ROOTECH ACCURA 3500 User guide

Category
Measuring, testing & control
Type
User guide
ACCURA 3500
High Accuracy Digital Power Meter
Added with Extension modules
Suits your various applications
User Guide[English]
Rev 1.9 2017/08/07
Page 2
Page 3
Notice
Danger
Indicates the presence of
dangerous voltage which can cause severe
injury or death to persons if proper precautions are not followed.
Warning
Alerts
the user to the presence of hazards which can cause somewhat
injury to persons, damage to property or damage to the device itself, if
proper precautions are not followed.
Note
Indicates the users attention to installation, operating and maintenance
instructions.
Electrical Symbols
Indicates alternative voltage or current.
Indicates direct voltage or current.
Installation Considerations
Installation and operation of Accura 3500 meter should be performed only by qualified,
competent personnel that have appropriate training and experience with high voltage
and current devices.
Danger
Failure to observe the following instructions may result in severe injury or death.
During normal operation of the Accura 3500 meter, hazardous voltages are
present on its terminal strips.
Standard safety precautions are followed while performing any installation or
service work[removing PT fuses, shorting CT secondaries, etc].
Do not access to terminal strips of the Accura 3500 meter after installation.
Page 4
Warning
Observe the following instructions, or permanent damage to the meter may occur.
Do not apply Accura 3500 to voltages and currents that exceed Input ratings
of PT and CT.
Limitation of Liability
Rootech Inc. reserves the right to make changes in the device specifications shown in
this Users Guide without notice. Rootech Inc. advises customers to obtain the latest
specifications of device before giving orders to confirm that the information being relied
on by the customer is up to date.
In the absence of written agreement to the contrary, Rootech Inc. assumes no liability
for Rootech Inc. applications assistance, customers system design, or infringement of
patents or copyrights of third parties by or arsing from the use of devices described
herein.
Except to the extent prohibited by applicable law, under no circumstances shall
Rootech Inc. be liable for consequential damages sustained in connection with said
product and Rootech Inc. neither assumes nor authorizes any representative or other
person any obligation or liability other than such as is expressly set forth herein.
2006 Rootech Inc.
The information contained in this document is believed to be accurate at the time of
publication, however, Rootech Inc. assumes no responsibility for any errors which may
appear here and reserves the right to make changes without notice.
Page 5
Standard Compliance
CE Approved
EN61326 and IEC61010
MEASURING EQUIPMENT
35DX
E258934
QMS-1347 KAB-QC-09
Page 6
Warranty Information
For products and software that are sold or licensed by Rootech Inc. during the period
from the date of receipt by you until the present, Rootech warrants only to the original
purchaser
The purchased products other than software shall be substantially free from material
defects in material and workmanship by Rootech for two years from the date receipt by
you.
The software itself is provided as iswithout any warranty of any kind.
Limitation of Warranty
These limited Warranties shall not apply to any product that has been subject to
alteration, accident, misuse, abuse, neglect or failure to exactly follow Power
Measurement's instructions for operation and maintenance.
In order for the original purchaser to make a claim under the warranties described
above, the original purchaser must promptly contact Rootech headquarter. After
receiving such notice, Rootech may either in Rootechs sole discretion, examine the
product at the original purchasers site or issue shipping instructions to the original
purchaser to return the relevant product to Rootech for examination at the original
purchasers expense, transportation charges prepaid.
If after examining the product Rootech reasonably confirms that such examined
product does not meet the warranties, then the original purchasers sole remedy and
Rootechs sole obligation or liability shall be, at Rootechs option, to repair, replace or
refund the price paid for that product.
Regardless of whether any remedy set forth herein fails of its essential purpose, except to
the extent the following limitation is prohibited by applicable law, Rootech shall not, in
any event or under any legal claim or theory, be liable to the original purchaser or any
other person or entity for special, indirect, incidental, punitive, liquidated, special or
consequential damages whatsoever with respect to any purchased product, including,
without limitation, business interruption, loss of use, profit or revenue, even if Rootech has
Page 7
been advised of the possibility of such damages. To the extent that a limitation or
exclusion of consequential damages are prohibited by applicable law, then Rootechs
liability shall be limited to twice the amount of the relevant purchased product.
Rootech shall not be liable for any claim- other than a claim solely for the breach of one
of the above warranties that is made in accordance with the above described
procedures- made by the original purchaser, its employees, agents, or contractors for
any loss, damage, or expense incurred due to, caused by, or related to any purchased
product
Any technical assistance provided by Rootech's personnel or representatives in system
design shall be deemed to be a proposal and not a recommendation. The responsibility
for determining the feasibility of such proposals rests with the original purchaser and
should be tested by the original purchaser.
It is the original purchaser’s responsibility to determine the suitability of any product and
associated documentation for its purposes. The original purchaser acknowledges that
100% "up" time is not realizable because of possible hardware or software defects. The
original purchaser recognizes that such defects and failures may cause inaccuracies or
malfunctions.
Only the terms expressed in these limited Warranties shall apply and no distributor,
corporation or other entity, individual or employee of Rootech or any other entity is
authorized to amend, modify or extend the Warranties in any way.
Copyright © 2006, Rootech Inc.
Headquarter
102-611, Digital Empire2, Sinwon-ro 88,
Suwon, Korea
Tel : +82-31-695-7350 Fax : +82-31-695-7399
Homepage
www.rootech.com
E-mail
supervisor@rootech.com
Page 8
Page 9
Revision History
The following versions of the Accura 3500 Users Guide have been released.
Revision # Revision date Description Firmware version
Revision 1.0 2006. 06. 30 Initial draft
Revision 1.1 2007. 04. 24 Adding a menu item of extension module
configuration
1.22
Revision 1.2 2007. 07. 13 Mounting modified
Revision 1.4 2010. 11. 09 Adding A4P2, A2P4 modules 2.00
Revision 1.5 2012. 08. 06 C
hanging DI channel in ordering
information
Revision 1.6 2013. 11. 25 C
hanging DI channel in ordering
information
Revision 1.7 2015. 05. 12 Standard compliance updated
Revision 1.8 2016. 09. 05 Voltage wiring diagram updated
Revision 1.9 2017. 08. 07 IrDA deleted
Page 10
Contents
Chapter 1 Introduction ................................................................................................................................... 14
Overview ......................................................................................................................................................................................... 14
Power Measurements, Digital/Analog Input and Output Integration.................................................... 14
Accuracy, Power Quality ................................................................................................................................................ 14
CE/UL Safety and Reliability ........................................................................................................................................ 14
Easy Adding of Modules .............................................................................................................................................. 14
Features ........................................................................................................................................................................................... 16
Measurement ..................................................................................................................................................................... 16
Power Quality ..................................................................................................................................................................... 16
Basic Module ...................................................................................................................................................................... 16
Extension Module[only one module to be chosen as option] .................................................................. 16
Communication ................................................................................................................................................................. 17
Power Supply...................................................................................................................................................................... 17
Applications ................................................................................................................................................................................... 18
True RMS Measurements robust to harmonics ................................................................................................. 18
Power Quality Analysis .................................................................................................................................................. 18
Module Structure to adapt to different requirements in the field .......................................................... 18
Compatibility with Analog Meters ........................................................................................................................... 18
High Reliability Energy Management ..................................................................................................................... 18
Parameters ..................................................................................................................................................................................... 19
Chapter 2 Mounting ..................................................................................................................................... 21
Environmental Conditions ............................................................................................................................................ 21
Enclosure Considerations ............................................................................................................................................. 21
Before You Begin ........................................................................................................................................................................ 22
Meter Overview.................................................................................................................................................................
22
Meter Dimensions ............................................................................................................................................................ 23
Step 1: Mounting ..................................................................................................................................................................... 24
Sequence .............................................................................................................................................................................. 24
Step 2: Voltage and Current Inputs ................................................................................................................................ 25
Voltage Input ...................................................................................................................................................................... 25
Current Input ...................................................................................................................................................................... 26
Wiring Diagram Using External PTs ........................................................................................................................ 27
Direct Diagram Using No PTs .................................................................................................................................... 30
Step 3: Wire the RS485 Communication ........................................................................................................................ 33
Page 11
Step 4: Wire the Power Supply and Ground Terminal ............................................................................................. 34
Power Supply...................................................................................................................................................................... 34
Ground Terminal ............................................................................................................................................................... 34
Step 5: Add a Basic Module[DIO module] ..................................................................................................................... 36
Step 6: Wire a Basic Module ................................................................................................................................................. 37
DIO Module ........................................................................................................................................................................ 37
Step 7: Wire the Power Supply and Ground Terminal of a Basic module ..................................................... 40
Power Supply...................................................................................................................................................................... 40
Ground Terminal ............................................................................................................................................................... 40
Step 8: Add a Extension Module ..................................................................................................................................... 42
Step 9: Wire a Extension Module ....................................................................................................................................... 43
DI Module ............................................................................................................................................................................ 43
DO Module ......................................................................................................................................................................... 44
AI Module ............................................................................................................................................................................ 46
AO Module .......................................................................................................................................................................... 47
A4P2/A2P4 Module ......................................................................................................................................................... 49
Step 10: Wire the Power Supply and Ground Terminal of a Exension module ........................................... 51
Power Supply...................................................................................................................................................................... 51
Ground Terminal ............................................................................................................................................................... 51
Step 11: Power Up the Meter ............................................................................................................................................ 53
Chapter 3 Meter Operation/Setup ............................................................................................................. 54
Display Mode ............................................................................................................................................................................... 55
Setup Mode .................................................................................................................................................................................. 58
Reset Mode ................................................................................................................................................................................... 60
System Mode ................................................................................................................................................................................ 61
Reactive Calculation Method...................................................................................................................................... 63
Module Mode .............................................................................................................................................................................. 65
Module Display Menu ................................................................................................................................................... 65
Module Setup Menu ...................................................................................................................................................... 69
APPENDIX A Standard Specification.......................................................................................................... 82
APPENDIX B Standard Compliance ............................................................................................................ 83
APPENDIX C Test Report ............................................................................................................................. 84
Measuring Test ............................................................................................................................................................................. 84
Reliability Test ............................................................................................................................................................................... 85
APPENDIX D Order Information ................................................................................................................. 86
INDEX ................................................................................................................................................................. 87
Page 12
Figures
Fig 1.1 Front Side ............................................................................................................................................................. 22
Fig 1.2 Rear Side ............................................................................................................................................................... 22
Fig 1.3 Basic Module[DIO Module] Rear Side ................................................................................................... 22
Fig 1.4 Front View ............................................................................................................................................................ 23
Fig 1.5 Rear View.............................................................................................................................................................. 23
Fig 1.6 Side View .............................................................................................................................................................. 23
Fig 1.7 Side View[one extension module can be added as option when ordering] ...................... 23
Fig 1.8 ANSI 4 .................................................................................................................................................................. 24
Fig 1.9 DIN96 ..................................................................................................................................................................... 24
Fig 1.10 Voltage and Current Connector ............................................................................................................. 25
Fig 1.11 Single Phase 2 Wires, Wiring Mode = 1P2U ................................................................................... 27
Fig 1.12 Three Phase 3 Wire Open Delta Using 2CTs, Wiring Mode = 3P3O ................................... 28
Fig 1.13 Three Phase 3 Wire Open Delta Using 3CTs, Wiring Mode = 3P3O ................................... 28
Fig 1.14 Three Phase 4 Wires Using 3 PTs and 3 CTs, Wiring Mode = 3P4U ................................... 29
Fig 1.15 Single Phase 2 Wire Direct , Wiring Mode = 1P2U ..................................................................... 30
Fig 1.16 Single Phase 3 Wire Direct Using 2 CTs, Wiring Mode = 1P3U ............................................ 31
Fig 1.17 Three Phase 3 Wire Open Delta Direct, Wiring Mode = 3P3O .............................................. 31
Fig 1.18 Three Phase 3 Wire Open Delta Direct Using 3 CTs, Wiring Mode = 3P3O ................... 32
Fig 1.19 Three Phase 4 Wire Direct Using 3 CTs, Wiring Mode = 3P4U ............................................. 32
Fig 1.20 Communication Wiring ............................................................................................................................... 33
Fig 1.21 Wiring of Power Supply and Ground Terminal ............................................................................... 34
Fig 1.22 Adding of a Basic Module......................................................................................................................... 36
Fig 1.23 DIO Module ...................................................................................................................................................... 37
Fig 1.24 Digital Input...................................................................................................................................................... 37
Fig 1.25 DC Relay application .................................................................................................................................... 38
Fig 1.26 AC Relay application .................................................................................................................................... 38
Fig 1.27 Wiring of Power Supply and Ground Terminal of a Basic module ....................................... 40
Fig 1.28 adding of a extension module ................................................................................................................ 42
Fig 1.29 DI Module ......................................................................................................................................................... 43
Fig 1.30 Digital Input...................................................................................................................................................... 44
Fig 1.31 DO Module ....................................................................................................................................................... 44
Fig 1.32 DC Relay application .................................................................................................................................... 45
Page 13
Fig 1.33 AC Relay application .................................................................................................................................... 45
Fig 1.34 AI Module .......................................................................................................................................................... 46
Fig 1.35 Analog Input .................................................................................................................................................... 46
Fig 1.36 AO Module ....................................................................................................................................................... 47
Fig 1.37 Analog Output ................................................................................................................................................ 47
Fig 1.38 A4P2 Module ................................................................................................................................................... 49
Fig 1.39 A2P4 Module ................................................................................................................................................... 49
Fig 1.40 A4P2/ A2P4 Module Analog Output ................................................................................................... 49
Fig 1.41 Pulse Output .................................................................................................................................................... 50
Fig 1.42 Wiring of Power Supply and Ground Terminal of a Extension module .............................. 51
Fig 2.1 Measurement Groups ..................................................................................................................................... 55
Fig 2.2 P, Q[according to general calculation] ................................................................................................... 63
Fig 2.3 DIO module channel information ............................................................................................................ 67
Fig 2.4 DI module channel information ................................................................................................................ 67
Fig 2.5 DO module channel information ............................................................................................................. 67
Fig 2.6 AI module channel information 1 ............................................................................................................. 67
Fig 2.7 AO module channel information 1 .......................................................................................................... 67
Fig 2.8 A4P2 module channel information ........................................................................................................ 68
Fig 2.9 A2P4 module channel information ........................................................................................................ 68
Fig 2.10 DIO module digital output channel 1 setup .................................................................................... 73
Fig 2.11 DIO module digital output channel 2 setup .................................................................................... 73
Fig 2.12 DO module digital output channel 1 setup 1 ................................................................................. 73
Fig 2.13 DO module digital output channel 2 setup1 ................................................................................... 73
Fig 2.14 DO module digital output channel 3 setup1 ................................................................................... 73
Fig 2.15 DO module digital output channel 4 setup1 ................................................................................... 73
Fig 2.16 A4P2 module analog output channel 1 ............................................................................................. 78
Fig 2.17 A4P2 module pulse output channel 1 ................................................................................................ 78
Fig 2.18 A2P4 module analog output channel 1 ............................................................................................. 81
Fig 2.19 A2P4 module pulse output channel 1 ................................................................................................ 81
Page 14
Chapter 1 Introduction
Overview
Power Measurements, Digital/Analog Input and Output Integration
Accura 3500 is a high accuracy digital power meter, suited to power measurements
and digital/analog input and output. This enables customers to easily meet a variety of
digital/analog requirements in the field, remarkably cutting down expenses of customers
to additionally purchase separate RTU products in existing management system. The
device is applied to applications, such as electrical facilities, intelligent building system,
factory and etc.
Accuracy, Power Quality
The measuring accuracy is the most important criterion to evaluate the reliability of
energy management system. Actually low accuracy makes it hard for customers to
precisely manage energy, causing inequality of energy between incoming feeder and
sum of load sides. Accura 3500 makes ±0.2% high accuracy measurements for voltage
and current, and conforms to IEC62053-22 class 0.5S for power and energy. This makes it
possible to solve the problem with energy inequality. Furthermore the device provides
the information of power qualities, such as voltage/current THD, harmonic analysis, and
k factor.
CE/UL Safety and Reliability
The structure- framework, circuit, fire - of Accura 3500 conforms to safety standard,
CE[IEC61010], UL[UL61010-2, 2nd edition]. Particularly the device provides pass-through
busbar, allowing CT leads to be terminated on the device. This eliminates any possible
point of failure at the device. And optic interface between meter and module
essentially disturbs danger of the existing electrical contacts.
Easy Adding of Modules
Easy adding of modules to rear side of meter provides customized extension of function
to flexibly meet a variety of applications. Accura 3500 has a basic module, called DIO
module, and an extension module, one of digital input, digital output, analog input, and
analog output modules. the extension module is selected as an option when ordering.
Page 15
Page 16
Features
Measurement
64 Sampling/Cycle True RMS
IEC 62053-22 Class 0.5S
50, 60Hz
4 Quadrant Energy
- kWh/kVARh received1, kWh/kVARh delivered1
- kWh/kVARh net[kWh/kVARh received - kWh/kVARh delivered]
- kWh/kVARh total[kWh/kVARh received + kWh/kVARh delivered]
Phase voltage, line to line voltage, current
Power, energy, power factor, frequency
Fundamental component, True RMS of current
4 Quadrant Power
Demand, peak demand, Prediction demand
Maximum, Minimum
1kWh/kVARh received is positive for view as load, kWh/kVARh delivered is positive for
view as generator”.
Power Quality
Voltage/current THD
Harmonic Analysis 1
K factor 1
1 It is available only on RS485 communication.
Basic Module
DIO Module: Digital Input/output, 8/2 channels
Extension Module[only one module to be chosen as option]
DI Module: Digital Input 12 channels
DO Module: Digital Output 4 channels
AI Module: Analog Input 6 channels
AO Module: Analog Output 6 channels 1
A4P2 Module: Analog Output 4 channels 2, Pulse Output 2 channels
A2P4 Module: Analog Output 2 channels 2, Pulse Output 4 channels
1 Analog output controlled only by RS485 communication.
2 Analog output by measuring parameters configured inside meter.
Page 17
Communication
RS485 Port[rear]
Modbus RTU Protocol
Baudrate: 1,200 ~ 57,600bps
Power Supply
AC 85 ~ 265V, 50/60Hz
DC 100 ~ 300V
Burden: 10VA
Page 18
Applications
True RMS Measurements robust to harmonics
Most of energy environments consist of nonlinear loads, such as industrial load, rectifier,
power electronic device, electric furnace and etc. this causes fatal distortion of voltage
and current waveforms. Accura 3500 makes high accuracy True RMS measurements for
voltage and current distorted with harmonics.
Power Quality Analysis
Accura 3500 provides k factor, analysis of voltage and current up to 31st harmonic, and
realtime waveform of voltage and current.
Module Structure to adapt to different requirements in the field
Easy adding of modules to rear side of meter provides customized extension capability
to flexibly meet a variety of applications. In the case of the existing IBS, DDC panel
concentrates all of input/output wiring, decreasing economical efficiency and reliability
of the overall system. Accura 3500 easily replaces the existing DDC panel, building the
optimal IBS system.
Compatibility with Analog Meters
Accura 3500 mounts directly in ANSI C39.1[4” Round] or DIN 96. this is perfect for new
installations and for existing panels. In new installations, simply use existing DIN or ANSI
punches. For existing panels, pull out old analog meters and fit the device in its cutout.
High Reliability Energy Management
The most important point to evaluate the overall data reliability of energy management
is the accuracy of meters. Accura 3500 makes ±0.2% high accuracy measurements for
voltage and current, and conforms to IEC62053-22 class 0.5S for power and energy.
Energy management gives customers various services, monitoring, cost curtailment,
demand, energy planning, and etc.
Page 19
Parameters
Realtime
1
Average
2 Total 3 Maximum 4 Minimum 5 Prediction
6
Phase voltage
L
ine to line
voltage
Current
Power Active
Reactive
Apparen
t
Energy Active
Reactive
Apparen
t
Frequency
Power factor
THD Voltage
Current
Demand Power
Current
1 Instaneous measuring. 2 Average of three phase parameters. 3 Total sum of three phase
parameters.
4 If realtime measurements exceed maximums, the maximums will be updated, the measurements
being ignored within 10msecs after power up.
5 If realtime measurements is less than minimums, the minimums will be updated, the measurements
being ignored within 10msecs after power up.
6 Prediction demand is calculated based on realtime energy.
Note
The Maximums and minimums will not be updated with no power-up. And
Page 20
measurements are displayed 5 seconds after power-up.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

ROOTECH ACCURA 3500 User guide

Category
Measuring, testing & control
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI