ASRock Rack E3C236D4M-4L User manual

Category
Servers
Type
User manual
E3C236D4M-4L
User Manual
Version 1.0
Published February 2017
Copyright©2017 ASRock Rack INC. All rights reserved.
Version 1.1
Published May 2017
Copyright©2017 ASRock Rack Inc. All rights reserved.
Copyright Notice:
No part of this documentation may be reproduced, transcribed, transmitted, or
translated in any language, in any form or by any means, except duplication of
documentation by the purchaser for backup purpose, without written consent of
ASRock Rack Inc.
Products and corporate names appearing in this documentation may or may not
be registered trademarks or copyrights of their respective companies, and are used
only for identication or explanation and to the owners’ benet, without intent to
infringe.
Disclaimer:
Specications and information contained in this documentation are furnished
for informational use only and subject to change without notice, and should not
be constructed as a commitment by ASRock Rack. ASRock Rack assumes no
responsibility for any errors or omissions that may appear in this documentation.
With respect to the contents of this documentation, ASRock Rack does not provide
warranty of any kind, either expressed or implied, including but not limited to
the implied warranties or conditions of merchantability or tness for a particular
purpose.
In no event shall ASRock Rack, its directors, ocers, employees, or agents be liable
for any indirect, special, incidental, or consequential damages (including damages
for loss of prots, loss of business, loss of data, interruption of business and the
like), even if ASRock Rack has been advised of the possibility of such damages
arising from any defect or error in the documentation or product.
is device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
CALIFORNIA, USA ONLY
e Lithium battery adopted on this motherboard contains Perchlorate, a toxic substance
controlled in Perchlorate Best Management Practices (BMP) regulations passed by the
California Legislature. When you discard the Lithium battery in California, USA, please
follow the related regulations in advance.
“Perchlorate Material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/
perchlorate
ASRock Racks Website: www.ASRockRack.com
Contact Information
If you need to contact ASRock Rack or want to know more about ASRock Rack,
you’re welcome to visit ASRock Rack’s website at www.ASRockRack.com; or you
may contact your dealer for further information.
ASRock Rack Incorporation
6F., No.37, Sec. 2, Jhongyang S. Rd., Beitou District,
Taipei City 112, Taiwan (R.O.C.)
Contents
Chapter 1 Introduction 1
1.1 Package Contents 1
1.2 Specications 2
1.3 Unique Features 5
1.4 Motherboard Layout 6
1.5 Onboard LED Indicators 9
1.6 I/O Panel 11
1.7 Block Diagram 13
Chapter 2 Installation 14
2.1 Screw Holes 14
2.2 Pre-installation Precautions 14
2.3 Installing the CPU 15
2.4 Installing the CPU Fan and Heatsink 17
2.5 Installation of Memory Modules (DIMM) 18
2.6 Expansion Slots (PCI Express Slots) 20
2.7 Jumper Setup 21
2.8 Onboard Headers and Connectors 24
2.9 Dr. Debug 30
2.10 Unit Identication purpose LED/Switch 31
2.11 Driver Installation Guide 31
2.12 Dual LAN and Teaming Operation Guide 32
Chapter 3 UEFI Setup Utility 33
3.1 Introduction 33
3.1.1 UEFI Menu Bar 33
3.1.2 Navigation Keys 34
3.2 Main Screen 35
3.3 Advanced Screen 36
3.3.1 CPU Conguration 37
3.3.2 Memory Conguration 39
3.3.3 Chipset Conguration 40
3.3.4 Storage Conguration 42
3.3.5 NVMe Conguration 43
3.3.6 ACPI Conguration 44
3.3.7 USB Conguration 45
3.3.8 WHEA Conguration 46
3.3.9 Intel Server Platform Services 47
3.3.10 Super IO Conguration 48
3.3.11 Serial Port Console Redirection 49
3.3.12 H/W Monitor 52
3.3.13 Trusted Computing 53
3.3.14 Intel TXT Information 55
3.3.15 Instant Flash 56
3.4 Boot Screen 57
3.4.1 CSM Parameters 59
3.5 Security 60
3.6 Event Logs 61
3.7 Server Mgmt 63
3.7.1 System Event Log 64
3.7.2 BMC Network Conguration 65
3.8 Exit Screen 67
Chapter 4 Software Support 68
4.1 Install Operating System 68
4.2 Support CD Information 68
4.2.1 Running The Support CD 68
4.2.2 Drivers Menu 68
4.2.3 Utilities Menu 68
4.2.4 Contact Information 68
Chapter 5 Troubleshooting 69
5.1 Troubleshooting Procedures 69
5.2 Technical Support Procedures 70
5.3 Returning Merchandise for Service 70
Chapter 6 Net Framework Installation Guide 71
6.1 Installing .Net Framework 3.5.1 (For Server 2008 R2) 71
E3C236D4M-4L
PB 1
English
Chapter 1 Introduction
ank you for purchasing ASRock Rack E3C236D4M-4L motherboard, a reliable
motherboard produced under ASRock Rack’s consistently stringent quality control.
