HILLS ESHIELD E SHIELD WW R200 10BEAMS 15M (Cream Colour Only) Technical Manual

Type
Technical Manual

This manual is also suitable for

HILLS ESHIELD E SHIELD WW R200 10BEAMS 15M (Cream Colour Only) is a 10-beam active infrared multi-beam sensor designed to detect intrusions by creating a curtain of infrared beams between a transmitter and a receiver. When one or two adjacent beams are interrupted, the sensor triggers an alarm. With a selectable range of 5-15 meters for external installations and 10-30 meters for internal installations, it is suitable for protecting a variety of areas, including windows, doors, ceilings, skylights, and roller doors.

HILLS ESHIELD E SHIELD WW R200 10BEAMS 15M (Cream Colour Only) is a 10-beam active infrared multi-beam sensor designed to detect intrusions by creating a curtain of infrared beams between a transmitter and a receiver. When one or two adjacent beams are interrupted, the sensor triggers an alarm. With a selectable range of 5-15 meters for external installations and 10-30 meters for internal installations, it is suitable for protecting a variety of areas, including windows, doors, ceilings, skylights, and roller doors.

Active Infrared Multi Beam Sensors
R Series
TECHNICAL MANUAL
INDEX
GENERAL SAFETY RECOMMENDATIONS 3
CONFORMITY 4
WARRANTY 4
INTRODUCTION 5
FEATURES 5
OPERATIONAL RANGE 6
SETUP TRANSMITTER (TX) 6
SETUP RECEIVER (RX) 7
INSTALLATION 7
ALIGNMENT 8
ORIENTATION 8
TAMPER PROTECTION 8
MULTI BEAM INSTALLATIONS 9
CONNECTION 9
BRACKET DESCRIPTION 10
2
GENERAL SAFETY RECOMMENDATIONS
2
Safety Warnings
Read and follow the instructions - Read the installation instructions before
connecting the system to its power source. Follow these guidelines to ensure
general safety. In order to prevent injury, burns or electrical shock to yourself
and others, follow the connection instruction plan carefully.
Product Safety
Do not use the product in a wet location.
Never push a foreign object through an opening inside the product.
Slots and openings are provided for ventilation and should never be covered.
Do not place under direct sunlight or heat sources.
3
CONFORMITY
The infrared barriers R series e conforms with the essential requirements set out by:
89/336/EEC
Electromagnetic compatibility directive
73/23/EEC
Low voltage directive modified by
93/68/EEC Low voltage directive
WARRANTY
These products are warranted against defective parts and workmanship for twelve months from
date of purchase. If any defect appears during the warranty period return it to the place of
purchase. We assume no liability for consequential or indirect damage and accept no
responsibility for repairing damage to the product caused by misuse, careless handling, or where
others have made repairs.
Disclaimer
The content of this document has been prepared to the best of our knowledge, provided “as is” and is
subject to change without notice. Hills Industries does not guarantee technical accuracy beyond the
date of publishing. For the latest information please enquire about attending one of our Hills Reliance
training courses.
4
INTRODUCTION
The R-Series are multi beam active infrared sensors, consisting of a transmitter unit that sends
syncronised beams of infrared light to a receiver unit, which evaluates this stream of infrared
continuously. An alarm signal is generated when either a single beam or two adjacent beams are
interrupted simultaneously (depending on setup).
R-Series are available in 3, 4, 6, 8 and 10 beam configurations with lengths varying from 560mm to
2000mm and offer exceptional performance and stability in both internal and external environments.
They are ideal for protecting single windows, a series of windows, doors, ceilings, skylights, roller doors
or anywhere where a curtain of protection would enhance the ability of early intruder detection.
R-Series are simple to adjust using the multidirectional swivel bracket that allows 180 degrees of
alignment. The onboard alignment buzzer and LED will simplify installations, just align the bottoms of
the beams on the same plane, making sure the two e-shields are parallel with each other. Then aim the
two e - shields at each other and lock in place once correct alignment has been achieved.
FEATURES
Durable aluminum casing, with UV treated high impact resistant PVC ends.
Stock colour is white, whilst other colours are available on request. (a small surcharge and minimum
order quantities will apply)
Model Beams Length Width Depth Coverage External Coverage Internal
R056 3 560 28 22 Selectable 5 – 15M Selectable 10 – 30M
R076* 4 760 28 22 Selectable 5 – 15M Selectable 10 – 30M
R112 6 1120 28 22 Selectable 5 – 15M Selectable 10 – 30M
R152* 8 1520 28 22 Selectable 5 – 15M Selectable 10 – 30M
R200 10 2000 28 22 Selectable 5 – 15M Selectable 10 – 30M
*denotes non stock, special order beams Table 1
Length dimensions shown are with PVC end caps in place.
Operating voltage: 10.5Vdc to 16Vdc
Operating current: max 95mA
Tripping time:100ms
Relay output: NC contacts, 50V AC/DC 120mA
Temperature range: -25°C to +55°C
Degree of protection: IP65
5
OPERATIONAL RANGE
The range depends on the alignment, reflections and environmental brightness. The TX unit offers 4
selectable range settings, 5 – 15M for external installations and 10 – 30M for internal installations.
Range settings are achieved by placing links on “S1” and “S2” to correspond to your requirements from
table 3 .
Caution: Excessive power can compromise the beams integrity by generating too much Infrared signal,
which might cause reflections from surrounding objects, and insufficient infrared signal can produce
unwanted alarms from bright light from surrounding areas. First identify the minimum level required to
operate the e – Shield, then step the power up to the next setting and thoroughly re-test the system.
Transmitter Setup
Buzzer
Table 2
Transmitter Setup - Range
JMP S1 JMP S2
Indoor Outdoor
10m 5m
16m 8m
24m 12m
Range
30m 15m
Buzzer control
Buzzer disabled
Buzzer enabled
JMP 2
Number of beams
required to be
interrupted to activate
alarm
Activates alarm if any beam is
Interrupted
Activates ONLY if 2 adjacent
beams are interrupted
Jumpers marked S1, S2, JMP2 and Buzzer are located on the inner pcb Table 3
6
Receiver Setup
JMP 1
LED Operation
LED will be ON if power is present and
beams are aligned
LED flashes when beams are
broken
LED OFF if power is present
and beams are aligned
LED flashes when beams are
broken
JMP 2
Number of beams
required to be
interrupted to activate
alarm
Activates alarm if any beam is
Interrupted
Activates alarm ONLY if 2
adjacent
beams are interrupted
Jumpers marked JMP 1 and JMP2 are located on the inner pcb Table 4
INSTALLATION
Remove rubber cover cap (No 1 in Figure 5)
Remove cover screw (No 2 in Figure 5)
Remove cover to expose terminal block (No 3 in Figure5)
Knock out circular cable entry hole leading to terminal block ( X in Figure 5)
Thread cable through back of base ( Y in Figure 5) and feed through cable knockouts ( X in Figure 5)
Mount the Transmitter and Receiver at the same height from ground level, facing each other.
Connect wires to terminal block
After alignment, lock in place top and bottom of both transmitter and receiver with rotation locking screw
(No 6 in Figure 5)
Replace front cover and fix in place with screw
Replace rubber front cover cap
7
ALIGNMENT
Figure 1
ORIENTATION
Direct sunlight can reduce the efficiency of the receiver and possible cause false alarms. In order to
prevent such alarms orientate the receiver away from the sun.
Figure 2
MULTIPLE BEAM INSTALLATIONS
In multi beam installations it is necessary to alternate the Receiver and transmitter in order to avoid
interferences.
Figure 3
8
TAMPER PROTECTION
Every unit has a tamper switch located under the covers protecting the cable terminals. If a tamper function is
required, connect the terminals marked “TAMP” on the RX unit in series with your alarm circuit (figure xxx). If a
24Hr tamper circuit is required, enable the panels dual end of line feature and terminate accordingly.
The transmitters tamper switch must be closed prior to beam alignment.
CONNECTIONS – Single set of beams
Figure 4
9
1
3
2
7
8
6
11
5
4
10
9
3a
X
Y
Figure 5
1 Rubber cap 7 End cap
2 Cover screw 8 Base
3 Cover 9 Water proof grommet A
3a Cover (rear view) 10 Spacer plate
4 Water proof membrane 11 Water proof grommet B
5 Terminal block PCB X Cable entry knockouts
6
Rotation locking screw Y Cable feed holes
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

HILLS ESHIELD E SHIELD WW R200 10BEAMS 15M (Cream Colour Only) Technical Manual

Type
Technical Manual
This manual is also suitable for

HILLS ESHIELD E SHIELD WW R200 10BEAMS 15M (Cream Colour Only) is a 10-beam active infrared multi-beam sensor designed to detect intrusions by creating a curtain of infrared beams between a transmitter and a receiver. When one or two adjacent beams are interrupted, the sensor triggers an alarm. With a selectable range of 5-15 meters for external installations and 10-30 meters for internal installations, it is suitable for protecting a variety of areas, including windows, doors, ceilings, skylights, and roller doors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI