Dixon Compact Sight Glass Seal Change User manual

  • Hello! I am an AI chatbot trained to assist you with the Dixon Compact Sight Glass Seal Change User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Compact Sight Glass Seal Change Procedure
© 2017 DV Printed in the USA CSGS117_inhouse
Dixon Sanitary
N25 W23040 Paul Road • Pewaukee, WI 53072
ph: 800.789.1718 • 262.513.6900 • fx: 800.789.4046 • 262.513.4904
dixonvalve.com
connect with us on
For ease of assembly and disassembly, clamp an end
cap onto the sight glass body ferrule.
Secure capped end in bench vise.
Using proper hex key, remove top cap set screw.
Using supplied Dixon wrench, rotate the sight glass
top cap clockwise for assembly or counterclock-
wise for disassembly.
Lift off top cap to expose elastomers and glass
insert.
Inspect components and replace if necessary.
For assembly of sight glass, tighten top cap to
compress elastomers until they begin to protrude
inside.
Install set screw.
/