This device is a lighting adapter that can be used to connect downlights or exit signs to a power source. It has a male (power-in) and a female (power-out) configuration and is designed to be mounted directly to the fixture body in a standard 1/2" K.O. (7/8" diameter). The adapter can be rotated for ease of cable orientation to prevent strain on the connection.

The adapter is made of a die cast housing with a zinc plated steel cover plate and is 2 13/16" x 2 13/16" x 13/16" when installed.

Lightolier Power-Connect La Cable

This device is a lighting adapter that can be used to connect downlights or exit signs to a power source. It has a male (power-in) and a female (power-out) configuration and is designed to be mounted directly to the fixture body in a standard 1/2" K.O. (7/8" diameter). The adapter can be rotated for ease of cable orientation to prevent strain on the connection.

The adapter is made of a die cast housing with a zinc plated steel cover plate and is 2 13/16" x 2 13/16" x 13/16" when installed.

APPLICATION DIMENSIONS
2-5/16"
3/4"
The fixture adapter is the link between the wiring distribution and the fixture
ballast(s). It mounts directly to the fixture body in a standard 1/2" K.O. (7/8"
diameter). The adapter can be rotated for ease of cable orientation to prevent
a strain on the connection.
LA
POWER-CONNECT™ LA CABLE
Page 1 of 2 LIGHTING ADAPTERS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 OPTIONS/ACCESSORIES/Folio OA40-17
FEATURES
For feeding downlights or exit signs.
Male (power-in) and female (power-out)
configuration.
Adapter is 2 13/16" x 2 13/16" x 13/16" installed.
Die cast housing with zinc plated steel cover plate.
Fixture adapters can be wired for single or multi-level use.
Thru wired for three circuits.
Type 6M adapter wires are #18 AWG TFN solid copper conductors,
600 volt.
Type 7M adapter wires are #12 AWG THHN stranded copper
conductors, 600 volt.
Type 6M and 7M have 6 inch tap leads.
1/2" K.O. connector for mounting to fixture.
WIRING DIAGRAM
ORDERING INFORMATION
Explanation of Catalog Number. Example: LP–LA–12–6–3
SPECIFICATIONS
Fixture adapter can be wired for single or multi-level use.
1/2" K.O. connector for mounting to fixture.
Adapter is 2 13/16" x 2 13/16" x 13/16" installed.
Die-cast housing with zinc plated steel cover plate.
Thru-wired for three circuits.
Type 6M adapter wires are #18 AWG TFN solid copper
connectors, 600 volt.
Type 7M adapter wires are #12 AWG THHN stranded copper
conductors, 600 volt.
Type 6M and 7M have 6 inch tap leads.
LALP
TYPE:
LA =Lighting
Adapter
LOL POWER
CONNECT
WIRING
CONFIGURATION:
6=#18 Tap Wires
7=#12 Tap Wires
M=Multi-level
A=“A” Phase Tap
B=“B” Phase Tap
C=“C” Phase Tap
VOLTAGE:
12 - 120v
27 - 277v
LENGTH:
3=3 inches,
standard length
of flex
XX=Other length
of flex
“A” PHASE TAP
“B” PHASE TAP
“C” PHASE TAP
TWO CIRCUIT
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 OPTIONS/ACCESSORIES/Folio OA40-17
Job Information Type:
POWER-CONNECT™ LA CABLE
Page 2 of 2 LIGHTING ADAPTERS
  • Page 1 1
  • Page 2 2

Lightolier Power-Connect La Cable User manual

Category
Coaxial cables
Type
User manual
This manual is also suitable for

Lightolier Power-Connect La Cable

This device is a lighting adapter that can be used to connect downlights or exit signs to a power source. It has a male (power-in) and a female (power-out) configuration and is designed to be mounted directly to the fixture body in a standard 1/2" K.O. (7/8" diameter). The adapter can be rotated for ease of cable orientation to prevent strain on the connection.

The adapter is made of a die cast housing with a zinc plated steel cover plate and is 2 13/16" x 2 13/16" x 13/16" when installed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI