WURM MULTIGATE 3 Product information

Type
Product information
Multi-communication gateway with 2 C-BUS interfaces
MULTIGATE_3-SL_V1.1.2_PI_2023-01_EN 1
Subject to technical changes
MULTIGATE 3
1 MULTIGATE 3
Multi-communication gateway with 2 C-BUS interfaces
1.1 Front view
Fig. 1: Front view
Data interface to plants with Wurm control
Connection via LAN
Simultaneous access of several users via several routes
Comfortable visualisation and control with FRIGODATA XP
Supports the CAN-AP for access with Frida App via Bluetooth® Low Energy
Manager for SAC (Security Access Control)
2 separate Wurm CAN communication buses (C-BUS) each with 120 addresses and 3 trades
Higher baud rates can be set separately for each C-BUS
Direct connection of a PC with FRIGODATA XP
Various alarm destinations and fault reporting routes for each section
Trade-differentiated access management
Plot data and DOKUPLOT data stored for up to 2 years
Processing of weather forecast data with the MLB management module (optional)
Saves temperature data according to HACCP standard with W-LINKpro and W-LINKpro-B
(optional)
Connection to the Wurm system via C-BUS and FRIGODATA XP
1.2 Scope of supply
MULTIGATE 3 device
Product information
2 x PE top-hat rail terminals
3 x short PE connection wires (green / yellow)
Numbered, plug-in screw terminals
Multi-communication gateway with 2 C-BUS interfaces
2 MULTIGATE_3-SL_V1.1.2_PI_2023-01_EN
Subject to technical changes
MULTIGATE 3
1.3 Safety instructions
Writing conventions
WARNING Avoid the described hazard: Otherwise there is danger from electric voltage that can lead to
death or serious bodily injury.
CAUTION Avoid the described hazard: Otherwise minor or medium bodily injury or property damage will
result.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the prod-
uct and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold. Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in the case
of improper use or use for purposes other than the intended purpose.
WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant when carrying out installation, wiring or disassembly work!
Otherwise, mains voltage and/or external voltage may still be present, even if the control voltage
is switched off!
The wiring of the device must be carried out only by qualified electricians!
Use the correct tools for any work!
Check the entire wiring after connection!
Observe the maximum loads for all connections!
Never expose the device to moisture, for example due to condensation or cleaning agents.
Stop operating the device if it is faulty or damaged and its safe operation is compromised!
Do not open the device.
Do not repair the device yourself! If the device requires repairs, send it in with an exact descrip-
tion of the fault!
Version and validity of the documentation
Any versions not listed are special solutions for individual projects and are not described in detail in this document.
This document will automatically cease to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
You can find more information on our website at www.wurm.de.
Target group This manual is intended for "service technician" personnel.
Intended use
MULTIGATE 3 provides remote data transmission. Amongst other
things, it automatically forwards alarms to up to 5 destinations per sec-
tion.
Version Date
V1.1.2 and higher 2022-05 Documentation status
Multi-communication gateway with 2 C-BUS interfaces
MULTIGATE_3-SL_V1.1.2_PI_2023-01_EN 3
Subject to technical changes
MULTIGATE 3
1.4 Connection diagram
Fig. 2: Connection diagram
         
   
         

         
    
         


 

&%86 
&%86 
/$1 
56
$ODUP
$6&,,6HUYHU
0RGEXV7&3
0(7(2/,1.
3RZHU
'2  $ODUP 
'2  $ODUP
'2  $ODUP
'2
'D\WLPH RSHUDWLRQ
6HUYLFH
08/7,*$7(
&
$8;
86%'HYLFH 86%+RVW &%86
9
/
6
+
$
%
9
75 6
56
1
/
'RQRWFRQQHFW
75 6\P
'2 $ODUP
$
',
6HUYLFH
%DXG
7[
5[
7[
5[
)DXOW
21
21 7[
5[
7[
5[
/
1
/
1
','D\
9a
'2 $ODUP
9a$
'2
9a$
3RZHU '2 $ODUP
9a$ ,QLW 6HUYLFH /$1 &%86
%DXG
9
/
6
+
75 6
9a
+]9$
21
21
7[
5[
/LQN$FW
21
7[
5[
21
21
21
21
21
21
21
Multi-communication gateway with 2 C-BUS interfaces
4 MULTIGATE_3-SL_V1.1.2_PI_2023-01_EN
Subject to technical changes
MULTIGATE 3
1.5 Installing the device
The device is intended for top-hat rail installation and is suitable for operation in fuse boxes and dis-
tribution cabinets. The device can be positioned immediately adjacent to another device without gaps.
WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant before installing. Otherwise, mains voltage and/or exter-
nal voltage may still be present, even if the control voltage is switched off!
Observe the maximum loads for all connections!
The entire plant must be free of voltage.
1. (A) Place the device with the leading edge at an acute angle to the top-hat rail.
2. (B) Push the device downwards onto the top-hat rail.
The device snaps into place with the fastening safety catch (a) on the top-hat rail.
You can now connect the device.
Fig. 3: Top-hat rail installation
1.6 Technical data
Power supply 230V~, +10% / -15%, 50Hz, 16VA
Inputs 1 x 230V~, day operation input (light contact)
1 x 230V~, service or universal input DI 2
Universal outputs 2 x change-over contacts: 230V~, 4(2)A (DO 1, DO 2), collective alarm
or universal output
(Attention! Not for safety extra-low voltage!)
1 x change-over contact: 4(2)A (DO 3), collective alarm or universal
output
1 x normally open contact: 230V~, 4(2)A (DO 4), external router reset
or universal output
(Attention! Not for safety extra-low voltage!)
Communication Ethernet interface LAN 1 for network connection 10Base-T/100Base-
TX with RJ45 socket (remote data transmission)
2 x 3-conductor CAN bus interface, shielded, galvanically isolated, 4
switchable baud rates, 2 x RJ45 and screw terminals 2.5mm² each,
switchable termination
3-conductor RS485 interface prepared, currently without function, gal-
vanically isolated, separately switchable termination and balancing
USB host interface (type A) for firmware update
USB device interface (type B) for FRIGODATA XP
Connection options 16 x universal FIO-type input and output modules for detecting digital
signals (via C-BUS 1 or C-BUS 2)
Display 15 x LED (3-coloured)
Keys Init (reinitialisation of C-BUS 1 and C-BUS 2)
Service (temporary alarm suppression)
Aux (additional functions)
Housing • Plastic
• IP20
Dimensions (W x H x D) 213 x 92 x 62mm (DIN 43880)
Ambient temperature Operation: 0...+55°C, storage: -25…+70°C
Weight About 455g
CE conformity - 2014/30/EU (EMC Directive)
- 2014/35/EU (Low Voltage Directive)
RoHS II
Valid from Version 1.1.2
A
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

WURM MULTIGATE 3 Product information

Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI