Contec CNT-3204IN-USB Owner's manual

Type
Owner's manual
Setu
p
Guid
e
CONTEC CO.
,
LTD.
3-9-31
,
Himesato
,
Nishi
y
odo
g
awa-ku
,
Osaka 555-0025
,
Ja
p
an
https://www.contec.com
/
No part of this document may be copied or reproduced in any form by any means
without prior written consent of CONTEC CO., LTD.
NA06355 (LYWF271) [04052019] April 2019 Edition
Isolated 32-bit
Up/Down Counter Unit
CNT-3204IN-USB
Thank you for purchasing this product. The product you have purchased consists of the
following items.
Check, with the following list, that your package is complete.
If you find any item either missing or damaged, please contact the sales representative you
purchased the product from.
Before actual use, read the Reference Manual which can be viewed on the CONTEC website
to use this product correctly.
The following manuals and driver software come with this product. Visit the CONTEC website
and download them before using the product.
The name of the documents Contents How to
g
et
Setup Guide (This document) The outline of the product. Included in the package
(Printed matter)
Reference Manual Product settings and operation check-
in
g
are described.
Download(PDF)
The name of the documents Contents How to
g
et
Highly functional driver
API-CNT(WDM) for USB
Driver software of counter input Download
(ZIP)
Download
https://www.contec.com/download/
Reference for installation
Information Reference to
Installation on Windows Refer to this guide or the
ile API-CNT(WDM) for USB driver help
\
HELP
\
ENG
\
APIUSBP.chm.
1. About the Product
This product is a USB 2.0 supporting counter unit, which adds the function of counting
pulse signals input from external devices through a USB port to a PC.
It has four channels of 32-bit up/down counters, allowing external devices such as a rotary
encoder and a linear scale to be connected. Input interface of pulse signal is opto-coupler
isolated input.
Compact design, (188.0(W)×78.0(D)×30.5(H)mm), features flexibility in installation. The
product can be set on the floor, wall, and inside the console or equipment with the DIN rail.
2. Product Configuration
Check, with the following list, that your package is complete.
Product
[CNT-3204IN-USB]
...1
8-pin Connecto
r
...4 4-pin
Connecto
r
...1
USB Cable (1.8m)...1 USB Cable
Attachment...1
Rubber Feet...4 AC Adapter...1 AC Cable...1 Serial Number
Label...1
Setup Guide...1
(This document)
Warrant
y
Certificate...1
3. Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
DANGER
Do not use the product in locations exposed to a flammable or corrosive gas. It may
cause explosion, fire, electrical shock, or malfunction.
CAUTION
This product contains precision electronic elements and must not be used in locations
subject to physical shock or strong vibration. Otherwise, the product may malfunction,
overheat, or cause a failure.
It may cause a trouble in recognizing and operating the device according to the kind of
USB hub.
Do not use or store this product in high temperature or low temperature surroundings,
or do not expose it to extreme temperature changes. Otherwise, the product may mal-
function, overheat, or cause a failure.
Do not use or store this device where it is exposed to direct sunlight or near stoves or
other sources of heat. Otherwise, the product may malfunction, overheat, or cause a fail-
ure.
Do not use the product in the vicinity of devices that generate strong magnetic force or
noise. Otherwise, the product may malfunction, overheat, or cause a failure.
Do not touch this product's metal plated units (USB connector) with your hand.
Otherwise, the unit may malfunction, overheat, or cause a failure. When you touch the
product, wipe it clean with industrial alcohol.
Do not close the ventilation hole(s) of this product by, for example, placing an object.
This may cause overheating, malfunction, and/or failure of the product.
Do not touch this product's power connector or interface connector with your hand.
Otherwise, the product may malfunction, overheat, or cause a failure due to static
electricity.
Do not set or remove the power connector and the internet connector when the power
is on. This may cause a failure.
Do not plug or unplug the 12-24VDC power with the product while the 12-24VDC is
outputting the voltage. This may cause a failure.
Do not operate switches when the power is on. This may cause a failure.
When connecting multiple products, set one product at a time. Complete the setup
before starting to connect the next product.
The specifications of the product are subject to change without notice for enhancement
and quality improvement. Even when using the product continuously, be sure to read the
manual in the CONTEC's website and understand the contents.
Do not modify the product. CONTEC will bear no responsibility for any problems, etc.,
resulting from modifying the product.
The product must always be accompanied with this Setup Guide.
When disposing of the product, follow the disposal procedures stipulated under the rel-
evant laws and municipal ordinances.
Regardless of the foregoing statements, CONTEC is not liable for any damages whatso-
ever (Including damages for loss of business profits) arising out of the use or inability to
use this CONTEC product or the information contained herein.
Usage limitation
This product has not been developed or manufactured to be used in systems including the
equipment which is directly related to human lives *1 or the equipment which involves hu-
man safety and may significantly affect the maintenance of public functions *2. Therefore,
do not use the product for such purposes. Use outside The U.S. may conflict with radio laws
and regulations of the country concerned. Please do not use outside The U.S.
*1 Medical devices such as life-support equipment and devices used in an operating the-
ater.
*2 Main control systems at nuclear power stations, safety maintenance systems at nuclear
facilities, other important safety-related systems, operation control systems within
group transport systems, air-traffic control systems, etc.
4. Option
AC-DC Power Adaptor (12VDC, 1A): POA201-10-2 *1
Magnet (Four Piece Set): CPS-MAG01-4
DIN rail fitting power supply
15W(Output: 12VDC 1.3 A): CPS-PWD-15AW12-01 *2,
30W(Output: 24VDC 1.3 A): CPS-PWD-30AW24-01 *2 ,
90W(Output: 24VDC 3.8 A): CPS-PWD-90AW24-01 *2
*1 The specification of the operating ambient temperature is 0 to 40 °C. It is the same
adapter included in this package.
*2 The specification of the operating ambient temperature is -20 to 70 °C.
*Visit the CONTEC website to check the details.
5. Product Nomenclature and
Function
Nomenclature of Product Components
Number Name Number Name
1 Interface connector (8-pin) 5 USB port [mini-B]
2 Input resistance settin
g
switch 6 Power suppl
y
connector
3 LED indicator 7 Interface connector(4-pin)
4 Settin
g
switch 8 Pull-up settin
g
switch
Setting Switch
There are two setting switches. “x16” and “x1” represent high bits and low bits of Module
ID respectively.
Factory settings “00” can be used when only one device per model is connected to one
computer. Each device should be assigned a unique Module ID in the range of 00 - 7Fh
when several devices with the same model are being connected.
Module ID
(x16)
[0]
Module ID Setting description
00 - 7Fh It is a setting range for module IDs.
Module ID
(x1)
[0]
FFh Use only when upgrading the firmware.
Module ID 00h (Factory settings)
LED Indicator
LED name LED color Status Description
POWER Green
OFF : Power-OFF
ON : Power-ON
Display power status
A, B, DI Yellow
OFF : Input-OFF
ON : Input-ON
Input status
Z Yellow
P
ositive logic OFF : Input-ON
ON : Input-OFF
Negative logic OFF : Input-OFF
ON : Input-ON
Input status
Power Supply Connector
Use the supplied AC adapter to supply power.
Attached connector: European type
terminal 3.5mm pitch 3-pin
j
ack connecto
r
Mark Description
Frame ground
Vi- Power supply (GND)
Vi+ Power supply (12 – 24VDC±10%)
Interface Connector
CNT0 ~ 3
Signal
name
Function
PCOM
Plus common of input signal
Connect the positive side of external power suppl
y
A Phase-A input
B Phase-B input
Z Phase-Z input
DI General-purpose input
EQ.P
Plus common of equal output
Connect the positive side of external power suppl
y
EQ Count equal output/General-purpose output
EQ.N
Negative common of equal output
Connect the ne
g
ative side of external power suppl
y
Support cable:
AWG28-16(Cable length should satisfy the power specification including the cable voltage
drop)
EXT CTRL
Signal
name
Function
GND Ground of external sampling start/stop/clock signal
CLK External sampling clock signal
STOP External sampling stop signal
START External sampling start signal
Support cable:
AWG28-16(Cable length should satisfy the power specification including the cable voltage
drop)
Input Resistance Setting Switch
Input resistance of counter input signals and general-purpose input signals can be set with
the piano switch equipped on the top and the bottom faces of the product.
5V or 12V is available by switching the switch.
Factory settings: All set
to OFF
Switch
number
Input signal Setting description
1 Phase-A input
ON :
5V, 220
OFF : 12V, 690
2 Phase-B input
ON :
5V, 220
OFF : 12V, 690
3 Phase-Z input
ON :
5V, 220
OFF : 12V, 690
4 General-purpose input
ON :
5V, 220
OFF : 12V, 690
Pull-Up Setting Switch
5V pull-up of input signals for sampling control can be enabled or disabled with the piano
switch equipped on the bottom face of the product.
Set to the switch to OFF when the other voltage such as 3.3V is used, and pull-up externally.
Set to the switch to ON when the control input signals are not used.
Factory settings: All set
to ON
Switch
number
Input signal Setting description
1
External sampling
start si
g
nal
ON : Pull-up with 5V, 10k
OFF : No pull-ups
2
External sampling
stop si
g
nal
ON : Pull-up with 5V, 10k
OFF : No pull-ups
3
External sampling
clock si
g
nal
ON : Pull-up with 5V, 10k
OFF : No pull-ups
6. Setup
Driver software API-CNT(WDM) for USB is required to setup this product. Download the
software from the CONTEC website beforehand. (https://www.contec.com/download/)
Follow the steps below to set up.
1. Software installation
STEP1: Extract the downloaded file. (ZIP)
STEP2: After the extraction, execute Setup.exe in the INF folder to install.
For Windows 10, execute Setup.exe in the Cnt_ForWin10 folder. If it is not Windows
10, execute Setup.exe in the Cnt folder.
2. Hardware installation
STEP1: Connect AC adapter to the product. Then turn the power on.
STEP2: Confirm that the Power LED of this product is lit.
STEP3: Connect the product and the host computer with a USB cable.
STEP4: Installation process will finish automatically.
After that, proceed to “3. Software initialization”.
If the "Found New Hardware Wizard" appears, select "Install the software automati-
cally" and click the "Next" button.
3. Software initialization
STEP1: Run Device Manager.
STEP2: The installed hardware appears under the CONTEC Devices node. Open the
CONTEC Devices node and select the device you want to setup. Click [Properties].
STEP3: Enter the device name in the common settings tab page and then click [OK].
The device name you set here is used later when programming.
STEP4: When you click "Diagnosis" on the common setting tab page, the diagnostic
program starts up.
For details of the diagnostic program, refer to the driver help.
You can use the default device name as it is displayed. When making changes, make
sure that the device names do not overlap among multiple devices.
Above completes the settings.
Refer to Help (\Help\ENG\APITOOL.chm) regarding API function or sample programs.
7. Physical Dimensions