  • Hello! I've reviewed the installation instructions for the AGI conveyor lighting kit. This document covers installation for 1545FL FMD, 1545 FLUM, and 2045FL FMD models. The kit includes a flood lamp, two mini-flood lamps, and associated hardware. The document details mounting and wiring procedures. I'm ready to answer your questions about setting up this lighting kit.
  • What does the lighting kit include?
    Which conveyor models are these instructions applicable to?
    What should be done before attempting to install this product?
    What is the first step in the installation process?
    Where are the lamps mounted?
PART NUMBER: P1512004 R2
REVISED: 6/4/18
Read and understand the safety information in the appropriate conveyor assembly
manual before proceeding.
Read and understand the instructions in this manual before attempting to install this
product.
The lighting kit consists of one flood lamp, two mini-flood lamps, a mounting bracket,
hardware, wiring P-clamps, and a wiring harness with a fused light switch box.
1. Route the wiring harness along the tube through the weather guard mount
brackets (see Figure 1.2).
2. Install the lamps:
Fasten the discharge-area mini-flood lamp to the existing hole in the side of
the spout.
Fasten the mid-conveyor flood lamp to the center hole of the fitted weather
guard mount bar (if a center hole is not present, drill a 1/4" hole in the center of
the weather guard mount bar).
Secure the bracket for the intake-area mini-flood lamp to the tube flange using
existing fasteners. Fasten the lamp to the bracket.
Plug the wiring harness connectors into the lamp connectors. Ensure that the
connectors are fully engaged. Fasten the wiring harness with P-clamps near
each lamp.
3. Install the switch box on the control box with the two screws supplied.
4. Connect the wiring-harness eyelet (black wire) to the control box (ground).
Connect the piggy back blade connector (white wire) to the ignition power in the
control box (positive). See Figure 1.1.
Figure 1.1 Control Box Connections
These instructions apply to the following Batco FX and Westfield WCX models:
1545FL FMD, 1545 FLUM
2045FL FMD
CONVEYOR LIGHTING KIT
INSTALLATION INSTRUCTIONS
WHITE WIRE
BLACK WIRE
2
Figure 1.2 Conveyor Lighting Kit
SWITCH BOX
DISCHARGE AREA
(MINI-FLOOD LAMP)
MID-CONVEYOR
(FLOOD LAMP)
INTAKE AREA
(MINI-FLOOD LAMP)
/