CAME RBM Installation guide

  • Hello! I've analyzed the CAME RBM84 Access Control System Configuration Manual. It contains detailed instructions on system configuration, user management, sensor setup, and more. I'm ready to answer any questions you might have about using the RBM84 access control system described in the document.
  • How do I update the firmware of the RBM84 card?
    How do I set the language for the software?
    What is the function of the 'Update!' symbol?
    How do I assign a name to the outputs?
    What should I do if a communication error is reported?
CONFIGURATION MANUAL
RBM84 - SW
ACCESS CONTROL
SYSTEM
119RV02EN
En
g
lis
h
E
N
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
2
Page
2
2 - Manual code:
119RV02
119 RV02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Software installation .........................................................................................................................................................................4
Software menu RBM84 .....................................................................................................................................................................5
RBM84 card fi rmware update ...........................................................................................................................................................5
Software language setting ................................................................................................................................................................6
Main dialogue window ......................................................................................................................................................................6
System confi guration window ..........................................................................................................................................................7
PC30 confi guration ...........................................................................................................................................................................8
Select the REM number connected to the RBM84 card .....................................................................................................................9
Assign a name to the outputs connected to RBM84 and REM/TOR ....................................................................................................9
Defi ne user groups .........................................................................................................................................................................10
Pass based entry ............................................................................................................................................................................11
Tra c light setting (if any) ...............................................................................................................................................................12
Confi gure the control sensors connected to the RBM84 ..................................................................................................................13
Sensor type ....................................................................................................................................................................................13
Sensor function ..............................................................................................................................................................................13
Associating a sensor to an exit ........................................................................................................................................................14
Associating a sensor to tra c light control ......................................................................................................................................14
Fee Function (varying charge) .........................................................................................................................................................15
Associating a sensor to a user group ..............................................................................................................................................16
Activating the outputs of RBM84 .....................................................................................................................................................17
Relay function .................................................................................................................................................................................18
Confi guring the digital inputs connected to RBM84 .........................................................................................................................19
Associate the digital devices to the outputs .....................................................................................................................................19
Confi guring the REM .......................................................................................................................................................................20
Assign name to REM .......................................................................................................................................................................20
Confi gure the control sensors connected to the RBM84 ..................................................................................................................21
Type of sensor (REM) ......................................................................................................................................................................21
REM sensor function .......................................................................................................................................................................21
Associating a sensor to an output (REM) .........................................................................................................................................22
Associating a sensor to tra c light control (REM) ............................................................................................................................22
Fee Function (varying charge) (REM) ...............................................................................................................................................22
Associating a sensor to a user group ..............................................................................................................................................23
Confi guring the REM outputs ..........................................................................................................................................................24
Activating the outputs of RBM84 .....................................................................................................................................................24
Relay function .................................................................................................................................................................................25
Assigning digital devices to a REM output .......................................................................................................................................25
Confi guring the REM digital inputs ..................................................................................................................................................25
Confi guring the TOR .......................................................................................................................................................................26
Assigning a name to TOR ................................................................................................................................................................26
Confi gure the control sensors connected to the TOR .......................................................................................................................27
Type of sensor (TOR) .......................................................................................................................................................................27
TOR sensor function .......................................................................................................................................................................27
Associating a sensor to an output (REM) .........................................................................................................................................28
Associating a sensor to tra c light control (TOR) ............................................................................................................................28
Associating a sensor to a user group ..............................................................................................................................................29
Confi guring the TOR outputs ...........................................................................................................................................................30
Wave confi guration .........................................................................................................................................................................31
Sensor function ............................................................................................................................................................................31
Associating a sensor to an exit ........................................................................................................................................................31
Associating a wave sensor to tra c light control .............................................................................................................................32
Fee Function (varying charge) .........................................................................................................................................................32
Associating a sensor to a user group ..............................................................................................................................................33
System timer confi guration window (REM) ......................................................................................................................................34
Rate confi guration window .............................................................................................................................................................35
Prepaid values ................................................................................................................................................................................35
Discount level .................................................................................................................................................................................35
Confi guration page of User time slots. .............................................................................................................................................36
SUMMARY
TOPIC PAGE
Ch. 1 - System configuration
Ch. 2 - Timing configuration
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
3
Page
3
3 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Locked days confi guration window .................................................................................................................................................37
Confi guration page of scheduled openings and "antipassback".......................................................................................................38
Confi guring Standard Schedules Access .........................................................................................................................................39
Free time slot confi guration ............................................................................................................................................................40
General notes .................................................................................................................................................................................42
User confi guration window .............................................................................................................................................................43
Recording a NEW USER ...................................................................................................................................................................44
USER CODE memorisation window ................................................................................................................................................45
USER CODE memorisation .............................................................................................................................................................46
Code memorisation on sensors .......................................................................................................................................................47
Code operating mode ......................................................................................................................................................................47
Memorising a code from a pass .....................................................................................................................................................48
Access validity ................................................................................................................................................................................48
ACCESS mode confi guration ...........................................................................................................................................................49
NORMAL access mode ....................................................................................................................................................................50
Antipassback ..................................................................................................................................................................................51
PREPAID access mode ....................................................................................................................................................................52
TIME SLOT PREPAID access mode ..................................................................................................................................................54
Adding a set number of users (New sequence)................................................................................................................................55
Adding a set number of users (RW Sequence) .................................................................................................................................57
Checking user status ......................................................................................................................................................................58
RBM84 Updates ..............................................................................................................................................................................60
Display preferences ........................................................................................................................................................................61
Managing statistics .........................................................................................................................................................................61
Statistics (EVENTS) .........................................................................................................................................................................62
Daily management ..........................................................................................................................................................................64
PRINT window ................................................................................................................................................................................66
Print preview window .....................................................................................................................................................................67
Entering master password ..............................................................................................................................................................70
Modify and deactivate master password. ........................................................................................................................................70
Entering card password ..................................................................................................................................................................71
Access to a password protected card ..............................................................................................................................................71
Entering operator password ............................................................................................................................................................72
System lock-up ..............................................................................................................................................................................74
Project management .......................................................................................................................................................................74
System installer information ...........................................................................................................................................................75
Project history ................................................................................................................................................................................75
User presence ................................................................................................................................................................................76
Occasional users ............................................................................................................................................................................77
Occasional user presence ...............................................................................................................................................................78
Connection from remote computer ..................................................................................................................................................79
Remote connection window ............................................................................................................................................................80
How to connect a modem remotely after activating the connection window ....................................................................................80
SUMMARY
TOPIC PAGE
Ch. 3 - User configuration
Ch. 4 - Updates - daily statistics
Ch. 5 - Printouts
Ch. 6 - Password
Ch. 7 - Lock presence project management
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
4
Page
4
4 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Software installation
Insert the CD-ROM into the drive and wait for the
installation window (or launch the fi le
setup.exe
from the
folder
RBM84 st. 3.x
on your PC, if you copied locally).
After selecting the language of your choice, follow the
instructions in the installation procedure on the screen.
CAUTION! Windows 7 and Windows 8
users must change software installation
path by creating a new folder on local
drive C:\.
Minimum system requirements:
Operating System: Windows XP Professional / Windows 7 Professional / Windows 8 Professional;
RS232 serial port (alternatively use a USB/RS232 converter by installing the appropriate drivers).
The name of the
installation folder can be
customised.
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
5
Page
5
5 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
"File” Menu
"Version" = opens a window which shows the software version.
"End" = command to close the program.
“Preferences” Menu
For information about this menu, see Chapter 4, page 61
“Events” Menu
For information about this menu, see Chapter 7, page TT
To update the fi rmware of the RBM84 cardd, click on:
"Tools" -> "Updates" and wait for window to open.
This area shows the name of
the update fi le.
Number of the new version
available.
Shows the software version
number.
To begin the upgrade, click on
this button and wait for the
completion of the upgrade
process
Update bar progress
Exit key
from update
Software menu RBM84
RBM84 card fi rmware update
1
13
14
15
18
2 3 4 5 6 7 8 9 10 11 12 16 17
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
6
Page
6
6 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Before confi guring Rbm84 select the language.
1. System confi guration window toggle key
2. Timer window toggle key
3. User confi guration window toggle key
4. System updating window toggle key
5. Statistics window toggle key
6. Daily stats window toggle key
7. Printout window toggle key
8. Password window toggle key
9. Acoustic alarm deactivation key
10. System Lock-up/Release key
11. Project management window toggle key
12. Occupants window toggle key
13. Communicating Rem (green)
14. Non-communicating Rem (red)
15. Last 4 entrances display window (in real-time)
16. Rbm84 digital input and output section
17. Tra c light section, shows connected tra c lights and status.
18. Luminous box shows communication with card
Main dialogue window
Software language setting
CAUTION! At the end of each set of operations UPDATE to make changes e ective. This symbol will serve as
reminder at every subsequent sensitive procedure!
Update!
2 3 4 51
7 86 9 10 11
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
7
Page
7
7 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
1. Rbm84 confi guration folder
2. Rem/TOR confi guration folder
3. Rbm84 output /relay output) confi guration folder
4. Rbm84 digital input confi guration folder
5. Wave confi guration folder
6. Confi rm changes key
7. Cancel changes key
8. Save key
9. Rbm84 save confi gurations key
10. Rbm84 read confi gurations key
11. Exit key
System confi guration window
1
2
3
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
8
Page
8
8 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Click x 2
The COM available on PC can be
seen once the window is open.
In the configuration screenpage “PC30”, you must select the PC input port that connects Pc30 (usually COM1).
Caution! This should be done before starting any programming and / or configuration
described in the following pages and the sections that follow, otherwise the
software, at any request of updating/saving, will report a COMMUNICATION ERROR.
PC30 confi guration
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
9
Page
9
9 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
In the Rbm84 card, Confi guration area, set the number of Rem/TOR connected, clicking on "N. REM" and using the arrows.
(clicking the arrow increases the
Rem/TOR number one unit at a time)
Click x 1
Click "Output Name"
Type, in the "OUTPUT DEFINITION" box, the name desired for the
outputs connected to Rbm84 and Rem/TOR
This procedure is optional: the system assigns a default
name for each output available in the system "from "Output
1" to "Output 128).
(The fi rst 8 outputs are for Rbm84 land the others for Rem/TOR)
We recommend giving a name to each output in order to
simplify subsequent confi guration operations.
Select the REM number connected to the RBM84 card
Assign a name to the outputs connected to RBM84 and REM/TOR
Update!
Update!
2
1
3
4
5
6
7
8
9
10
11
12
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
10
Page
10
10 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
1. Click "Confi gure Group"
2. Select group to set
3. Assign name to selected group
4. Assign a function to single group:
Disabled allows no operation to the entire group
Entry / Exit allows standard entry / exit operations to the group
Security allows entry at any time, even if the access is performed during locked time slots.
Privileged allows entry to a specifi cally created group, even if the access is performed during locked
time slots.
5. Select day to set.
6. Select time slot to set.
7. Assign a function to the single time slot:
Enabled allows the group to enter and exit in the set time slot
Locked no entry or exit allowed
Input allows only entry in the time slot set
Exit allows only exit in the time slot set
8. Select time slot start time
9. Select time slot end time
10. Associate a credit value to the time slot.
11. The "Copy" button duplicated settings for all days of the week.
12. Click "OK" once settings are complete.
Defi ne user groups
Update!
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
11
Page
11
11 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Pass based entry
With parking pass use, ir is possible to confi gure the zones inside the main system, which are accesses with di erent fees.
For example, a sports centre where the main fee is pay per time, can have other areas where the fee is calculated as a fi xed amount
each time.
Example of use
Sensor 1
Function: Entry
Sensor 4
Function: Exit
Sensor 3
Function: Internal access
The sensors of the sites must be confi gured according to "Internal
Access", assigning them relative fi xed cost (System confi guration
RBM84 Local sensors, p. 15)
Select time slot to associate with entry with pass ( System
confi guration group confi guration associated time
slot, p. 10)
Lastly, confi gure the users that can access these zones,
with Prepaid access, Personnel access group
time slot, Fee Time slots and Apb In/out. (User
confi guration Access, p. 52)
Sensor 2
Function: Internal access
SAUNA POOL
GYM
1
2
3 4 5 6
7
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
12
Page
12
12 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
1. Click "Tra c lights"
2. Select tra c light to set.
3. Assign name to selected tra c light
4. Assign a maximum number of spaces to parking
5. If there are occupied parking during installation, simply mark these in the occupied box.
6. Select type of function:
Autonomous the tra c light is considered independently and not counted in total
Full the tra c light is part of a group of lights, when all are full the system will signal full
7. Click to set the values assigned to the tra c light selected.
Caution: after setting name and parameters of the tra c light, click on the left arrow otherwise the new parameters entered will
not be recorded when changing tra c light.
Tra c light setting (if any)
Update!
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
13
Page
13
13 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
In the area "Local Sensors" of the Rbm84 card, the type,
function and association of each control device connected to
the Rbm84 must be confi gured. The sensor number corresponds
with the sensor connected to the terminal block and marked
with the same number, see fi gure.
In the "Type" dropdown menu select the type of sensor
connected:
- Disabled
- Keypad S5000/S6000/S7000
- Radio T432A/T302A/TAM
- Rolling code “Atomo”
- Transponder TSP00/LT001
- Radio T432M/S
and confi rm with "OK"
In the "Function" dropdown menu select the function of the
sensor connected:
- Entry / Exit
- Entry
- Exit
- Internal access
- Entry with credit pass (prepaid pass)
- Exit with credit pass (prepaid pass)
and confi rm with "OK"
Sensor function
Sensor type
Confi gure the control sensors connected to the RBM84
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
14
Page
14
14 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
In the dropdown menu "Association", select the match of the
sensor to one of the sensors connected at confi rm with "OK"
In the dropdown menu "Parking", select the parking to which
the sensor will be associated and confi rm with "OK"
Associating a sensor to an exit
Associating a sensor to tra c light control
1
2
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
15
Page
15
15 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
1. Setting the sensor with “Internal Access” function.
2. Assigning the value associated to the sensor.
N.B.: This function is applied only to access of a controlled internal area to a controlled main area. (See ch. 1 p. 11)
Fee Function (varying charge)
Update!
1
2
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
16
Page
16
16 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
1. Click "Group".
2. Tick the group of users, in the "Group" window, to which the device will be associated and confi rm with "OK".
Caution! This is not an optional procedure, at least one group must be ticked. The "All" button (dis)associates all user
groups to the device.
The BLUE numbers are enabled groups, while RED are disabled.
The "All" button
(dis)associates all user
groups to the device.
Associating a sensor to a user group
Update!
1
2
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
17
Page
17
17 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Confi guring the outputs connected to Rbm84
The outputs connected to Rbm84 in the “Ooutputs”
card must be programmed with the type of function and
activation time of the relative relay;
If no operators are connected, select or leave "Disabled"
as proposed in the menu.
The output number corresponds with the sensor
connected to the terminal block and marked with the
same number, see fi gure.
1. Select output (1÷8).
2. Associate the output to one of the names/
devices in the dropdown menu
The dropdown menu of the "Local Exits" area show the tra c light and normal exits by default as defi ned in "Assigning
a name to outputs".
The output/control device match is independent of the physical connection of the latter on Rbm84 or Rem;
Activating the outputs of RBM84
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
18
Page
18
18 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
Bistable relay
No time adjustment
The relays of the Rbm84 card can be set in
"Monostable" or "Bistable"
When in Monostable, relay triggering time can be set
(from 1 second to 10 minutes).
Relay function
Update!
1
2
3
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
19
Page
19
19 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
All additional command and control devices (such
as safety buttons, sensitive mats, alarms, etc.) must be
programmed in the digital inputs confi guration card that
are connected to Rbm84 and that act on any output,
whether Rbm84 or Rem.
N.B. There are also di erent functions from those that are
standard outputs:
-Lock
-Alarm input
-Alarm reset
-Parking input
-Parking output.
Select, for each input, an output/device that will receive the
action of said digital device; tick the relative box if the device
contact is NC (normally closed).
1. Select the input to set
2. For each input assign an output/device
3. Tick the relative box if the device is N.C. type
The digital input/output match is independent of
the physical connection of the latter on Rbm84 or Rem;
Associate the digital devices to the outputs
Confi guring the digital inputs connected to RBM84
Update!
ACCESS CONTROL SYSTEM -
CONTROL SOFTWARE
20
Page
20
20 - Manual code:
119RV02
119 RV 02 ver.
2
2 01/2014 © CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
Ch. 1 -
System confi guration
In the Rem confi guration car, program,
as for Rbm84, all control devices, and
digital I/O connected;
to switch between Rem, click on the yellow
arrow or icon.
Example of REM icon window: can be green (=
communicating), or red (= non-communicating)
The name entered serves to recognise the output:
this makes it possible to display the event log at entry
in order.
Confi guring the REM
Assign name to REM
/