Cumberland Snubber Product information

  • Hello! I have analyzed the provided document, which contains wiring diagrams and instructions for installing snubbers with 240 VAC actuators, including individual snubbers and snubber kits. The document emphasizes safe installation practices and proper placement of junction boxes and plastic boxes. I am ready to answer your questions about the products described in this document.
  • What voltage are the actuators designed for?
    What is the purpose of the snubber?
    Where should the junction box be placed?
    What is the purpose of the plastic box from kit?
Date: 10-08-21 V1.0 PNEG-2362
Instructions
1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421
PNEG-2362
Page 1 of 2
Printed in the USA
Copyright © 2021 by The GSI Group, LLC
www.automatedproduction.com /
www.cumberlandpoultry.com
CN-365337
Snubber Wiring Diagrams
Snubber Wiring Diagram for 240 VAC Actuator
Figure 1 Snubber Wiring Diagram for 240 VAC Actuator
240 VAC actuators needs to be
equipped with snubbers.
240 VAC Actuator
* Junction box should be placed as close
as possible to the actuator/inlet.
From electrical
distribution
panel
OPEN Red
White
Green/Yellow
Green/Yellow
L2/N
L1 Black
Black
Black
Black
SNUBBER
(See note)*
SNUBBER
(See note)*
Red
Junction Box
NC
RELAY
SNUBBER PART NUMBER:
US: E305-0548
CANADA: 121-00021
RELAY
NC
NO
NO
COM
COM
Blue Blue
White
CLOSE
COM
Disconnect and lock out all power sources before installing wires/cables or servicing equipment.
Page 2 of 2 PNEG-2362
Snubber Wiring Diagrams
Snubbers Kit Wiring Diagram for 240 VAC Actuator
Figure 2 Snubbers Kit Wiring Diagram for 240 VAC Actuator
240 VAC actuators needs to be
equipped with snubbers.
240 VAC Actuator
* Plastic box from kit should be placed as
close as possible to the actuator/inlet.
From electrical
distribution
panel
OPEN Red
White
White
Green/Yellow
L2/N
L1 Black
Black
Black
Black
Black
Plastic Box from Kit
NC
RELAY
SNUBBER KIT (with plastic box):
US: EDGE-204
RELAY
NC
NO
NO
COM
COM
Blue
Red
Blue
CLOSE
COM
OPEN
CLOSE
COM
SNUBBER
(See note)*
SNUBBER
(See note)*
Disconnect and lock out all power sources before installing wires/cables or servicing equipment.
/