①DC Auto Iris Lens
②Infrared LED
③Focal & Zoom Adjustment Lever
④Gimbal Bracket
Total Pixels 811(H) x 508(V) 795(H) x 596(V)
Effective Pixels 768(H) x 494(V) 752(H) x 582(V)
Sensor 1/3" High Resolution CCD
Scanning System 2:1 Interlace
Horizontal :15.734KHzVertical : 59.94Hz
Horizontal :15.625KHzVertical : 50.00Hz
Resolution More than 630 TV Lines
Video Output 1.0Vp-p Composite Signal ( 75ohm )
Electronic shutter speed 1/60s - 1/100,000s 1/50s - 1/100,000s
3D-DNR OFF / ON Selectable(LOW / MIDDLE / HIGH / CNR)
Sens-Up OFF / AUTO( x2 ~ x1024)
D&N Selection AUTO / COLOR / BW / EXT
D-WDR ON / OFF Selectable
IR SMART ON / OFF Selectable
Motion Detection OFF / ON(AREA 1~4)
Privacy Masking OFF / ON(MASK 1~8)
MIRROR ON / OFF Selectable
SHARPNESS ON / OFF (Level Adjustable 1~50)
Lens Mount 2.8~12mm DC Auto Iris
Operating temperature/Humidity -10℃~+50℃ / 0~80% RH
Power Supply DC12V 110mA (CDS ON : 350mA Max)
Dimensions 112(W)mm X 87(D)mm
Defect Pixel Compensation
OFF / LOW / MIDDLE / HIGH
0 Lux for Infrared Lighting Conditions
ATW / AWC / MANUAL / PUSH
SPECIFICATIONS
SETTING & INSTALLATION
When you install the camera,
please glue up the end of
cable to keep it stable in order
to protect the camera from
the humidity problems.
!
Adjustable Angle
(Tilt : 10~90˚ / Manual)
Adjustable Angle
(Pan : 0~355˚ / Manual)
1. Dome Base Mounting
- Open the dome cover.
- Mount the base of camera to a sturdy surface using screws with
accessories supplied through premade holes on the base
of the dome.
2. Power Connection & Monitor Impedance
- To avoid fire or shock hazard, always use a CE listed power supply.
- Check Monitor impedance switch if the image is blurred.
3. Camera Adjustment
- Adjust camera angel by moving the gymbal bracket.
- Adjust Zoom and Focus by lever attached to lens if it is varifocal lens.
- Use the OSD control to select the different camera functions if it is
OSD model.
4. Dome Cover Mounting
- Put the dome cover back and make sure it is properly fixed. Z