Seal (with kit #3)the front and back between the plate and the TDR5 Hold the TDR just above the MD (Use of forklift truck is recommeded)
Mount the MD top plate to the TDR with screws #1 (former leg holes) Lead the interconnection wires through tule (#4) the top plate
Place tule (#4) for protection of wiring and through the excisting cable gland into the TDR
I J
Fixate the top plate to the MD with four bolts #2
Seal the TDR bottom innerside arround with silicone (#3)
Lower the TDR on the MD Seal both gaps between the topplate and the MD glass panes
Place and fixate the intermediate plate (#5) in the grease drawer location
with the excisting screws
K L
Connect the interconnection wires to the terminals in the TDR Remount all panels
Connect the TDR mains cable to the left terminals in the MD Place the bottom plates and grease drawer in the TDR
9124088/1406