Marantec EM 184 Owner's manual

Type
Owner's manual
Expansion module EM 184
Draw-in protection MSBUS
XW41C
XW41A
LED 4
LED 3
LED 2
LED 1
24V DOWN
E F
DIP
12V UP
ES MODUL
XP16A XP16B
GN GN
BN BN
WH WH
Manual for installation and operation
GB
2 Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543)
2. Table of contents
Caution!
Danger of personal injury!
The following safety advice must be
observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must be
observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
1. Meaning of symbols . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . .2
3. General safety advice . . . . . . . . .3
4. Product overview . . . . . . . . . . . .5
5. Installation . . . . . . . . . . . . . . . . .5
5.1 Install expansion module . . . . .5
5.2 Wiring of the expansion
module . . . . . . . . . . . . . . . . . .6
6. Initial operation . . . . . . . . . . . .10
7. Appendix . . . . . . . . . . . . . . . . . .11
1. Meaning of symbols
Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543) 3
3. General safety advice
Target group
This operator system may only be installed, connected and put into operation by qualified and trained
professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed.
Disregarding these warnings may lead to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
To avoid installation errors and damage to the device, it is imperative that the installation instructions are
followed. The product may only be operated after reading these installation and operating instructions.
The installation and operating instructions are to be given to the door system user, who must keep them
safe. They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's
Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition with
regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented)
before they are put into operation and thereafter as required, but at least once a year.
Correct use
The extension module expands a control unit with MSBUS.
Beside the advice in these instructions, please observe the general safety and accident
prevention regulations! Our sales and supply terms and conditions are effective.
Please read carefully!
3. General safety advice
Installation tips
• Ensure that the devices to be connected (doors etc.) are in a mechanically faultless state.
• Before commencing cabling works it is very important to disconnect the system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately.
The operating voltage is 24 V.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully!
4 Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543)
Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543) 5
XW41A
LED 4
LED 3
LED 2
LED 1
ES MODUL
XW41C
XP16A XP16B
GN GN
BN BN
WH WH
24V DOWN
E F DIP
12V UP
Supply package
Dimensions
1 Expansion module
2 MSBUS cable
3 System cable coded
4 Manual for installation and operation
1
4 / 1
3
2
XW41A
LED 4
LED 3
LED 2
LED 1
ES MODUL
XW41C
XP16A XP16B
GN GN
BN BN
WH WH
24V DOWN
E F DIP
12V UP
4 / 2
126
48
44
5.1 Install expansion module
5. Installation
• Fit the expansion module (B) to the DIN rail (A).
4. Product overview
4
XW41C
XW41A
LED 4
LED 3
LED 2
LED 1
24V DOWN
E F DIP
12V UP
ES MODUL
XP16A XP16B
GN GN
BN BN
WH WH
5.1 / 1
A
B
XW41B
XW41C
XW41A
LED 4
LED 3
LED 2
LED 1
XP16A XP16B
GNGN
BN BN
WHWH
24V DOWN
EF DIP
12V UP
ON
OFF
5. Installation
6 Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543)
Label Type / function
A
Operating indicator
Light on .......... In operation
B Draw-in protection XP16A
C Draw-in protection testing
D Draw-in protection XP16B
E Dip switch DIP E
F Dip switch DIP F
XP16A Draw-in protection 1
XP16B Draw-in protection 2
XW41A MSBUS connection
XW41B MSBUS connection
XW41C MSBUS connection
5.2 Wiring of the expansion
module
5.2.1 Overview of the module connections
B, C, D:
Light flashes
.......... Cable break
Single flash (run light)
...scanning MSBUS
5.2.1 / 1
D
A
B
XW41A
E
F
XP16B
XP16A
XW41CXW41B
C
Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543) 7
5. Installation
Attention!
To ensure correct operation, only the
MSBUS system must be used.
5.2.2 Connection of the modules
• Connect the MS bus control unit to the
connecting socket XW41A or XW41B.
• Connect further modules to socket XW41C as
required.
Connection of the control unit and a further
module
DIP E Function
OFF
Draw-in protection 12V
(factory setting)
ON Draw-in protection 24V
DIP F Function
OFF
Both draw-in protection devices
work in the OPENING direction
ON
Both draw-in protection devices
work in the CLOSING direction
DIP switch (E) settings
DIP switch (F) settings
XW41B
XW41C
L
L
L
L
DOWN
E
ON
OFF
XW41B
XW41C
5.2.2 / 1
XW41A
8 Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543)
5. Installation
Anschluss Einzugssicherung dynamisch
5.2.2 / 3
M14E006
Label Type / function
BP29A Draw-in protection, receiver RX
BP29B Draw-in protection, transmitter TX
DIP E Function
OFF Draw-in protection 12V
DIP switch (E) settings
Connection for draw-in protection tested
Label Type / function
BP30A Draw-in protection, receiver RX
BP30B Draw-in protection, transmitter TX
X1 Terminal
5.2.2 / 2
M14E006
DIP E Function
OFF Draw-in protection 12V
ON Draw-in protection 24V
DIP switch (E) settings
Attention!
Selecting the wrong voltage will
destroy the photocell.
Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543) 9
Connection for draw-in protection with relay
5.2.2 / 4
M14E006
Label Type / function
BP31A Draw-in protection, receiver RX
BP31B Draw-in protection, transmitter TX
DIP E Function
ON Draw-in protection 24V
DIP switch (E) settings
5. Installation
Assignment of terminals
I –> Test signal for draw-in protection
GN Signal of draw-in protection
BN
+ 24V / +12V DC,
depending on DIP switch E
WH GND
Key to cable colours
BN brown
GN green
WH white
YE yellow
10 Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543)
After connecting the control unit, the LED
displays (B, C, D) flashes slowly (Module not
connected to MSBUS).
• The module will be recognised automatically by
the control during initial use.
The control unit requires approx. 30 seconds to
recognise any modules connected to it.
The module reset ends automatically
(run light display B, C, D – MSBUS module
recognised).
A Operating indicator
B Draw-in protection photocell (EZS) 1
connected
C Draw-in protection testing (EZS)
D Draw-in protection photocell (EZS) 2
connected
6. Initial operation
Advice:
The draw-in protection must be
connected up before initial use.
Possible draw-in protection:
- Three-wire draw-in protection,
- Four-wire draw-in protection with
testing, or
- Draw-in protection with relay
XW41B
XW41C
XW41A
LED 4
LED 3
LED 2
LED 1
XP16A XP16B
GN GN
BN BN
WH WH
24V DOWN
EF DIP
12V UP
6 / 1
B
A
C
D
Manual for installation and operation, Expansion module EM 184 GB (#116357 / 1700020543) 11
7. Appendix
Technical data
Operating
voltage
V 24 to 30
Max. draw-in
protection
current
mA 200
Protection
category
IP 20
Cabling
Conventional /
MSBUS cable
Dimensions
(WxHxD)
mm 126 x 48 x 46
Internal
consumption
mA 60
Weight kg 0.15
English Original instructions, Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements.
Valid from: 07.2015
#116357 / 1700020543
1 - GB/KD 360414 - M - 0.5 - 0414
116357
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Marantec EM 184 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document