www.usaprocom.com
160177-01B2
2. Fueling
a) Personnel involved with fueling shall be
qualied and thoroughly familiar with
the manufacturer's instructions and
applicable regulations regarding the
safe fueling of heating units.
b) Only the type of fuel specied on the
heater's data plate shall be used.
c) All ame shall be extinguished and the
heater allowed to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-
line connections shall be inspected for
leaks. Any leaks shall be repaired prior
to returning the heater to service.
e) At no time shall more than one day's
supply of heater fuel be stored inside
a building in the vicinity of the heater.
Bulk fuel storage shall be outside the
structure.
f) All fuel storage shall be located a mini-
mum of 25 feet (762 cm) from heaters,
torches, welding equipment and similar
sources of ignition (exception: fuel res-
ervoir integral with heater unit or any
authorized auxiliary tank connected to
heater unit).
g) Whenever possible, fuel storage shall
be conned to areas where oor pen-
etrations do not permit fuel to drip onto
or be ignited by a re at lower elevation.
h) Fuel storage shall be in accordance
with the authority having jurisdiction.
3. Use only the electrical voltage and fre-
quency specied on model plate.
4. Heater is suitable for outdoor use.
5. Heater must be grounded. Use only a
properly grounded three-wire extension
cord. Plug into grounded outlet only.
6. Use only in areas free of ammable va-
pors or high dust content.
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birth defects or other reproduc-
tive harm.
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble,
operate or service this heater.
Improper use of this heater can
cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the u,
with headaches, dizziness and/or nausea. If
you have these signs, the heater may not be
working properly. Get fresh air at once! Have
heater serviced. Some people are more af-
fected by carbon monoxide than others. These
include pregnant women, persons with heart
or lung disease or anemia, those under the
inuence of alcohol and those at high altitudes.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.
1. Use only kerosene, #1/#2 diesel/fuel oil,
JET A or JP-8 fuels to avoid risk of re or
explosion. Never use gasoline, oil from
crank cases, naphtha, paint thinners,
alcohol or other highly ammable fuels.
SAFETY
TABLE OF CONTENTS
Safety ........................................................ 2
Unpacking.................................................. 3
Assembly ................................................... 3
Product Identication and Label Locations ... 4
Specications ............................................ 5
Fuels .......................................................... 5
Ventilation .................................................. 5
Operation ................................................... 6
Operation with Portable Generator ............ 7
Storing, Transporting or Shipping .............. 7
Preventative Maintenance Schedule ......... 7
Troubleshooting ......................................... 8
Service Procedures ................................... 9
Wiring Diagram ........................................ 15
Technical Service..................................... 15
Accessories ............................................. 15
Parts ........................................................ 16
Replacement Parts .................................. 19
Warranty .................................................. 20