Kozyheat SP41 Owner's manual

Category
Fireplaces
Type
Owner's manual
HUSSONG MANUFACTURING CO., INC.
INSTALLATION AND
OPERATION MANUAL
ͷ Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
ͷ Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d’installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez
www.kozyheat.com
.
DANGER
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
SP-41-LE
SP-41-MV
Models #SP-41-LE & #SP-41-MV
Direct Vent Gas Fireplaces
Hussong Mfg. Co., Inc.
SP-41-LE & SP-41-MV Report No: 19-561
Rev. 6, April 2021
Starting Serial Number: 20 93077 32
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces HOMEOWNER REFERENCE INFORMATION 3
Read this manual before installing or operating this appliance.
Please retain this owners manual for future reference.
Jim Hussong
President
Dudley Hussong
Board Chairman
Homeowner Reference Information
We recommend you record the following information:
Model Name: ____________________________________________
Serial Number: ___________________________________________
Dealership Purchased from: ________________________________
Date purchased/installed: __________________________________
Location of replace: ______________________________________
Dealer phone: ___________________________________________
Notes: ______________________________________________________________________________________________________________
____________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________
CON GRAT ULAT ION S!
We welcome you as a new own of a Kozy Heat gas feplace. Kozy Heat products e
designed with supi components and matials, and assembled by ained crasmen
who take pride in the wk. To ense you eceive a quality product, the bn and valve
assembly e 100 pcent test-fed, and the complete feplace is thoughly inspected befe
packaging. O commitment to quality and custom satisfaction has emained the same f
ov 40 yes. We o a complete line of gas, wood, and elecic feplaces, along with stylish
accessies to complement any dec. Adding a feplace is one of the best ways to increase the
value of yo home, and we e proud to o a netwk of deals throughout the couny to
help make yo expience evything you imagine. We pride oselves in being dedicated not
only to functionality and eliability, but also custom safety. We o o continual suppt
and guidance to help you achieve the maximum benet and enjoyment om yo Kozy Heat
gas feplace.
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TABLE OF CONTENTS 5
TABLE OF CONTENTS
HOMEOWNER REFERENCE INFORMATION ................................. 3
TABLE OF CONTENTS .....................................................................5
1.0 INTRODUCTION ......................................................................7
1.1 Appliance Certication ............................................................................. 7
1.2 California Proposition 65 Warning ........................................................ 7
1.3 Requirements for the Commonwealth of Massachusetts ............ 7
2.0 SPECIFICATIONS .....................................................................8
2.1 Heating Specications .............................................................................. 8
2.2 Electrical Specications ............................................................................ 8
2.3 Appliance Dimensions .............................................................................. 9
2.4 Safety Barrier Dimensions ........................................................................ 10
3.0 FRAMING .................................................................................11
3.1 Appliance Placement Considerations ................................................. 11
3.2 Floor Support and Protection ................................................................. 11
3.3 Stand-o Assembly and Installation .................................................... 12
3.4 Nailing Tabs Installation............................................................................ 12
3.5 Clearances to Combustibles ................................................................... 13
3.6 Wall Enclosure Rough Opening ............................................................. 14
3.7 Vent Termination Framing ....................................................................... 15
3.8 Outdoor Covered Fireplace Installation .............................................. 16
4.0 FACING AND FINISHING .........................................................18
4.1 Facing and Finishing Requirements ..................................................... 18
4.2 Safety Barrier Installation ......................................................................... 20
5.0 GAS LINE CONNECTION .........................................................21
5.1 Gas Conversion (sold separately) .......................................................... 21
5.2 Gas Pressures ................................................................................................ 21
5.3 Gas Line Installation ................................................................................... 21
6.0 TERMINATION LOCATIONS .................................................... 22
6.1 Vertical Vent Cap Termination ................................................................ 22
6.2 Minimum Termination Clearances ........................................................ 23
7.0 VENTING ..................................................................................24
7.1 Approved Vent Systems ............................................................................ 24
7.2 Venting Requirements .............................................................................. 24
7.3 Restrictor Assembly and Installation ................................................... 25
7.4 Vent Installation ........................................................................................... 26
7.5 Class A Chimney/Masonry Chimney Conversion ............................ 29
7.6 Coaxial to Co-Linear Chimney Conversion ........................................ 30
7.7 #700-2 Series Direct Vent Termination Kit(s) ..................................... 31
8.0 FIREPLACE SETUP ................................................................... 32
8.1 Glass Frame Assembly ............................................................................... 32
8.2 #SP41-50A Log Set Installation .............................................................. 33
8.3 Control Board Removal and Installation ............................................. 34
9.0 ELECTRICAL INFORMATION ..................................................35
9.1 Electrical Specications ............................................................................ 35
9.2 Wiring Requirements ................................................................................. 35
9.3 #SP-028 Optional Fan Kit .......................................................................... 38
10.0 OPERATING INSTRUCTIONS ................................................ 39
10.1 Lighting Instructions (#SP-41-LE) ....................................................... 39
10.2 Lighting Instructions (#SP-41-MV) .................................................... 41
11.0 ADJUSTMENT ........................................................................43
11.1 Gas Pressure Testing ................................................................................ 43
11.2 Burner Flame Adjustments ................................................................... 45
12.0 TROUBLESHOOTING.............................................................47
12.1 Electronic Ignition System ....................................................................47
12.2 Continuous Pilot Ignition (Millivolt) System ................................... 49
13.0 MAINTENANCE......................................................................51
13.1 Firebox .......................................................................................................... 51
13.2 Fan (optional) ............................................................................................. 51
13.3 Vent System ................................................................................................ 51
13.4 Glass Assembly .......................................................................................... 51
13.5 Burner and Pilot System ........................................................................ 52
14.0 REPLACEMENT PARTS LIST..................................................53
LIMITED LIFETIME WARRANTY ....................................................56
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7
1.0 INTRODUCTION
1.1 Appliance Certication
Laboratory: PFS in Cottage Grove, Wisconsin
Standards:
ANSI Z21.88-2017/CSA 2.33-2017, Vented Gas Fireplace Heaters
CSA 2.17 2017, Gas-Fired Appliances for Use at High Altitudes
This installation must conform with local codes, or in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
the Natural Gas and Propane Installation Code, CSA B149.1.
1.2 California Proposition 65 Warning
WARNING: This product can expose you to chemicals including
Carbon Monoxide, that is an externally vented by-product of fuel
combustion, which is [are] known to the State of California to cause
birth defects or other reproductive harm. For more information, visit
www.P65Warnings.ca.gov.
1.3 Requirements for the
Commonwealth of Massachusetts
The following requirements reference various Massachusetts and
national codes not contained in this manual.
For all sidewall horizontally vented gas fueled equipment installed
in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the
Commonwealth and where the side wall exhaust vent termination
is less than (7) feet above nished grade in the area of the venting,
including but not limited to decks and porches, the following
requirements shall be satised:
1.3.1 Installation of Carbon Monoxide Detectors
At time of installation of side wall horizontally vented gas fueled
equipment, the installing plumber or gas-tter shall observe that
a hard wired carbon monoxide detector with an alarm and battery
back-up is installed on the oor level where the gas equipment is
to be installed. In addition, the installing plumber or gas-tter shall
observe that a battery operated or hard wired carbon monoxide
detector is installed on each additional level of the dwelling, building
or structure served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property owner
to secure the services of qualied licensed professionals for the
installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled
equipment is installed in a crawl space or attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed
on the next adjacent oor level. In the event that the requirements
of this subdivision can not be met at the time of completion of
installation, the owner shall have a period of thirty (30) days to
comply with the above requirements; provided, however, that during
said thirty (30) day period, a battery operated carbon monoxide
detector with an alarm shall be installed.
1.3.2 Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the
above provisions shall comply with NFPA 720 and be ANSI/UL 2034
listed and IAS certied.
1.3.3 Signage
A metal or plastic identication plate shall be permanently mounted
to the exterior of the building at a minimum of eight (8) feet
above grade directly in line with the exhaust vent terminal for the
horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print no less the one-half inch (½) in size, “GAS VENT
DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
1.3.4 Inspection
The state or local gas inspector of the side wall horizontally vented
gas fueled equipment shall not approve the installation unless, upon
inspection, the inspector observes carbon monoxide detectors and
signage installed in accordance with the provisions of 248 CMR 5.08
(2) (a) 1 through 4.
1.3.5 Exemptions
The following equipment is exempt from 248 CMR 5.08 (2) (a) 1
through 4: The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition of NFPA 54 as
adopted by the Board; and Product Approved side wall horizontally
vented gas fueled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or in part for
residential purposes.
1.3.6 Manufacturer Requirements
1.3.6.1 Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizontally
vented gas equipment provides a venting system design or venting
system components with the equipment, the instructions provided
by the manufacturer for installation of the equipment and the
venting system shall include:
Detailed instructions for the installation of the venting system
design or the venting system components; and
A complete parts list for the venting system design or venting
system.
1.3.7 Gas Equipment Venting
System NOT Provided
When the manufacturer of Product Approved side wall horizontally
vented gas equipment does not provide the parts for venting the
ue gases, but identies “special venting systems, the following
requirements shall be satised by the manufacturer:
The referenced “special venting systems instructions shall
be included with the appliance or equipment installation
instructions and;
The “special venting systems” shall be Product Approved by the
Board, and the instructions for that system shall include a parts
list and detailed installation instructions.
A copy of all installation instructions for all Product Approved
side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all venting
design instructions shall remain with the appliance or equipment at
the completion of the installation.
8 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
2.0 SPECIFICATIONS
2.1 Heating Specications
Natural Gas Propane
Maximum
Input Rating
28,000 Btu/h
(8.2 kW)
28,000 Btu/h
(8.2 kW)
Minimum
Input Rating
14,000 Btu/h
(4.1 kW)
14,000 Btu/h
(4.1 kW)
Manifold Pressure
(High)
3.5” WC
(0.87 kPa)
11” WC
(2.74 kPa)
Manifold Pressure
(Low)
1.6” WC
(0.40 kPa)
6.4” WC
(1.59 kPa)
Orice Size (DMS) #41 #53
2.1.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer to
National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1 Natural
Gas and Propane Installation Code, local authorities, or codes having
jurisdiction in your area regarding derate guidelines.
2.1.1.1 US Installations
Refer to the American Gas Association guidelines for the gas designed
appliances derating method. For elevations above 2,000’ (610m),
input ratings are to be reduced by 4% for each 1,000’ (305m) above
sea level.
2.1.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500’ (1,372m),
the certied high altitude rating shall be reduced at the rate of 4% for
each additional 1,000’ (305m).
2.2 Electrical Specications
The junction box in this appliance requires 120VAC, 60Hz, and 6
Amps.
Verify the household breaker is shut o prior to working on any
electrical lines.
The AC power supply to this appliance must be hot at all times
and shall not have a switch installed in it.
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces SPECIFICATIONS 9
2.3 Appliance Dimensions
Figure 2.1, Appliance Dimensions
5¼
(133mm)
15
⁄
(390mm)
9
⁄
(237mm)
24
⁄
(611mm)
37”
(940mm)
34
⁄
(874mm)
40
¾
(1035mm)
34
½
(878mm)
15”
(380mm)
LEFT SIDE
TOP VIEW
FRONT VIEW RIGHT SIDE
GAS LINE
HOLE
ELECTRICAL
ACCESS
10 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
2.4 Safety Barrier Dimensions
WARNING: A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be installed for
the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with
Hussong Mfg.s barriers for this appliance.
IMPORTANT: Consider the height of hearth nish material when
building a replace platform. Proper installation of overlays require
the bottom of the replace to be level with nished hearth.
Please refer to Section 4.2 Safety Barrier Installation on page 20 for
installation instructions.
37⁄
(957mm)
26
⁄
(668mm)
26
⁄
(664mm)
37
⁄
(954mm)
37
⁄
(957mm)
26
⁄
(668mm)
SP41A-POL SP41-POL
SP41-ES2
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 11
3.0 FRAMING
3.1 Appliance Placement Considerations
WARNING: Due to high temperatures, the appliance should be located
out of trac and away from furniture and draperies.
FIRE HAZARD: Do NOT install this appliance directly on carpeting,
vinyl, or any other combustible material other than wood.
This appliance must be installed on a level surface capable of
supporting the replace and venting.
Determine the exact position of your replace. Consider
the hearth width, height, and depth (if applicable) for your
installation.
Please be aware of the large amount of heat this replace will
produce when determining a location.
3.2 Floor Support and Protection
Floor protection in front of the replace is not required.
Combustible material may be used if installing a hearth
extension. Consider the thickness of the hearth extension
nishing material if building a replace platform. The bottom
of the replace must be level with nished hearth extension for
proper t of an overlay (optional).
If this appliance is to be installed directly on carpeting, tile,
or other combustible material other than wood ooring, this
appliance shall be installed on a metal or wood panel extending
the full width and depth of the appliance.
If the appliance is to be installed above oor level, a solid,
continuous platform must be constructed below the appliance.
