BEFOREYOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT- Save these instructions for
local inspector's use.
IMPORTANT- Observe all governing codes
and ordinances.
Noteto Installer - Besureto leavethese
instructionswith thecustomer.
Note to Customer - Keep these instructions
with gour Use and Care Book for future
reference.
Before the old drger is removed from service or
discarded, remove the drger door.
Inspect the drger exhaust outlet and straighten
the outlet walls if theg are bent.
Service information and the wiring diagram
are located in the control console.
Do notallow children on or inthe appliance.
Close supervisionof children is necessarg when
the applianceis used near children.
Install the drgerwhere the temperatureis
aboveSO°Ffor satisfactorg operationof the
drger controlsgstem.
WARNING RBKOFFIRE
Toreducethe riskof severeinjurgor death,followall installation instructions.
Clothesdrger installationmustbeperformedbg aqualified installer.
Installthe clothesdrger accordingtotheseinstructionsand in accordancewith local
codes.Inthe absenceof localcodes,installationmust comptgwith NationalFuelGas
Code,ANSIZ225.1/NFPA54or the CanadianNaturalGasand PropaneInstallationCode,
CSAB149.1.
ColifomioSafeDrinkingWaterond ToxicEnforcementAct.
Thisact requiresthe governorof Californiato publisha listof substancesknownto the
stateto causecancer,birth defectsor otherreproductiveharm andrequiresbusinesses
to warn customersof potential exposureto suchsubstances.Gasappliancescan
causeminorexposuretofour of thesesubstances,namelg benzene,carbonmonoxide,
formaldehgdeand soot,causedprimaritgbgthe incompletecombustion of naturalgas
or LPfuels.Properlgadjusted drgerswiltminimizeincompletecombustion.Exposure
to thesesubstancescan be minimizedfurther bg properlgventingthe drger to the
outdoors.
Thisdrger must beexhaustedto the outdoors.
Useonlg4" rigid metalducting forexhaustingthe clothesdrger to the outdoors.
DONOTinstall aclothesdrger with flexibleplasticducting materials.Ifflexible metal
(semi-rigidor foit-tgpe)duct isinstalled,it mustbe ULlistedand installedinaccordance
with the instructionsfound in "ConnectingTheDrgerToHouseVent"on page6ofthis
manual.Flexibleventing materialsare knownto collapse,beeasilgcrushed,andtrap
lint.Theseconditionswiltobstructdrger airflow andincreasethe riskoffire.
Donot installor storethisappliance in anglocationwhereit couldbeexposedto water
andor weather.
Drgersinstalledin residentialgaragesmustbeelevated 18"(46cm)abovethe floor.
Savetheseinstructions.(Installers:Besureto leavetheseinstructionswith the
customer).
in the state of Massachusetts,installation must be performed bya qualifiedor
licensedcontractor, plumber, or gasfitter qualified or licensedby the state.
TOOLSYOU
WILLNEED
(x2)
IO"ADJUSTABLEWRENCHES _.
8"PIPEWRENCH LEVEL
SLIPJOINTPLIERS FLATBLADESCREWDRIVER
MATERIALSYOUWILLNEED
4"DIA.METALDUCT I====_
(RECOMMENDED)
4"DIAMMETALELBOW
4"DIA.FLEXIBLEMETAL(SEMI-RIGID)
ULLISTEDTRANSITIONDUCT
(IFNEEDED)
KITWXO8X10077(INCLUDES2ELBOWS) 4"DUCTCLAMPS
4"SPRINGCLAMPS
4"DIA.FLEXIBLEMETAL(FOILTYPE) _(x2)
ULLISTEDTRANSITIONDUCT
(IFNEEDED.)
PIPE
EXHAUSTHOOD COMPOUND
DUCTTAPE
FLEXIBLEGASLINECONNECTOR
SOAPSOLUTION
FORLEAKDETECTION
SAFETYGLASSES
GLOVES
Step 1
Step 2
Step 3
Verifg Your Gas Installation (seesection 2).
Prepare the Area and Exhaust for Installation of
New Drger (seesection 1).
Check and Insure the Existing External Exhaust
is Clean (seesection 1)and Meets Attached
Installation Specifications (seesection 6).
Step 4 Remove the Foam Shipping Pads(seesection 1).
Step 5 Move the Drger to the Desired Location.
Step 6 LevelYour Drger (seesection 8).
Step 7 Connect the Gas Supplg (seesection 3) and check
for leaks (seesection 4).
Step 8 Connect the External Exhaust (seesection 7).
Step 9 Connect the Power Supplg (seesection 5).
Step 10 Check the Operation of the Power Supplg, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where Theg Will Be
Noticed Bg the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
234Dll13PO02 31-16225-1 07/08/10 GE
Installation instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
m PREPARING FOR INSTALLATION
OF NEW DRYER
TIP:Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
DISCONNECTING GAS
TURNGAS
SHUT-0FFVALVE IC?_ DISCONNECTANDDISCARDOLD f}_!/__
j -,_ FLEXIBLEGASCONNECTORAND
TOTHEOFF
POSITION.,,,_ OLDTRANSITIONDUCTING
MATERIAL.REPLACEWITHNEW
CSA(AGA)APPROVEDFLEXIBLE
GASLINECONNECTORANDUL
APPROVEDTRANSITIONDUCT.
WARNING - NEVERREUSEOLD
FLE×IBLE CON NECTORS.
The use of old flexible connectors can cause leaks and
personal iniury. Always use new flexible connectors
when installing gas appliances.
REMOVING LINT FROM WALL
EXHAUST OPENING
, Remove and discard existing plastic or metal foil
transition duct and replace with ULlisted transition
duct.
WALL
INTERNALDUCT
CHECKTHATEXHAUST
OPENING OPENS
ANDCLOSESFREELY.
TILTTHE DRYERSIDEWAYS
AND REMOVETHE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS, BESURE TO
REMOVE ALL OF THE
FOAM PIECESAROUND
THE LEGS.
[] GAS REQUIREMENTS
WARNING
Installation must conform to local codes and
ordinances, or in their absence, the NATIONAL FUEL
GASCODE,ANSI Z223.
This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using
conversion kit WE25×0217, your local service
organization can convert this dryer for use with
propane {LP)gas. ALL CONVERSIONSlUST BEMADE BY
PROPERLYTRAINEDAND QUALIFIEDPERSONNELAND
IN ACCORDANCEWITH LOCALCODESAND ORDINANCE
REQUIREMENTS.
The dryer must be disconnected from the gas supply
piping system during any pressure testing of that
system at a test pressure in excess of O.5PSI{3.4 KPa).
The dryer must be isolated from the gas supply piping
system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping of test
pressure equal to or less than 0.5 PSI(3.4 KPa).
DRYER GAS SUPPLY CONNECTION
xc:_ z:E_ j
' 318"NPTHALETHREADGASSUPPLY
NOTE:Addtoverticoldimension
thedistancebetweencobinet
bottomtofloor.
GAS SUPPLY
A 1/8-in.National PipeTaper thread plugged tapping,
accessible for test gauge connection, must be installed
immediatelg upstream of the gas supplg connection to
the drger. Contact sour local gas utilitg should Sou have
questions on the installation of the plugged tapping.
Supplg line isto be 1/2-in. rigid pipe and equipped with an
accessible shut-off within 6 ft. of, and in the same room
with the drger.
Use pipe thread sealer compound or Teflon tape appropri-
ate for natural or LPgas.
You must use with this drger a flexible metal connector
listed connector ANSIZ21.24 / CSA6.10. The length of the
connect shall not exceed 3 ft.
Connect flexible metal connector to drger and gas supplg.
Open shut-off valve.
2
Installation
_] RECONNECTING GAS
Listed connector ANSI Z2!.24 / CSA 6.!0
1/8" NPTPIPE
NEW METAL PLUG FOR
GAS
FLEXIBLEGAS INLETPRESSURE
LINECONNECTOR
ADAPTER
ELBOW
3/8" NPT
SHUT-OFF
PIPE SIZE
ITEMSNOT SUPPLIED _AT LEAST1/2"
Note: The connector and fittings (]re designed for use
onlg on the original installation and (]re not to be reused
for another appliance or at another location. Keep flare
end of adaptor free of grease, oil and thread sealant.
Caution: Use adapters as shown. Connector nuts must
not be connected directlg to pipe threads.
APPLYPIPECOHPOUND
TOTHEADAPTERAND
DRYERGASINLET.
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
Instructions
APPLYPIPECOMPOUND
TOALL HALETHREADS.
TIGHTEN ALL CONNECTIONS
USINGTWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
[-4]LEAK TEST
"WARNING: NEVERUSEAN OPEN
LAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE,
Check oil connections for teaks with soopg solution or equivalent.
Apptg soop solution. Leak test solution must not contain ammo-
nia which could cause damage to the brass fittings. If leaks ore
found, close volve, retighten the joint, and repeGt the soap test.
3
Installation
[-_ ELECTRICAL CONNECTION
INFORMATION
m
WARNING - TOREDUCETHE
RISK OF FIRE, ELECTRICAL SHOCK,
AND PERSONAL INJURY:
. DO NOT USEAN EXTENSIONCORDORAN ADAPTER
PLUGWITH THISAPPLIANCE.
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
ELECTRICALCODE,ANSI/NFPANO.70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V,60Hz, and
connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time-
delay fuse. If electrical supply provided does not meet the
above specifications, it is recommended that a licensed
electrician install an approved outlet.
,A,WARNING -THISDRYERIS
EQUIPPED A THREE-PRONG (GROUNDING)
PLUG FOR YOUR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG FROM
THIS PLUG.
ENSUREPROPERGROUND EXISTSBEFOREUSE.
IF LOCAL CODES PERHIT,
AN EXTERNAL GROUND WIRE
(NOT PROVIDED), WHICH HEETS
LOCAL CODES, HAY BE ADDED
BYATTACHING TO THE GREEN
GROUND SCREW ON THE REAR
OF THE DRYER,AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
Instructions
[-6-]EXHAUST INFORMATION
WARNING -IN CANADAANDINTHE
UNITED STATES,THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 IN (102ram). DO NOT USEDUCT
LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE.
Usingexhaustlongerthan specifiedlengthwill:
Increasethedrying timesandthe energycost.
Reducethe dryer life.
Accumulatelint, creatinga potential firehazard.
Thecorrect exhaustinstallation isYOURRESPONSIBILITY.
Problemsdueto incorrect installation are not covered by
the warranty.
Removeanddiscordexistingplasticor metalfoil transition
duct and replacewith ULlistedtransition duct.
TheMAXIMUMALLOWABLEduct lengthand numberof
bendsof theexhaustsystemdependsupon thetype ofduct,
numberofturns,thetgpe ofexhausthood(wallcap),and all
conditionsnotedbelow.Themaximumduct lengthfor rigid
metal duct isshownin thetable below.
EXHAUST LENGTH
RECOMHENDEDHAXIHUH LENGTH
Exhaust Hood Tgpes
Recommended Use only for short
run installations
4" DIA.
_l J..... 21/2"
No. of 90 ° Rigid
Elbows Metal
0 60 Feet
1 45 Feet
2 35 Feet
3 25 Feet
4 15 Feet
4" J_
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
EXHAUST SYSTEM CHECK LIST
HOOD ORWALL CAP
Terminateina mannerto preventback draftsor entrgof birds
or otherwildlife.
Terminationshouldpresentminimal resistanceto the exhaust
air flow and shouldrequirelittleor nomaintenanceto prevent
clogging.
Never installa screenin or overtheexhaustduct.Thiscould
causelint buildup.
Wallcapsmust beinstalledat least12 in.abovegroundlevel
or any otherobstructionwith the openingpointeddown.
SEPARATIONOFTURNS
Forbest performance,separateallturns bg at least4 ft. of
straightduct, includingdistancebetweenlastturn and exhaust
hood.
TURNSOTHERTHAN90°
Oneturn of 45°or lessmegbeignored.
Two450turns shouldbetreated asone 900turn.
Eachturn over450shouldbetreated asone 900turn.
SEALINGOFJOINTS
Alljointsshouldbetight to avoidleaks.Themaleendof each
sectionofduct must pointawagfrom the dryer.
Donotassembletheductwork with fastenersthat extend into
the duct.Theywillserveasa collectionpointfor lint.
Ductjointscan bemadeair and moisture-tightby wrapping
the overlappedjoints with duct tape.
Horizontalrunsshouldslopedown toward theoutdoors l_inch
per foot
INSULATION
Ductwork that runsthroughan unheatedareaor isnear air
conditioningshouldbe insulatedto reducecondensationand
lintbuild-up.
4
Installation instructions
[_ EXHAUST CONNECTION
WARNING - TOREDUCETHE
RISK OF FIRE OR PERSONAL INJURY:
* This clothes drger must be exhausted to the outdoors,
* Use onlg 4" rigid metal ducting for the home exhaust
duct.
* Use onlg 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-tgpe) duct to connect the drger
to the home exhaust duct. It must be installed
in accordance with the instructions found in
"Connecting The Drger To House Vent" on page 6 of
this manual.
*Do not terminate exhaust in a chimneg, a wall,
a ceiling, gas vent, crawl space, attic, under an
enclosed floor, or in ang other concealed space of
a building. The accumulated lint could create a fire
hazard.
* Never terminate the exhaust into a common duct
with a kitchen exhaust sgstem. A combination of
grease and lint creates a potential fire hazard.
* Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate lint,
creating a potential fire hazard.
*Never install a screen in or over the exhaust duct. This
will cause lint to accumulate, creating a potential fire
hazard.
* Do not assemble ductwork with ang fasteners
that extend into the duct. These fasteners can
accumulate lint, creating a potential fire hazard.
* Do not obstruct incoming or exhausted air.
* Provide an access for inspection end cleaning of
the exhaust sgstem, especiallg at turns and joints.
Exhaust sgstem shell be inspected end cleaned at
least once gear.
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 9 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
STANDARD REAR EXHAUST
{Vented ot floor level}
FORSTRAIGHTLINEINSTALLATION,CONNECTTHEDRYEREXHAUSTTO
THEEXTERNALEXHAUSTHOODUSINGDUCTTAPEORCLAMR
CSA)AGA)APPROVED
NEWFLEXIBLEGAS
LINECONNECTOR
GAS
EXTERNAL
INLET
DUCT
PIPE
OPENING
DUCTTAPEOR
DUCTCLAMP
4IIMETALDUCT
(CUTTOPROPER
LENGTH) DUCTTAPEOR
DUCTCLAMP
NOTE:WE STRONGLYRECOMMENDSOLIDMETALEXHAUSTDUCTING.
HOWEVER,IFFLEXIBLEDUCTINGISUSEDITMUSTBEUL-LISTEDMETAL
NOTPLASTIC.
ELBOWHIGHLY
RECOMMENDED-
STANDARD REAR EXHAUST
(Vented obove floor level}
ELBOWHIGHLY
"-/'-_/¢RECOMMENDED
RECOMMENDED
CONFIGURATION
TOMINIMIZE
EXHAUST
BLOCKAGE,
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
[] LEVELING DRYER
LEVEL
FRONT-TO-BACK,
"-.,.
LEVEL
SIDE-TO-SIDE.
4LEVELINGLEGS
STANDTHEDRYERUPRIGHTNEARTHE
FINALLOCATIONANDADJUSTTHE4 LEVELING
LEGSTOMATCHTHEHEIGHTOFYOURWASHER,
ADJUSTTHE2ANTI-TIPLEGSTOCONTACT
THEFLOOR,
2ANTI-TIPLEGS
5
Installation
CONNECTING THE DRYER
TO HOUSE VENT
RIGIDMETALTRANSITIONDUCT
Forbestdryingperformance,a rigid metaltransitionduct is
recommended.
Rigidmetaltransitionsducts reducethe riskof crushingand
kinking.
UL-LISTEDFLEXIBLEMETAL(SEMI-RIGIDTRANSITIONDUCT
tfrigid metulduct cannot be used,thenUL-listedflexible metul
(semi-rigid)ducting cun beused(KitWX08X10077).
Neverinstullflexible metulduct inwulls,ceilings,floors or
otherenclosedspaces.
Total lengthofflexiblemetal duct shouldnot exceed8 feet
(2.4m).
Formany applications,installingelbowsat boththedryer
undthe wullishighly recommended(seeillustrutionsbelow).
Elbowsullowthe dryerto sit closetothe wallwithout kinking
andor crushingthetransition duct,maximizingdrying
performance.
Avoidrestingtheduct on sharpobjects.UL-LISTEDFLEXIBLE
METAL(FOIL-TYPE}TRANSITIONDUCT
tnspeciulinstullutions,it muy be necessurgto connectthe
dryerto the housevent usingu flexiblemetul(foiltype)duct.
A UL-listedflexiblemetul (foil-type)ductmuy be usedONLY
in instullutionswhererigid metulor flexiblemetul (semi-rigid)
ductingcunnot be usedANDwhereu4" diumeter cun be
muintuinedthroughout theentirelengthof thetrunsition
duct.
tnConuduundthe UnitedStutes,only theflexible metul(foil-
type) ductsthut comply with the "Outlinefor ClothesDryer
TrunsitionDuctSubject2158A"shullbe used.
Neverinstullflexible metulduct inwulls,ceilings,floors or
otherenclosedspuces.
Totul lengthofflexiblemetul duct shouldnot exceed8 feet
(2.4m).
Avoidrestingtheduct on shurpobjects.
Forbest dryingperformunce:
1.Slideone endof theduct overthe clothesdryer
outlet pipe.
2.Securethe ductwith u clump.
3.With the dryer in itspermunent position,extendthe
duct to itsfull length.Allow2"of duct to overlupthe
exhuustpipe.Cut off und removeexcessduct. Keep
theduct usstruight uspossiblefor muximumuirflow.
4.Securethe ductto theexhuustpipewith the other
clump.
ELBOWHIGHLY
REC0
"_<._ _ ELBOWSHIGHLY
d
6
Instructions
DONOTUSE
EXCESSIVE
EXHAUST
LENGTH
F9-1ALCOVE OR CLOSET INSTALLATION
tfyourdryer isapprovedfor installationinan alcoveor closet,
it will bestatedon a labelon thedryer back.
Thedryer MUSTbevented tothe outdoors.Seethe EXHAUST
INFORMATIONsection.
Minimumcleuruncebetweendryercubinet undudjucent
wullsor other surfacesis:
0in.eitherside
3 in.front and rear
Minimumverticalspacefrom floorto overheadcabinets,
ceiling,etc.is52 in.
Closetdoorsmustbe Iouveredor otherwiseventilatedand
mustcontain a minimumof 60sq.in.of openareaequally
distributed,ifthe closetcontainsboth a washeranda dryer,
doorsmustcontain a minimumof 120sq.in,of openarea
equallydistributed.
Theclosetshouldbe ventedtothe outdoorsto preventgas
pocketingincaseof a gasleukin the supplyline.
Nootherfuel-burningapplianceshallbeinstulledinthe some
closetwith thedryer.
I1OIBATHROOM OR BEDROOM INSTALLATION
Thedryer MUSTbevented tothe outdoors.SeeEXHAUST
INFORMATIONsection6.
Theinstullationmustconformwith Ioculcodesor,inthe
ubsenceof Ioculcodes,with theNATIONALFUELGASCODE,
ANSIZ223.
[_]MOBILE OR MANUFACTUREDHOME INSTALLATION
tnstullationmustconformto theMANUFACTUREDHOME
CONSTRUCTION& SAFETYSTANDARD,TITLE24,PART32-80
or,whensuchstundard isnotapplicuble,with AMERICAN
NATIONALSTANDARDFORMOBILEHOME,NO.50lB.
Thedryer MUSTbevented tothe outdoorswith the
terminution securelyfastenedtothe mobilehomestructure.
(SeeEXHAUSTINFORMATIONsection6.)
TheventMUSTNOTbe terminutedbeneuthu mobileor
manufactured home.
Theventduct muteriul MUSTBEMETAL.
KIT14-D346-33MUSTbe usedto uttuch thedryer securelyto
the structure.
TheventMUSTNOTbeconnectedto uny otherduct, vent,or
chimney.
Donot usesheetmetulscrewsor other refusteningdevices
which extendintothe interiorof theexhaustvent.
Provideun openingwith u freeareuof ut leust25sq.in.or
introductionof outsideuir intothe dryer room.
Installation
[f2]DRYER EXHAUST TO RIGHT, LEFT
OR BOTTOM CABINET
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR
HANDS AND ARMS FROM SHARP
EDGES WHEN WORKING INSIDE THE
CABINET. BE SURE TO WEAR GLOVES
/ .......
i
REMOVE
SCREW
ANDSAVE.
REMOVEjO
DESIRED
KNOCKOUT
(ONEONLY).
Detach and remove the bottom, right or left side knockout
us desired. Remove the screw inside the drger exhaust duct
and save. Pull the duct out of the dryer.
Note: Only 4" round rigid metal ducting allowed inside
dryer. FIXINGHOLE
B A
9"
Cut the duct as shown and keep portion A.
TAB LOC/_TION
BENDTAB
UP45o
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45o using a flat
blade screwdriver.
Instructions
ADDING NEW DUCT
FIXING
HOLE
PORTION"A"
LEFTSIDE
EXHAUST
Reconnectthe cut portion (A)of the duct to the blower
housing. Makesurethat the shortened duct isaligned with
the tab inthe base.Usethe screw saved previouslgto secure
the duct in placethrough the tab on the appliance base.
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT SIDE OF CABINET
. Preassemble 4" elbow with 4" duct. Wrap duct tope
around joint.
. Insert duct assemblg, elbow first, through the side
opening and connect the elbow to the drger internal
duct.
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the
duct.
DUCT
TAPE
, Applg duct tape as shown on the joint between the
drger internal duct and the elbow.
,TAPE CAUTION:
Internal ductjoints must be
secured with tape, otherwise
they may separate and cause
a safety hazard.
7
Installation
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
, Insert the elbow through the rear opening and connect
itto the drger internal duct.
Applg duct tape on the joint between the drger internal
duct and elbow, us shown on page 7.
.J
CA
Internal duct joints must be secured with tape,
otherwise they may separate and cause a
safety hazard.
ADDING COVER PLATE TO REAR OF
CABINET
PLATE
(KITWE1H858)
Connect standard metal elbows and ducts to complete
the exhaust sgstem. Cover back opening with a plate (Kit
WE11V1454)available from gout local service provider.
Placedrger in final location.
,_WARNING-NEVER LEAVE THE BACK
OPENING WITHOUT THE PLATE.
Instructions
CHANGING DIRECTION OF
DOOR OPENING
REMOVE4
HINGESCREWS.
REMOVE/4HOLEPLUGSAND
PLACETHEIViINTHEHOLES
ONTHEOPPOSITESIDE.
ROTATEDOOR1800
ANDREINSTALL.
8
Installation
[_] CONNECTING INLET HOSES
(onsome models)
To produce steam, the drger must connect to the cold
water supplg. Sincethe washer must also connect to the
cold water, a "`7"connector is inserted to allow both inlet
hoses to make that connection at the some time.
NOTE:Use the new inlet hoses provided; never
use old hoses.
1.Turn the cold water faucet off. Removethe washer inlet
hose from the washer fill valve connector (cold).
2. Ensurethe rubber fiat washer isin place and screw
the female coupling of the short hose onto the washer fill
valve connector. Tighten bg hand until firmlg seated.
3. Attach the female end of the ",7"connector to the male
coupling of the short hose. Ensurethe rubber fiat washer
is in place. Tighten bg hand until firmlg seated.
4. Insert the filter screen in the coupling of the washer's
inlet hose. If a rubber fiat washer
isalreadg in place remove it before installing
the filter screen. Attach this coupling to one male end of
the "`7"connector. Tighten bg hand until firmlg seated.
5. Ensurethe rubber fiat washer isin place and attach
the drger's long inlet hose to the other male end of the
"`7"connector. Tighten bg hand until firmlg seated.
6. Ensurethe rubber fiat washer isin place and attach
the other end of the drger's long inlet hose to the fill valve
connector at the bottom of the drger back panel. Tighten
bg hand until firmlg seated.
7. Using pliers, tighten all the couplings with
an additional two-thirds turn.
NOTE:Do not overtighten. Damage to the couplings mag
result.
Instructions
[_ CONNECTING INLET HOSES {cont.}
8. Turn the water faucet on.
9. Check for leaks around the '"7" connector,
faucet and hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUSTbe installed within z_2
in. (107 cm) of gour washer's water inlet. The faucets
MUSTbe 3//4 in. (1.9cm) garden hose-tgpe so inlet hoses
can be connected. Water pressure MUSTbe between 10
and 120 pounds per square inch. ,Tourwater department
can advise gou of gour water pressure.
NOTE:A water softener is recommended to reduce
buildup of scale inside the steam generator if the home
water supplg isverg hard.
[_]SERVICING
WARNING- LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS
OPERATION AFTER SERVICING/
INSTALLATION.
For replacement parts and other information, refer to
Owner's Manual for servicing phone numbers.
For Questions on Installation, Call: 1-800-626-2000 (US)or
1-800-561-33/4/4(Canada).
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Hotpoint HTDX100GM0WW Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI