Lightolier EZ-Connect Cables "D" Series allow for quick and easy field installation by plugging ballast leads into “Poke Home” connectors, eliminating the need for wirenuts. These cables snap into standard 1/2" knockouts and add a maximum of 7/8" to fixture height. Available in 1, 2, or 3 circuits, EZ-Connect cables are suitable for use in return air spaces above suspended ceilings and are rated for 20 amp 120 and 277-volt lighting circuits.

Lightolier EZ-Connect Cables "D" Series allow for quick and easy field installation by plugging ballast leads into “Poke Home” connectors, eliminating the need for wirenuts. These cables snap into standard 1/2" knockouts and add a maximum of 7/8" to fixture height. Available in 1, 2, or 3 circuits, EZ-Connect cables are suitable for use in return air spaces above suspended ceilings and are rated for 20 amp 120 and 277-volt lighting circuits.

POWER-CONNECT
RC CABLE
Page 1 of 2 EZ-CONNECT CABLES, “D” SERIES
APPLICATION DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 OPTIONS/ACCESSORIES/Folio OA40-10
Features
Combination of external fixture adapter and armored cable.
Cables can be rotated 180° in either direction for proper cable orien-
tation to prevent strain on connection.
Suitable for use in return air spaces above suspended ceilings in
accordance with 1999 N.E.C. 300-22 (c) and 604-3.
Rated for 20 amp 120 and 277 volt lighting circuits.
Connector polarized and color-coded for voltage function to prevent
mismating of components.
#12 AWG THHN stranded copper, 600 volt.
Fixture taps that are #18 AWG TFN solid copper conductors, con-
nected to “Poke-Home” connectors.
Positive latching steel spring latches engage with easy push action.
Pin and socket contacts.
Meets UL requirements for making or breaking under load.
I.B.E.W./UL and C-UL labeled.
9/16"
5/8"
*When installed, RC cable adds 7/8" to fixture height.
Quick and easy field-installed by plugging ballast leads into
“Poke Home” connectors, no wirenuts required.
Snaps into standard 1/2" knockout.
EZ-Connect cables add maximum of 7/8" to fixture height,
available in 1, 2 or 3 circuits.
3/4"
2-5/16"
1-11/16"
POWER-CONNECT
RC CABLE
Page 2 of 2 EZ-CONNECT
CABLES, “D” SERIES
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 OPTIONS/ACCESSORIES/Folio OA40-10
Job Information Type:
SPECIFICATIONS
UL and C-UL Listed.
• IBEW labeled.
Suitable for use in return air spaces above suspended ceilings in
accordance with 1999 N.E.C. 300-22 (c) and 604.3.
Meets UL requirements for making or breaking under load.
Pin and socket contacts.
Rated for 20 amp 120 and 277 volt lighting circuits.
Connector polarized and color-coded for voltage function to prevent mismat-
ing of components.
#12 AWG THHN stranded copper, 600 volt.
Fixture taps that are #18 AWG TFN solid copper conductors, connected to
“Poke-Home” connectors.
Positive latching steel spring latches engaged with easy push action.
WIRING DIAGRAM WIRING
ORDERING INFORMATION
Explanation of Catalog Number. Example: LP–RC–12–1D–05
RCLP
TYPE:
RC =EZ-Connect™
Cable
LOL POWER
CONNECT
WIRING
CONFIGURATION:
1D - 1 Circuit
2D - 2 Circuit
3D - 3 Circuit
ND - 2 Cir., 2 Neu.
VOLTAGE:
12 - 120v
27 - 277v
LENGTH:
05 - 5'
07 - 7'
09 - 9'
11 - 11'
13 - 13'
17 - 17'
21 - 21'
25 - 25'
30 - 30'
5
4
3
2
1
POWER IN
POWER OUT
GROUND
WHITE
BLACK
5
4
3
2
1
a
b
d
5
4
3
2
1
POWER IN
POWER OUT
GROUND
RED
BLUE
NEUTRAL
BLACK
5
4
3
2
1
a
bd
e
5
4
3
2
1
POWER IN
POWER OUT
GROUND
RED
WHITE
BLACK
5
4
3
2
1
a
bd
e
THREE CIRCUIT
TWO CIRCUITONE CIRCUIT
(Typical)
• Black lead to outboard ballast lead.
• Red lead to inboard ballast lead.
• White lead to white ballast leads.
a
b
c
d
e
black
white
blue
ground
red
WIRING COLOR LEGEND
Panelboard Switching (Typical)
Local Switching (Typical)
  • Page 1 1
  • Page 2 2

Lightolier "D" Series User manual

Type
User manual
This manual is also suitable for

Lightolier EZ-Connect Cables "D" Series allow for quick and easy field installation by plugging ballast leads into “Poke Home” connectors, eliminating the need for wirenuts. These cables snap into standard 1/2" knockouts and add a maximum of 7/8" to fixture height. Available in 1, 2, or 3 circuits, EZ-Connect cables are suitable for use in return air spaces above suspended ceilings and are rated for 20 amp 120 and 277-volt lighting circuits.