It delivers excellent performance with robust design conforming to ASRock Racks
commitment to quality and endurance.
In this manual, chapter 1 and 2 contains introduction of the motherboard and step-
by-step guide to the hardware installation. Chapter 3 and 4 contains the conguration
guide to BIOS setup and information of the Support CD.
1.1 Package Contents
• ASRock Rack E3C236D4M-4L Motherboard
(ATX Form Factor: 12-in x 9.6-in, 30.5 cm x 24.4 cm)
• Support CD
• User Manual
• 4 x SATA3 Cables (50cm)
• 2 x SATA3 Cables (60cm)
• 1 x I/O Shield
If any items are missing or appear damaged, contact your authorized dealer.
Because the motherboard specications and the BIOS soware might be updated, the con-
tent of this manual will be subject to change without notice. In case any modications of
this manual occur, the updated version will be available on ASRock Rack website without
further notice. You may nd the latest memory and CPU support lists on ASRock Rack
website as well. ASRock Rack’s Website: www.ASRockRack.com
If you require technical support related to this motherboard, please visit our website for
specic information about the model you are using.
http://www.asrockrack.com/support/
2 3
English
1.2 Specications
E3C236D4M-4L
MB Physical Status
Form Factor ATX
Dimension 12'' x 9.6'' (30.5 cm x 24.4 cm)
Processor System
CPU Intel® Xeon® E3-1200 v5/v6 Series Processors*
*BIOS version 2.0 or above is required for v4 series.
Chipset Intel® C236
System Memory
Capacity 4 x DDR4 DIMM slots
Type - Dual Channel DDR4 memory technology
- Supports DDR4 2400*/2133/1866/1600 ECC/non-ECC**
UDIMM memory
*Only E3-1200 v6 CPUs can support DDR4 2400
**Non-ECC UDIMM support Client OS only.
DIMM Size Per
DIMM
ECC and non-EDD UDIMM : 16GB, 8GB, 4GB
Voltage 1.2V
Expansion Slot
PCIe 3.0 x16 1 slot (PCIE6: x16/x0, x8/x8 )
PCIe 3.0 x4 1 slot (PCIE2 )
Storage
SATA
Controller
C236: 8 x SATA3 6Gb/s (1 port supports SATA DOM),
support RAID 0, 1, 5, 10
Ethernet
Interface 1000 /100 /10 Mbps
LAN 3 x RJ45 GLAN by Intel® i210
1 x RJ45 GLAN by Intel® i219
- Supports Wake-On-LAN
- Supports Energy Ecient Ethernet 802.3az
- Supports Dual LAN with Teaming function
- Supports PXE
- LAN1 supports NCSI
Management
BMC Controller ASPEED AST2400
IPMI Dedicated
GLAN
1 x Realtek RTL8211E for dedicated management GLAN
Features - Watch Dog
- NMI
E3C236D4M-4L
2 3
English
Graphics
Controller ASPEED AST2400
VRAM DDR3 16MB
Rear Panel I/O
VGA Port 1 x D-Sub
USB 3.0 Port 2
LAN Port - RJ45: 4 x GLAN(3 by Intel® i210+ 1 by Intel® i219 )
- LAN Ports with LED (ACT/LINK LED and SPEED LED)
Dedicated LAN RT8211E
Serial Port 1 (COM1)
UID Button/
LED
1
Internal Connector
Auxiliary Panel
Header
1 (includes chassis intrusion, location button & LED, front
LAN LED, event log LED)
SATA DOM 1
TPM Header 1
IPMB Header 1
Buzzer 1
Fan Header 6 (1 CPU / 3 Front / 2 Rear)
ATX Power 1x (24-pin) + 1 x (8-pin)
Type A USB 3.0
Port
1
USB 3.0 Header 1 ( supports 2 USB3.0 ports)
USB 2.0 Header 1 ( supports 2 USB2.0 ports)
System BIOS
BIOS Ty pe 128 Mb AMI UEFI Legal BIOS
BIOS Features - Plug and Play (PnP)
- ACPI 2.0 Compliance Wake Up Events
- SMBIOS 2.8.0 Support
- ASRock Rack Instant Flash
Hardware Monitor
Temperature - CPU Temperature Sensing
- System Temperature Sensing
- System Inlet Temperature Sensing
Fan -CPU/Rear/Front Fan Tachometer
-CPU Quiet Fan (allows Chassis Fan Speed Auto-Adjust by
CPU Temperature)
-CPU/Rear/Front Fan Multi-Speed Control
Voltage Voltage Monitoring: +12V, +5V, +3.3V, CPU Vcore, DRAM,
1.0V_M, +BAT, 3VSB, 5VSB
4 5
English
Support OS
OS Microso® Window
- Server 2008 R2 SP1 (64 bit)
- Server 2012 (64 bit)
- Server 2012 R2 (64 bit)
- Server 2016 (64 bit)
Linux®
- RedHat Enterprise Linux Server 6.6 (32 / 64 bit) / 7.0 (64 bit)
- CentOS 6.6 (32 / 64 bit) / 7.0 (64 bit)
- SUSE Enterprise Linux Server 11 SP3 (32 / 64 bit) /
12.0 (64 bit)
- Fedora core 22 (64 bit)
- Ubuntu 15.04 (64 bit) / 15.10 (64 bit) (AHCI mode)
*Please refer to our website for the latest OS support list.
Note: Server 2008 R2 installation media does not include native driver
support for USB 3.0. Please update a Server 2008 R2 installation image to
include USB 3.0 drivers when installing OS by Server 2008 R2 installation
image. For detailed operation, please reference ASRock Rack’s website:
www.ASRockRack.com.
Environment
Temperature Operation temperature: 10°C ~ 35°C / Non operation
temperature: -40°C ~ 70°C
is motherboard supports Wake from on Board LAN. To use this function, please make
sure that the “Wake on Magic Packet from power o state” is enabled in Device Manager
> Intel® Ethernet Connection > Power Management. And the “PCI Devices Power On” is
enabled in UEFI SETUP UTILITY > Advanced > ACPI Conguration. Aer that, onboard
LAN1&2 can wake up S5 under OS.
If you install Intel® LAN utility or Marvell SATA utility, this motherboard may fail Win-
dows® Hardware Quality Lab (WHQL) certication tests. If you install the drivers only, it
will pass the WHQL tests.
E3C236D4M-4L
4 5
English
1.3 Unique Features
ASRock Rack Instant Flash is a BIOS ash utility embedded in Flash ROM. is con-
venient BIOS update tool allows you to update system BIOS without entering operat-
ing systems rst like MS-DOS or Windows®. With this utility, you can press the <F6>
key during the POST or the <F2> key to enter into the BIOS setup menu to access
ASRock Rack Instant Flash. Just launch this tool and save the new BIOS le to your
USB ash drive, oppy disk or hard drive, then you can update your BIOS only in a
few clicks without preparing an additional oppy diskette or other complicated ash
utility. Please be noted that the USB ash drive or hard drive must use FAT32/16/12
le system.
6 7
English
1.4 Motherboard Layout
DDR3_B1 (64 bit, 240-pin module)
DDR3_A1 (64 bit, 240-pin module)
ATXPWR1
CPU_FAN1
COM1
VGA1
FRNT_FAN1
LAN2
IPMI
LAN
DDR4_B2 (64 bit, 288-pin module)
DDR4_B1 (64 bit, 288-pin module)
DDR3_B1 (64 bit, 240-pin module)
DDR3_A1 (64 bit, 240-pin module)
DDR4_A2 (64 bit, 288-pin module)
DDR4_A1 (64 bit, 288-pin module)
1
PSU_SMB1
ATX12V1
1
1
1
1
1
1
SATA_0
SATA_1
SATA_ 2
SATA_ 3
SATA_ 4
SATA_ 5
SATA_ 6
SATA_ 7
IPMB1
BMC_SMB1
SATAPWR1
REAR_FAN1
LAN1
USB 3.0
T: USB_1
B: USB_2
LAN4
LAN3
1
1
1
1
1
1
FRNT_FAN2
FRNT_FAN3
SATA_PWR1
BAT1
Intel
C236
BUZZER1
Dr.
Debug
PEG_CFG1
1
1
TPM1
PANEL1
1
AUX_PANEL1
HDLED RESET
PLED PWRBTN
1
1
LED_LAN_3_4
USB3_5
USB_1_2
1
1
USB3_3_4
SATA_SGPIO2 SATA_SGPIO1
11
T 1
1
R
11
SEC_OR1
UID1
1
NCSI_SEL1
REAR_FAN2
1
LED_LAN_5_6
123457 8
6910 11 12 13
14
15
16
17
18
19
20
21
22
23
24
25
17.0cm (9.6 in)
E3C236D4M-4L
PCIE6
BIOS
ROM
PCIE2
MEZZ_2
MEZZ_1
NMI_BTN1
PMBUS_SEL_ALT1
PMBUS_SEL_DAT1
PMBUS_SEL_CLK1
CHASSIS_ID1
CHASSIS_ID2
CHASSIS_ID3
ME_RECOVERY1
11
PECI1
30.5cm (12in)
26
27
28
29
30
31
32
333435
36
37
38
39
49
41
42
43
44
45
46
47
48
49
50
BMC
BMC
ROM
Super
I/O
(x16)
(x8)
E3C236D4M-4L
6 7
English
No. Description
1 Chassis ID1 Jumper (CHASSIS_ID1)
2 Chassis ID2 Jumper (CHASSIS_ID2)
3PMBUS Mode Jumper (PMBUS_SEL_CLK1)
4PMBUS Mode Jumper (PMBUS_SEL_DAT1)
5PMBUS Mode Jumper (PMBUS_SEL_ALT1)
6 Chassis ID3 Jumper (CHASSIS_ID3)
7 Non Maskable Interrupt Button (NMI_BTN1)
8 Intelligent Platform Management Bus Header (IPMB1)
9 ATX 12V Power Connector (ATX12V1)
10 BMC SMBus Header (BMC_SMB1)
11 ME Recovery Jumper (ME_RECOVERY1)
12 PSU SMBus (PSU_SMB1)
13 ATX Power Connector (ATXPWR1)
14 2 x 288-pin DDR4 DIMM Slots (DDR4_A2, DDR4_B2, Blue)
15 2 x 288-pin DDR4 DIMM Slots (DDR4_A1, DDR4_B1, White)
16 CPU Fan Connector (CPU_FAN1)
17 Front Fan Connector (FRNT_FAN1)
18 Front Fan Connector (FRNT_FAN2)
19 Front Fan Connector (FRNT_FAN3)
20 CPU PECI Mode Jumper (PECI1)
21 SATA DOM Power Jumper (SATAPWR1)
22 SATA DOM Power Header (SATA_PWR1)
23 SATA3 DOM Connector (SATA_0), Red
24 SATA3 Connector (SATA_1)
25 SATA3 Connector (SATA_2)
26 SATA3 Connector (SATA_3)
27 SATA3 Connector (SATA_5)
28 SATA3 Connector (SATA_4)
29 SATA3 Connector (SATA_7)
30 SATA3 Connector (SATA_6)
31 Flash Descriptor Security Override Jumper (SEC_OR1)
32 System Panel Header (PANEL1)
33 Auxiliary Panel Header (AUX_PANEL1)
8 9
English
No. Description
34 USB 2.0 Header (USB_1_2)
35 Vertical Type A USB 3.0 (USB3_5)
36 Mezzaine Card Slot 2 (MEZZ_2)
37 USB 3.0 Header (USB3_3_4)
38 SATA SGPIO Connector (SATA_SGPIO1)
39 SATA SGPIO Connector (SATA_SGPIO2)
40 PCI Express Graphics Conguration Jumper (PEG_CFG1)
41 ermal Sensor Header (TR1)
42 TPM Header (TPM1)
43 PCIE Card Slot 2 (PCIE2) (x8, from PCH)
44 PCIE Card Slot 6 (PCIE6) (x16, from CPU)
45 Rear Fan Connector (REAR_FAN2)
46 NCSI Mode Jumper (NCSI_SEL1)
47 LAN LED Connector (LED_LAN_3_4)
48 LAN LED Connector (LED_LAN_5_6)
49 Mezzaine Card Slot 1 (MEZZ_1)
50 Rear Fan Connector (REAR_FAN1)
For DIMM installation and conguration instructions, please see p.23 (Installation of Memory Modules (DIMM))
for more details.
E3C236D4M-4L
8 9
English
1.5 Onboard LED Indicators
DDR3_B1 (64 bit, 240-pin module)
DDR3_A1 (64 bit, 240-pin module)
ATXPWR1
CPU_FAN1
COM1
VGA1
FRNT_FAN1
LAN2
IPMI
LAN
DDR4_B2 (64 bit, 288-pin module)
DDR4_B1 (64 bit, 288-pin module)
DDR3_B1 (64 bit, 240-pin module)
DDR3_A1 (64 bit, 240-pin module)
DDR4_A2 (64 bit, 288-pin module)
DDR4_A1 (64 bit, 288-pin module)
1
PSU_SMB1
ATX12V1
1
1
1
1
1
1
SATA_0
SATA_1
SATA_ 2
SATA_ 3
SATA_ 4
SATA_ 5
SATA_ 6
SATA_ 7
IPMB1
BMC_SMB_1
SATAPWR1
REAR_FAN1
LAN1
USB 3.0
T: USB_1
B: USB_2
LAN4
LAN3
1
1
1
1
1
1
FRNT_FAN2
FRNT_FAN3
SATA_PWR1
BAT1
Intel
C236
BUZZER1
Dr.
Debug
PEG_CFG1
1
1
TPM1
PANEL1
1
AUX_PANEL1
HDLED RESET
PLED PWRBTN
1
1
1
LED_LAN_3_4
USB3_5
USB_1_2
1
1
USB3_5_6
SATA_SGPIO2 SATA_SGPIO1
11
T 1
1
R
11
SEC_OR1
UID1
1
NCSI_SEL1
REAR_FAN2
1
LED_LAN_5_6
E3C236D4M-4L
PCIE6
BIOS
ROM
PCIE2
MEZZ_2
MEZZ_1
NMI_BTN1
PMBUS_SEL_ALT1
PMBUS_SEL_DAT1
PMBUS_SEL_CLK1
CHASSIS_ID1
CHASSIS_ID2
CHASSIS_ID3
ME_RECOVERY1
11
PECI1
BMC
1
2
3
4
5
7
6
8
BMC
ROM
Super
I/O
10 11
English
No. Item Status Description
1 SB_PWR1 Green STB PWR ready
2FAN_LED1 Amber CPU_FAN1 failed
3FAN_LED2 Amber Front_FAN1 failed
4FAN_LED3 Amber Front_FAN2 failed
5FAN_LED4 Amber Front_FAN3 failed
6BMC_LED1 Green BMC heartbeat LED
7FAN_LED6 Amber Rear_FAN2 failed
8FAN_LED5 Amber Rear_FAN1 failed
E3C236D4M-4L
10 11
English
1.6 I/O Panel
6
5
3
2
1
4
87 9
No. Description No. Description
1VGA Port (VGA1) 6 LAN RJ-45 Port (LAN2)**
2 Serial Port (COM1) 7 LAN RJ-45 Port (LAN3)**
3 USB 3.0 Ports (USB3_1_2) 8 LAN RJ-45 Port (LAN4)**
4 LAN RJ-45 Port (IPMI_LAN)* 9 UID Switch (UID1)
5 LAN RJ-45 Port (LAN1)**
Note: LAN1 supports NCSI.
LAN Port LED Indications
*ere are two LED next to the LAN port. Please refer to the table below for the LAN port
LED indications.
Dedicated IPMI LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O No Link O 10M bps connection or no
link
Blinking Green Data Activity O 100M bps connection
On Link Yel low 1Gbps connection
ACT/LINK LED
SPEED LED
LAN Port
12 13
English
**ere are two LEDs on each LAN port. Please refer to the table below for the LAN port
LED indications.
LAN Port LED Indications
Speed LED Activity / Link LED
Status Description Status Description
O 10Mbps connection or
no link
O No Link
Yellow 100Mbps connection Blinking Green Data Activity
Green 1Gbps connection On Link
ACT/LINK LED
SPEED LED
LAN Port
E3C236D4M-4L
12 13
English
1.7 Block Diagram
CONTROL
LAN MEZZ PRES ENT
CONTROL
STORAGE MEZZ PRES ENT
LAN MEZZ
Storage
MEZZ
PCIE X16 SLOT6
(X16/X8)
8:15
8:15
PCI-E Ge n3
8:15
X 8
0:7SWITCH1 0:7
0:7
L
L
H
H
X 8
SWITCH2
PCI-E Ge n3
C236
RTL8211E
RGMII
MNG RJ45
DDR4 1866/2133
B1
UART
PCI-E2 x1
LPC
SIO
NCT6791
DDR3
256MB
SPI
uB oot
SPI
SPI FLASH
SYSTEM BIOS
TPM-S
Header
Serial Port
VGA Port
RGMII
RGB
  % 0 &
$6 7  
SPI
USB2
PWM
REAR FAN2
CPU FAN1
FRNT FAN1
FRNT FAN2
FRNT FAN3
REAR FAN1
SATA 3
SATA_1SATA_0 ( SATA DOM )
SATA 3
SATA 2-7
DDR4 1866/2133
B2
DDR4 1866/2133
A2
USB3.0
2 Front ports
SuperSpeed USB
USB3.0
Type A
SuperSpeed USB
USB2.0 High-Speed USB
2 Front ports
480Mb/sUS B2.0
INTEL I210
(LAN1 NCSI)
PCIE x1 100MHz
INTEL I210
(LAN2)
PCIE x1 100MHz
DMI 3.0
INTEL
E3C 236D4M -4L
LGA-1151 Pin Socket
Channel B
INTEL
Processor
128-bit Dual-Channel Memory x 4 Slots
DDR4 1866/2133
A1
Channel A
PCH-H
USB3.0
2 Rear ports
5Gb/s
SuperSpeed USB
US B3.0
5Gb/sUS B3.0
5Gb/sUS B3.0
PCIE x4
INTEL I210
(LAN3)
PCIE x1 100MHz
INTEL I219-LM
(LAN4)
PCIE x1 100MHz
PCIE X4 SLOT2
14 15
English
Chapter 2 Installation
is is an ATX form factor (12'' x 9.6'', 30.5 cm x 24.4 cm) motherboard. Before you install
the motherboard, study the conguration of your chassis to ensure that the motherboard
ts into it.
2.1 Screw Holes
Place screws into the holes indicated by circles to secure the motherboard to the chassis.
Do not over-tighten the screws! Doing so may damage the motherboard.
2.2 Pre-installation Precautions
Take note of the following precautions before you install motherboard components or
change any motherboard settings.
1. Unplug the power cord from the wall socket before touching any components.
2. To avoid damaging the motherboards components due to static electricity, NEVER
place your motherboard directly on the carpet or the like. Also remember to use a
grounded wrist strap or touch a safety grounded object before you handle the compo-
nents.
3. Hold components by the edges and do not touch the ICs.
4. Whenever you uninstall any component, place it on a grounded anti-static pad or in
the bag that comes with the component.
5. When placing screws into the screw holes to secure the motherboard to the chassis,
please do not over-tighten the screws! Doing so may damage the motherboard.
Before you install or remove any component, ensure that the power is switched o or the
power cord is detached from the power supply. Failure to do so may cause severe damage to
the motherboard, peripherals, and/or components.
Make sure to unplug the power cord before installing or removing the motherboard. Failure
to do so may cause physical injuries to you and damages to motherboard components.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79

ASRock Rack E3C236D4M-4L User manual

Category
Servers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI