Date: 10-08-21 V1.0 PNEG-2362
Instructions
1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421
Page 1 of 2
Printed in the USA
Copyright © 2021 by The GSI Group, LLC
www.automatedproduction.com /
www.cumberlandpoultry.com
CN-365337
Snubber Wiring Diagrams
Snubber Wiring Diagram for 240 VAC Actuator
Figure 1 Snubber Wiring Diagram for 240 VAC Actuator
240 VAC actuators needs to be
equipped with snubbers.
240 VAC Actuator
* Junction box should be placed as close
as possible to the actuator/inlet.
From electrical
distribution
panel
OPEN Red
White
Green/Yellow
Green/Yellow
L2/N
L1 Black
Black
Black
Black
SNUBBER
(See note)*
SNUBBER
(See note)*
Red
Junction Box
NC
RELAY
SNUBBER PART NUMBER:
US: E305-0548
CANADA: 121-00021
RELAY
NC
NO
NO
COM
COM
Blue Blue
White
CLOSE
COM
Disconnect and lock out all power sources before installing wires/cables or servicing equipment.