12 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
3.3 Stand-o Assembly and Installation
WARNING: The top stand-os brackets provide the required minimum
clearance to the header. The 1” (25mm) top stand-o ange
accommodates 1/2” (12mm) combustible facing material (sheetrock).
The clearance to header must be maintained.
Top stand-o brackets must be formed and attached prior to
positioning replace into framed opening.
1. Remove and save (4) screws securing the stand-o brackets on
top of the replace.
2. Form each stand-o bracket by bending at perforations, as
shown.
3. Align the holes in the formed stand-o brackets with the
holes on top of the replace. Secure with (4) screws previously
removed.
3.4 Nailing Tabs Installation
NOTE: The nailing tabs on both sides of the appliance allow installations
for a ush mount, 1/2” (13mm) facing material, or 5/8” (16mm) facing
material.
CAUTION: Never permanently remove these assemblies from the
replace—they must be secured regardless of nish material used.
1. Locate the nailing tabs on the right and left sides of the replace
necessary to accommodate the thickness of your facing material.
2. Bend out the (4) nailing tabs until parallel with replace face. Do
not bend toward replace face.
3. When installing, center the replace in the rough opening to
allow for the minimum 1/4” (6mm) clearance from the appliance
corners.
4. Secure the appliance to the framing studs by using nails or
screws through the nailing tabs.
Figure 3.1, Stand-o Assembly and Installation
STAND-OFF BRACKETS, AS SHIPPED
STAND-OFF BRACKETS INSTALLED
Flush mount
1/2” facing material
5/8” facing material
Flush mount
1/2” facing material
5/8” facing material
Figure 3.2, Nailing Tab Installation
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 13
3.5 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-os 0” 0mm
From facing material 1” (25mm) stand-o ange 0” 0mm
From appliance back stand-os 0” 0mm
From appliance corners 1/4” 6mm
From appliance front 36” 914mm
From appliance top to ceiling 25” 653mm
A 45° projection from appliance sides 0” 0mm
Appliance sides to adjacent sidewall 4-1/2” 114mm
Fireplace enclosure oor to 3/4” (19mm) trim 37-1/8” 943mm
Mantel 6” (152mm) deep from replace enclosure oor 40-1/2” 1030mm
Minimum height of replace enclosure 47-1/4” 1200mm
Minimum width of replace enclosure 41” 1040mm
Minimum depth of replace enclosure 15-1/2” 393mm
Base of the replace to ceiling 76” 1930mm
Rigid pipe venting to enclosure top for minimum horizontal terminations 5 126mm
Figure 3.3, Typical Installation Options
15½
(394mm)
½
(14mm)
41”
(1041mm)
54
½
(1384mm)
¼
(6mm)
12
⁄
(308mm)
26
⁄
(682mm)
38
½
(978mm)
15
½
(394mm)
½
(14mm)
41”
(1041mm)
41”
(1041mm)
TYPICAL VERTICAL INSTALLATION TYPICAL HORIZONTAL INSTALLATION
TYPICAL CORNER INSTALLATION
14 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
3.6 Wall Enclosure Rough Opening
WARNING: Provide adequate clearance in front of the replace for
barrier removal, component access, gas line installation, service
access, etc.
NOTE: The construction of the replace wall enclosure must comply
with local building codes and all clearances as outlined in this manual.
NOTE: Cold air transfer area. The replace wall enclosure should be
constructed in a manner to prevent cold air from entering the room
and outside walls should be insulated.
For minimum horizontal vent termination framing, see Section
3.7 Vent Termination Framing on page 15.
If masonry (optional) is to be used, prepare the foundation
necessary for the full masonry load.
If installing optional fan assembly #SP-028, it is easier to install
before unit installation. Please refer to Section 9.3 #SP-028
Optional Fan Kit on page 38.
3.6.1.1 TV Recess Construction
WARNING: All clearances to venting must be maintained.
Mounting a television above a replace has become a common
practice. Television surface temperatures are aected by mantel
depth, ceiling heights, and wall and mantel construction material.
Most television manufacturers specify in their instructions that a
television should not be installed on, near, or above a heat source.
Television location rests solely on the homeowner. It is the home
owner’s responsibility that the preferred TV mounting and mantel
design will not exceed the listed maximum operation temperature of
their electronic goods.
Tests performed determined that surface temperatures did not exceed
150°F (66°C) when a 4¼” (108mm) deep recess is constructed above the
replace. See illustration below.
Figure 3.4, Framing Dimensions
4½
(114mm)
47
¼
(1200mm)
37”
(940mm)
41”
(1044mm)
15
½
(393mm)
76”
(1930mm)
37”
(940mm)
41”
(1040mm)
15
½
(394mm)
TV Recess
Construction
Ceiling
Single vertical header board
required to maintain clearances
to combustibles
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 15
3.7 Vent Termination Framing
3.7.1 Vent Termination Framing Requirements
This is a cold air transfer area. The replace enclosure must comply
with all clearances as outlined in this manual, and be constructed
in compliance with local building codes. Outside walls should be
insulated to prevent cold air from entering room.
Exterior vent termination location must be in compliance with
Section 6.2 Minimum Termination Clearances on page 23.
IMPORTANT - METAL FAB VENT SYSTEM: When installing Metal Fab
vent pipe, adapter #4DDA must be used o the top of the appliance.
This will increase the minimum height for the center of the vent pipe
by 3-3/4” (95mm) when framing the wall pass through.
3.7.1.1 Clearances
A minimum of 1” (25mm) clearance on all sides of the vertical
vent pipe must be maintained.
A minimum of 1” (25mm) clearance from the top surface on the
horizontal pipe must be maintained.
A minimum of 1” (25mm) clearance on the sides and bottom
surfaces on the horizontal pipe must be maintained.
A minimum of 5” (1279mm) clearance from rigid venting to
the enclosure top is required in minimum horizontal vent
termination installations. The horizontal pipe after the wall pass-
through must maintain a 1” (25mm) clearance to combustibles
on all surfaces of the pipe.
3.7.2 Vertical Terminations
Follow vent pipe manufacturer’s installation instructions for
vertical terminations.
Attic insulation shields may be insulated using unfaced
insulation products listed as non-combustible per ASTM E 136.
3.7.3 Horizontal Terminations
WARNING: Do not recess the vent cap into wall or siding.
IMPORTANT: Horizontal vent sections require 1/4” (6mm) rise for every
12” (305mm) of travel.
Kozy Heats #700-WPT, or wall thimble products that comply with the
required 1” (25mm) top clearance to combustibles, must be installed
for all horizontal vent runs that pass through interior or exterior walls.
#700-WPT has a wall thickness of 4” (101mm) to 6-1/2” (165mm).
These wall thimble products may be insulated using unfaced
insulation products listed as noncombustible per ASTM E 136.
Elbows listed with approved vent systems for this appliance vary in
vertical length. Please consult the vent manufacturer’s instructions to
determine the elbow dimension used for installation. Adjust the wall
pass-through rough opening dimensions as necessary to maintain
clearance requirements.
3.7.3.1 Wall Pass Through Information and Framing
Rigid pipe dimensions are tested with listed Simpson Duravent
pipe. Other manufacturers product dimensions may vary.
Flexible pipe framing dimensions are tested with Kozy Heat
#700-2 Series Flexible Vent System. See Figure 3.5.
1. Measure from oor level of the replace to the center of where
the vent pipe will penetrate the wall.
2. Cut and frame an opening in the wall to allow the vent system to
run level through the wall pass-through.
3. Follow the vent pipe manufacturer’s installation instructions for
vent installation.
38¾
(985mm)
15
½
(393mm)
45
⁄
(1158mm)
15
½
(393mm)
Minimum Horizontal Termination
Natural Gas and Propane
Minimum Horizontal #700-2 venting
Natural Gas and Propane
700-WPT Framing Dimensions
Ships with #700-2
9½
(241mm)
4
¾ (120mm)
9
½
(241mm)
Figure 3.5, Minimum Horizontal Venting Framing
16 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
A
B
CC
The overhang (A) must be a minimum of 1/2 or
greater of the rooine elevation (B) above the base
of the replace.
The width of the overhang to each side of the
appliance (C) must be a minimum of 1/2 or
greater of the rooine elevation (B) above the
base of the replace.
EXAMPLE: If rooine (B) is 10’ above the base of replace, the overhang (A) must be 5’
or greater. The width of the overhang to EACH side of the replace (C) must be 5’ or greater.
SIDE OF
FIREPLACE
BACK OF
FIREPLACE
FRONT OF
FIREPLACE
ROOF OVERHANG
Figure 3.6, Outdoor Covered Fireplace Install - 1
3.8 Outdoor Covered Fireplace Installation
A outdoor covered replace installation allows a replace to be
installed in an outdoor covered area, where the appliance is protected
from direct precipitation.
Follow the instructions and illustrations in this section for installation
procedures.
3.8.1 Safety Screen Barriers
Hussong Mfg. highly recommends to use black painted safety barriers
in outdoor installations. Other screen barriers that incorporate
a plated or patina nish are highly susceptible to oxidation and
discoloration.
3.8.2 Requirements
The continuous insulated building envelope and weatherproof
membrane are not to be interrupted by replace installation. See
Figure 3.8 on the following page.
Fireplace operation is approved from 40°F to 110°F.
All wiring connections shall be in accordance with outdoor
requirements of NECA NFPA 70.
All clearances and requirements in your appliance manual must
be adhered to.
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 17
Continuous insulated building
envelope and weatherproof
membrane are not interrupted by
replace installation
Minimum weatherproof
overhang in front and sides
Minimum weatherproof
overhang in front and sides
Minimum weatherproof
overhang in front and sides
Minimum weatherproof
overhang in front and sides
Free standing structure
(weatherproof enclosure)
INSIDE
OUTSIDE
INSIDE
Figure 3.7, Outdoor Covered Fireplace Install - 2
18 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
4.0 FACING AND FINISHING
4.1 Facing and Finishing Requirements
4.1.1 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be
maintained.
Combustible Mantel Projections: As referenced in Figure 4.1, the
3/4” (19mm) trim can start at 37-1/8” (943mm) above the replace
enclosure oor with a 6” (152mm) mantel starting at 40-1/2”
(1030mm) above the replace enclosure oor. Mantel projections can
increase 1” (25mm) of depth for every 1” (25mm) of height starting at
the 6” (152mm) mantel.
Non-combustible Mantel Projections: A minimum vertical clearance
of 6” (152mm) above the appliance to a maximum 6” (152mm) depth
of a non-combustible mantel. Follow projection 1” (25mm) up for
every 1” (25mm) deeper.
4.1.2 Adjacent Sidewall Requirements
The adjacent sidewall must be 4-1/2” (114mm) from the
appliance sides.
4.1.3 Finishing Recommendations
NOTE: The surface area above the appliance may be aected by high
temperatures emitted from this appliance. To help avoid or reduce the
possibility of the sheetrock to crack, Hussong Mfg. recommends the
following methods:
Ensure the non-combustible material and sheetrock is dry and
dust free.
For taping and mudding seams, we recommend heat resilient
tape, mesh and joint compounds, such as Durabond. Mud must
be cured as per manufacturer’s recommendations.
For a painted surface, use a high quality acrylic latex primer
and nish coat. Avoid at or light-colored paints to prevent
discoloring.
#SP-41 LE & MV R.6 April 2021 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 19
Figure 4.1, Clearances to Combustibles
1”
(25mm)
4
½
(114mm)
13
⁄
(348mm)
6”
(152mm)
40
½
(1030mm)
¾ TRIM
(19mm)
37
⁄
(943mm)
15
½
(393mm)
38
¾
(985mm)
47
¼
(1200mm)
45
⁄
(1158mm)
16
⁄
(416mm)
1”
(25mm)
6”
(152mm)
40
½
(1030mm)
¾ TRIM
(19mm)
37
⁄
(943mm)
15
½
(393mm)
4
½
(114mm)
5”
(126mm)
Clearances to combustibles - rigid pipe Clearances to combustibles - ex pipe
20 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #SP-41 LE & MV R.6 April 2021
4.2 Safety Barrier Installation
4.2.1 Safety Barrier Screen (#SP41-SCR)
1. Locate the (4) slots located on each side of the replace frame.
2. Align the notched tabs located on the back of the safety screen
with the slots on the replace frame.
3. Raise the safety screen front slightly into slots and allow the tabs
to lower into position.
To remove safety screen: lift the screen up and out of slots.
4.2.2 Overlay Designs (#SP41-POL & #SP41A-POL)
1. If installed, remove the safety barrier screen.
2. Center the overlay over the safety screen.
3. Locate the (4) tabs on the overlay. Hand bend tabs to secure the
overlay to the safety screen front.
4. Locate the (4) slots located on each side of the replace frame.
5. Align the notched tabs located on the back of the safety screen
with the slots on the replace frame.
6. Raise the safety barrier slightly into slots and allow the tabs to
lower into position.
To remove safety barrier and overlay: lift the screen up and out
of slots.
Figure 4.2, Safety Barrier Screen Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57

Kozyheat SP41 Owner's manual

Category
Fireplaces
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI