Operating Instructions / Version 2.0
SCD110 Operating Instructions v2.0 2 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
Table of Contents
1 About the Operating Instructions 5
1.1 Definition of Special Notices ................................................................................................ 5
1.2 Definition of General Notices ............................................................................................... 5
2 Safety and Intended Use 5
2.1 Intended Use ........................................................................................................................ 6
2.2 Disposal ................................................................................................................................ 6
3 Introduction 6
3.1 Scope of Delivery ................................................................................................................. 6
4 Technical Specification 7
4.1 Housing ................................................................................................................................ 7
4.2 Dimensions ........................................................................................................................... 7
4.3 Device Specifications ........................................................................................................... 8
4.4 Operating Conditions ........................................................................................................... 8
4.5 Sensors ................................................................................................................................ 8
4.6 Measurement Range and Accuracies .................................................................................. 8
4.7 Resolution ............................................................................................................................ 8
4.8 Communication .................................................................................................................... 9
4.9 User Interface ....................................................................................................................... 9
4.10 Communication Interfaces ................................................................................................... 9
SCD110 Operating Instructions v2.0 3 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5 Installation and Start to Use 10
5.1 Mounting the SCD .............................................................................................................. 10
5.2 Connecting to the SCD ...................................................................................................... 10
5.3 SCD App Tabs .................................................................................................................... 12
5.4 Configuring the SCD .......................................................................................................... 13
5.5 Threshold Setting ............................................................................................................... 14
5.6 Streaming ........................................................................................................................... 14
5.7 Data on the Chart ............................................................................................................... 15
5.7.1 Chart View Options 16
5.8 Logging and Transferring the Data .................................................................................... 17
5.9 Removing the SCD ............................................................................................................ 19
5.10 Reusing the SCD ............................................................................................................... 19
6 General Operating Modes of SCD 20
6.1 General Behavior ............................................................................................................... 20
6.2 Resetting the SCD ............................................................................................................. 20
6.3 Streaming via Bluetooth Low Energy (BLE) ....................................................................... 20
6.4 Logging Data into the Local Memory ................................................................................. 20
6.4.1 Log File Format 21
6.5 Event Detection Mode ........................................................................................................ 22
7 Maintenance 22
8 Further Product Related Information 23
9 Trouble Shooting 23
SCD110 Operating Instructions v2.0 4 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
10 Regulatory and Legal Information 24
10.1 Target Markets.................................................................................................................... 24
10.2 European Union Notices .................................................................................................... 24
10.3 USA: FCC Notices ............................................................................................................. 25
10.4 Canada: ISED Notices ....................................................................................................... 25
10.5 IMDA Singapore Notices .................................................................................................... 25
10.6 ACMA Australia Notices ..................................................................................................... 25
10.7 Japan Notice ...................................................................................................................... 26
10.8 South Africa Notice ............................................................................................................. 26
10.9 Other Country Certifications ............................................................................................... 26
10.10 Bluetooth®..................................................................................................................... 26
10.11 Disposal ......................................................................................................................... 26
10.12 Restrictions of Use ........................................................................................................ 26
10.13 Open Source License Condition ................................................................................... 27
SCD110 Operating Instructions v2.0 5 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
1 About the Operating Instructions
This document presents the SCD110 operating instructions, detailed SCD110 sensor characteristics,
communication and management features over the Bluetooth interface.
This document refers to SCD110 firmware version 1.3.0.
Please ensure that your SCD110 device is working correctly by reading these instructions before
using it in your applications.
Please visit the device webpage for more information: https://www.bosch-
connectivity.com/products/sense-connect-detect
1.1 Definition of Special Notices
Warning
Indicates a hazard that could lead to minor or moderate injuries.
Always follow these instructions.
Note
Points of emphasis and reminders of device-specific operational features that could affect
the performance.
Always follow these instructions.
1.2 Definition of General Notices
2 Safety and Intended Use
Warning: Do not open the housing!
Opening the housing without authorization will void any warranty and involves risk of injury
to the user. Using the SCD according to its intended use and functions does not require
opening of the housing.
Warning: Damaged housing!
Liquid which enters the device can cause short circuits and damage the device.
This could cause fire, data loss and incorrect measurements.
Warning: Lithium battery!
The device contains a lithium battery that shall not be replaced by the user.
