une peine d’amende.
Pour les utilisateurs professionnels au sein de l’Union européenne
Si vous souhaitez vous défaire de pièces d’équipement électrique ou électronique, veuillez vous renseigner directement
auprès de votre détaillant ou de votre fournisseur.
[Information relative à l’élimination des déchets dans les pays extérieurs à l’Union européenne]
Ce pictogramme n’est valide qu’à l’intérieur de l’Union européenne. Pour connaître la procédure applicable dans les pays
hors Union Européenne, veuillez vous renseigner auprès des autorités locales compétentes ou de votre distributeur.
Información para usuarios sobre la recogida y eliminación de aparatos viejos
Estos símbolos en los productos, embalajes y/o documentos adjuntos, signi can que los aparatos eléctricos
y electrónicos y las baterías no deberían ser mezclados con los desechos domésticos.
Para el tratamiento apropiado, la recuperación y el reciclado de aparatos viejos y baterías usadas, por favor,
observe las normas de recogida aplicables, de acuerdo a su legislación nacional y a las Directivas 2002/96/
CE y 2006/66/CE.
Al desechar estos aparatos y baterías correctamente, Usted estará ayudando a preservar recursos valiosos y
a prevenir cualquier potencial efecto negativo sobre la salud de la humanidad y el medio ambiente que, de lo
contrario, podría surgir de un manejo inapropiado de los residuos.
Para mayor información sobre la recolección y el reciclado de aparatos y baterías viejas, por favor, contacte
con su comunidad local, su servicio de eliminación de residuos o al comercio donde adquirió estos aparatos.
Podrán aplicarse penas por la eliminación incorrecta de estos residuos, de acuerdo a la legislación nacional.
Para usuarios empresariales en la Unión Europea
Si usted desea desechar aparatos eléctricos y electrónicos, por favor contacte con su distribuidor o proveedor
a n de obtener mayor información.
[Informacion sobre la Eliminación en otros Países fuera de la Unión Europea]
Estos símbolos sólo son válidos dentro de la Unión Europea. Si desea desechar estos objetos, por favor
contacte con sus autoridades locales o distribuidor y consulte por el método correcto de eliminación.
Ovlašteni predstavnik u EU-u
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Njemačka
F568675
YS0212-0
Panasonic Corporation
Web-mjesto: http://panasonic.hr
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Panasonic WHSHF09D3E8 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI