MTI Instruments Accumeasure Digital Series Quick start guide

  • Hello! I'm your chat assistant, and I've reviewed the Quick Start Guide for the Accumeasure D series. This guide covers the initial setup of your device, including probe and connection, software installation, and how to power up the device. I can assist you with questions regarding connecting the probe, installing the necessary software, and understanding the various connection options like USB and Ethernet.
  • What is the recommended connector torque pressure?
    How do I connect the Digital Accumeasure to my PC?
    How to switch communication to Ethernet?
target ground
equipment ground
24
VDC
L N
series Quick Start Guide
7001-0090 Rev 1.0
Recommended connector torque pressure:
3 to 5 lbf-in (0.3 to 0.6 Nm)
turn
Use the two wrenches provided one to hold it steady
and one for turning
hold steady
Connecting Probe to Amplifier
hold steadyhold steadyhold steady
turnturnturn
Connect your probe: match the serial number etched on the probe and the serial number indicated on the
sticker found at the back of the amplifier and connect them to the corresponding
channels specified.
serial number
serial number
1
2Connect wires and cables:
ANALOG ANALOG
OUTPUTOUTPUT
ANALOG
OUTPUT
DIGITALDIGITAL
OUTPUTOUTPUT
DIGITAL
OUTPUT
differential output
single-ended output
CH1CH2
+
-
+
-
3Install Software
FRun SETUP.exe
FFollow setup guide
4Power-up the Digital Accumeasure
FConnect the Digital Accumeasure (micro USB) to your PC (USB-A)
FNew Hardware Detected will display on your screen
FIf Windows cannot find driver, go to
Windows XP: Control Panel>System> Device Manager
Windows 7: Control Panel> Hardware and Sound> Device
Manager
FUnder Other devices, right click Digital Accumeasure >update
driver...
FWindows XP: No, not this time> Install from a list or specific
location>Don't search> Show All Devices > Have Disk...
Windows 7: Browse my computer for driver software
FGo to C:\Digital Accumeasure\USB driver\
FInstall
*Analog Output not
available in all models.
Run Digital Accumeasure
Support Program
5
series Quick Start Guide
Start Digital Accumeasure Support
Program
FClick Scan for Units
FClick Connect
7001-0090 Rev 1.0
Fif you are using USB, you are now
setup to acquire data.
Fto switch to Ethernet connection
please proceed to the following steps.
Using Ethernet connection (make sure the USB
cable is still connected)
6
Default communication is via USB. To switch
to Ethernet, go to User Settings tab >
Communications > Mode Choose Ethernet
Confirm the
default
configurations are
as shown.
Connect the Digital Accumeasure to your PC via RJ45
Ethernet Cable
FClick start or button
FGo to Control Panel
For Windows 7 or 8
F Under Network and Internet
F Click Network and Sharing Center
FClick Local Area Connection
FClick Properties
FChoose Internet Protocol Version 4
(TCP/IPv4)
7
For Windows XP
FUnder Network Connections
FRight Click Local Area Connection
FClick Use the following IP address:
Network Credentials
IP address:
Subnet mask:
Default Gateway:
192 . 168 . 168 . 249
255 . 255 . 255 . 0
255 . 255 . 255 . 0
FClick Properties
FChoose Internet Protocol (TCP/IP)
FClick Properties
FGo back to Digital Accumeasure Support
Program
FClick Scan for Units. You should now see the
network connected Digital Accumeasure
FClick Connect
FIf not, you may need to reboot your PC after setup
FMake sure to SAVE your changes.
FPower off/Unplug Power from
the Digital Accumeasure.
FPower up/Plug in the Digital
Accumeasure.
FThe LED indicator will show
the communication has been
switched to Ethernet.
/