Read and follow the valid transportation regulations for Li batteries in case of air transport
INFO: General information and instructions that must be followed
Tip: Practical advice
SCD110 Operating Instructions v2.0 6 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
2.1 Intended Use
The SCD110 is designed for monitoring purposes and is not certified as a device to ensure functional
safety. The SCD is intended for the following application areas:
Environments
Please consider following operating conditions for the SCD110 device.
Operating temperature range
-20 °C … +85 °C
Recommended storage temperature
+10 °C … +30 °C
Humidity range
0% RH … 100% RH
Validation and testing of any use or operation which requires specific requirements and/or standards
that not explicitly mentioned in this document is the customer's responsibility.
Warning: Restricted use!
The SCD shall not be used as an element of control and safety in machines or applications
under the scope of the Machinery Directive 2006/42/EC or other functional safety
regulation. Any incident on health to people and on environment can lead to liability and
criminal prosecution of the user.
Please see also the section 10.12 Restrictions of Use.
2.2 Disposal
Disposing of this product correctly will help save valuable resources and prevent any potential
negative effects to human health and the environment, which could otherwise arise from inappropriate
waste handling. Please contact a certified recycling company or the responsible local authority for
further details on your nearest designated collection point. Penalties may apply for incorrect disposal
of this waste, in accordance with your national legislation. For further information, please refer to the
section 10.11 Disposal.
3 Introduction
The SCD is a multi-sensor IoT device that measures acceleration, magnetic fields, temperature and
light. The robust housing, compact design and easy installation make it perfectly suitable for industrial
retrofit applications, such as condition monitoring and predictive maintenance. Configuring the device
enables the user to address a broad variety of use cases.
3.1 Scope of Delivery
The SCD110 will be delivered with the following combination. The devices are ready to use.
SCD110 device with built-in battery
Quick Start Guide
Packaging unit consists of 10 devices
SCD110 Operating Instructions v2.0 7 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
Note
Please don’t cover the SCD with additional labels or stickers. Otherwise, the function of the light
sensor cannot be guaranteed.
4 Technical Specification
4.1 Housing
The SCD is built from a robust housing suited for industrial use with a self-adhesive back.
The compact design of the SCD fits perfectly in different industrial applications and enables easy, user-friendly
mounting in difficult-to-access environments.
For mounting instructions, please refer to 5.1 Mounting the SCD.
4.2 Dimensions
On button
Green/Red LED
Screw holes
1
2
2
1
3
3
SCD110 Operating Instructions v2.0 8 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
4.3 Device Specifications
4.4 Operating Conditions
4.5 Sensors
INERTIAL SENSORS
ENVIRONMENTAL SENSORS
Accelerometer (3-axis)
Temperature
Magnetometer (3-axis)
Light
4.6 Measurement Range and Accuracies
Note
Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110
might deviate from sensor specifications, depending on installation conditions and environmental
influences.
4.7 Resolution
ATTRIBUTE
VALUE
Dimension
Length 70.9 mm x Width 62 mm x Height 11.3 mm
Weight
21 g
Power supply
non-rechargeable CR2450 3V Li/MnO
2
, 490 mAh
Battery Life
up to 2 years depending on configuration and use
Enclosure protection class
IP 67
Electrical protection class
III
Sampling rates (Hz)
Acceleration : 400, 800, 1600, 3200, 6400
Magnetometer : 10
Temperature: 0.05
Light: 1.25, 10
Memory capacity
1 MB
BLE (Bluetooth Low Energy) Activation
In Standby: On push button
During operation: Automatic activation every 3 hours
Target markets and country certifications
See 10.1Target Markets
Environmental certifications
RoHS, REACH
ATTRIBUTE
RANGE
Environments
Residential, commercial, light-industrial, and industrial
Operating temperature range
-20 °C … +85 °C
Recommended storage temperature
+10 °C … +30 °C
Humidity range
0% rH … 100% rH
SENSOR
MEASUREMENT RANGE
ACCURACY
Acceleration
± 200 g
± 10%
Magnetometer
± 1300 µT (X, Y-Axis); ± 2500 µT (Z-
Axis)
± 5%
Temperature
-20 °C … + 85 °C
± 0.25 °C
Light
0 … 188000 Lux
± 15%
SENSOR
RESOLUTION
UNIT
Acceleration
0.1
g
Magnetometer
10
µT
Temperature
0.1
°C
Light
1
lux
SCD110 Operating Instructions v2.0 9 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
4.8 Communication
4.9 User Interface
4.10 Communication Interfaces
SCD has a Bluetooth Low Energy (BLE) communication interface. The BLE Communication Protocol of SCD is
available in the website to download. With this document SCD can be integrated into any gateway.
BLE
Bluetooth Low Energy V4.2 is currently supported. The SCD always acts as a peripheral device to which
other BLE devices like smartphones, tablets, gateways etc. can establish a connection.
The BLE interface is used, e.g. by a gateway or a mobile app, to:
Configure the SCD.
Transfer data.
ATTRIBUTE
VALUE
Communication
Bluetooth Low Energy
BLE 4.2
Range
up to 40 m (dependent on external influences)
ATTRIBUTE
VALUE
SCD Sensor App
Free smartphone app for configuration, read-out and
visualization. Available for Android and IOS.
SCD110 Operating Instructions v2.0 10 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5 Installation and Start to Use
5.1 Mounting the SCD
The SCD housing has a self-adhesive back for mounting.
To stick SCD on a surface, the surface must be
flat
dry
clean
Mounting the SCD:
Peel off the protective film.
Stick SCD to the surface.
5.2 Connecting to the SCD
Download the SCD Sensor App. The App is available for free in the Apple App Store or Google Play
Store. Please search for “Bosch SCDor use the QR-Codes below.
Apple App Store
Google Play Store
Activate Bluetooth on your smartphone.
To activate the SCD, press shortly the button on the device.
Start the SCD Sensor App.
TIP: The SCD can also be attached to the surface of an equipment by using screws.
SCD110 Operating Instructions v2.0 11 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
After you start the app, the help screens offer you a short overview of the most important functions. Please
have a look.
After starting, the app shows a search button. Click on the search button to find devices.
TIP: In order to select the right SCD when multiple are available, move your smartphone/tablet close to the
desired SCD.
SCD110 Operating Instructions v2.0 12 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
Choose your SCD by tapping on your device in the list of devices to establish the connection
between the SCD device and the smartphone / tablet.
5.3 SCD App Tabs
The App has different pages shown in the screenshot below.
a. Help: See help screens related to the area you are currently in.
b. Disconnect: Click on the Disconnect icon if you want to disconnect your device.
c. Settings: Rename your device and configure thresholds of the sensors.
d. View: Start / stop data streaming. See current values from the sensors.
e. Diagram: Show the streamed data in graphics.
f. Logging: Configure logging sampling rates, start / stop logging, download logging data.
a
d
b
c
e
f
SCD110 Operating Instructions v2.0 13 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5.4 Configuring the SCD
Tap on the Settings icon.
To ensure easy identification of your devices, please rename your SCD by tapping on the pencil and
typing in your preferred name. Then tap Rename.
Note
Only certain characters can be used for the device name.
The following characters are allowed: [A-Z][a-z][0-9][@.,;/\|+-*_]
SCD110 Operating Instructions v2.0 14 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5.5 Threshold Setting
The thresholds are used for threshold monitoring in SCD. When the thresholds are violated, SCD sends an
alarm via BLE. In this case the app shows the measurement values in red color. Event before the App connects
the SCD, the threshold violations can be seen in connect/scan page with a red device icon.
Set the threshold values by tapping the Settings icon.
5.6 Streaming
The function transmits sensor values to the app at a fixed rate. Values can be visualized and
recorded in the View tab. To start streaming, enable the streaming button as shown in the screenshot below.
Tap on the streaming button to start data streaming. The data is shown under the respective sensor
icon.
In case of threshold violation the values are shown in red color. This can be resetted with the “reset
thresholdsbutton.
The Accelerometer values are shown as mean (average of ~170 values) and variance (how much it
differs from the average)
SCD110 Operating Instructions v2.0 15 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5.7 Data on the Chart
Tap on the Diagram icon.
Select the sensors you want to see in the chart by tapping the sensor icons. The graphics and values
are then displayed.
TIP: In case of threshold violation, the measurement values are shown in red.
SCD110 Operating Instructions v2.0 16 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5.7.1 Chart View Options
a. Refresh: If the user zooms in on the chart, tap on this icon to restore the original view.
b. Enable/disable scrolling in the visible window to show all X values in the graph.
c. Enable/disable auto scale of the y axis of the graph.
d. Start / stop: Tap on this button to show / freeze streaming data in the graph.
e. Starts / stops recording the streaming graph.
f. Share the CSV of the last recorded session.
Note
Please attention! The data that you are recording in Diagram view is not the raw-data coming from
the sensors. It is the data shown in the graphics. For example Accelerometer values are aggregated to
mean and variance values. If you need the data for data analysis, please use Logging page to log and
download raw-data. The raw-data is more suitable to detect all details in data analysis.
a
b
c
d
e
f
SCD110 Operating Instructions v2.0 17 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
5.8 Logging and Transferring the Data
The function stores raw data in the SCD internal memory. Data can be transmitted to the smartphone
via SCD app or to the gateway over the BLE.
The logging settings can be configured by tapping on the Logging icon.
Set the desired sampling rates for each sensor which should be used by data logging.
Leave the sensors “Disabled”, if you don’t want to get data from them in the log file.
Tap on "Start logging".
SCD110 Operating Instructions v2.0 18 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
Confirm the logging start
The data is stored locally in SCD until the memory is full or until the logging is stopped by the user.
The data is ready to download.
SCD110 Operating Instructions v2.0 19 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
Note
The downloading process may take several minutes. Logging must be stopped in order to proceed
with the download.
Note
Please note that SCD can log only one axis (z-axis) in 6.4 kHz sampling rate. Logging 3-axis in this
speed is not possible. With all the other sampling rate options 3-axis data is saved.
Note
Please use the raw-data from the logging function in the data analysis. This data is recorded directly in
the embedded device (SCD), and transferred later. In this way, it is possible to save the data in high
sampling rates. Please don’t use the recorded data in Diagram view which is aggregated to reduce the
data volume in streaming.
5.9 Removing the SCD
5.10 Reusing the SCD
After the SCD has been removed, it can be reused. For mounting, proceed as described in 5.1 Mounting the
SCD. Please note that after removal the IP67 certification is no longer guaranteed.
INFO: IP67 certification can no longer be guaranteed after removal.
INFO: Do not use any sharp objects to remove the SCD.
TIP: The machine temperature should be below 40 °C.
Run a flat tool without a
sharp edge between the
SCD and the surface.
Carefully lift the SCD and
release it from the machine
surface.
SCD110 Operating Instructions v2.0 20 | 27
Data subject not change without notice | Printed in Germany | September 20 | Version 1.0
BCDS/GM
6 General Operating Modes of SCD
The operation modes are described in this chapter. For information about how to configure the SCD or how to
retrieve data from it, please refer to chapter 5 Installation and Start to Use.
6.1 General Behavior
The user can activate/deactivate each sensor in SCD to get data. Additionally, for logging the data, user can
specify different sampling rates for each sensor. On the other hand, SCD uses an optimal (fixed) sampling rate
to stream the data to the app to be visualized.
6.2 Resetting the SCD
If there are problems with the SCD, a restart of the SCD may be necessary.
In order to reset the SCD, please do the following steps:
Press the button on the SCD for at least 10 seconds.
When the button released after 10 seconds, the LED shows a short red light.
6.3 Streaming via Bluetooth Low Energy (BLE)
SCD is a Bluetooth Low Energy (BLE) device. This means that another BLE device may detect the SCD when
scanning for devices and is able to initiate a connection. By using BLE, it is possible to configure the SCD and
continuously receive measurement data. The data can be visualized in the app or consumed in a gateway. If the
user wants to integrate the SCD into his/her gateway, the required document e.g. the SCD BLE Communication
Protocol is publicly available in the website to download.
6.4 Logging Data into the Local Memory
SCD can be configured to log raw-data into its local memory. This data can be downloaded afterwards by the
smartphone app or by a gateway. Logging into the local memory is the right way to get accurate raw-data for
data analysis. SCD is able to log data in the memory, and at the same time, stream the data via BLE.
When the user starts logging in the app, the SCD continues to log data until the local memory is full or logging is
stopped by the user. The time until the memory is full depends on the SCD settings. Please see below some
examples.
Examples:
Accelerometer @6.4kHz (1 axis) will fill the memory in 60 seconds
Accelerometer @3.2kHz (3 axis) will fill the memory in 40 seconds
Accelerometer @1.6 kHz (3 axis) will fill the memory in 80 seconds
Temperature alone will fill the memory in 21 days
INFO: All stored values are lost in this process. Only the name of the SCD stays unchanged.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Bosch SCD 110 Operating Instructions Manual

Category
Measuring, testing & control
Type
Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI