Dometic MasterFlush 8700 series Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

1
8700 Series
MasterFlush
Toilets
INSTALLATION
Macerator Toilet
Installation..................... 3
EN
Mazerier-WC
Installation.................... 13
DE
WC dilacérateur
Installation .................... 23
FR
Inodoro triturador
Instalación .................... 32
ES
Toilet met versnijdingspomp
Installatie ..................... 41
NL
WC di macerazione
Installazione ................... 50
IT
Silppuripumppu-wc
Asennus...................... 59
FI
Macerator-toalett
Installation .................... 68
SV
Findelingstoilet
Installation .................... 77
DA
Macerator-toalett
Montering..................... 86
NO
2
Dometic 8700 Series MasterFlush Toilet
A
A
BC
D
E
F
B
CD
F
E
G I
J
K
H
N
L
M
A
A
C
B
B
C
1
4
5
2
3
1
1
2
2
4
4
5
6
7
8
9
11 10
3
3
3
Dometic 8700 Series MasterFlush Toilet Notes on using the manual
1 Notes on using the manual .................................................3
2 General safety instructions ..............................................3 - 4
3 Components ............................................................5
4 Specications ...........................................................6
5 Installation ..........................................................7 - 13
6 Customer service........................................................14
RV Installation Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1 Notes on using the manual
Note
Supplementary information for operating the device.
fig. 1 A, page 2 : This refers to an element in an illustration. In this example, item A in
gure 1 on page 2.
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and
impair the function of the device.
EN
Table of contents
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faultyassemblyorconnection
• Damagetotheunitfrommechanicalinuences,misuseorabuse
• Alterationstotheunitwithoutexpresswrittenpermissionfromthemanufacturer
• Useforpurposesotherthanthosedescribedintheoperatingmanual
2.1 Warnings – marine applications
The following statements must be read and understood before installing, servicing and/or
operating this product on a boat. Modification of this product may result in property damage.
Dometicrecommendsthataqualiedmarinetechnicianorelectricianinstallorservicethisproduct.
Equipmentdamage,injurytopersonnelordeathcould resultfromimproper installation. DOMETIC
ACCEPTS NO RESPONSIBILITY OR LIABILITY FOR DAMAGE TO EQUIPMENT, OR PERSONAL
INJURYORDEATHTHATMAYRESULTFROMIMPROPERINSTALLATION,SERVICEOROPERATION
OFTHISPRODUCT.
4
Dometic 8700 Series MasterFlush ToiletGeneral safety instructions
Caution! Hazard of Flooding
IftoiletusesrawwaterforushingatANYtime,arawwaterpumpcontrolledbyanauto-
maticallyoperatingdemandswitchMUSTNOTbeinstalled.Iftheonboardwatervalveor
any plumbing connections were to leak, the automatically operated pump would start and
couldoodtheboat.Failuretocomplycancauselossofpropertyandlife.
Caution! Hazard of Flooding
Beforebeginninganyworkonthisproduct,besurethatallelectricalpowertotheunithas
beenturnedoffandthatseacocksareintheCLOSEDorOFFposition.Failuretodosocan
resultinoodingwhichcancauselossofpropertyandlife.
Caution! Hazard of Shock or Fire
Always use recommended fuse, circuit breaker and wire size. Failure to do so can result in
re that can cause the loss of property and life.
Caution!
Overllingtheholdingtankcancreateseriousdamagetothesanitationsystem,suchas
rupturing the holding tank and releasing tank contents into the bilge. To prevent this pos-
sibility,Dometicrecommendsusingthe“full”tankshut-downrelayinthetoilet’selectronic
controlmodule.The“full”signalfromtheholdingtankcanbegeneratedbyanoptional
DometicDTM01CtankmonitororDTM04four-leveltankmonitorsystem.
Caution! Hazard of Flooding
IftoiletrimisbelowthewaterlineatANYtime(duringanyconditionsofheel,loadortrim)
andisconnectedtoANYthrough-the-hullttings,properlypositionedventilated(vented)
loopsMUSTbeinstalledinintake*ordischargepipingtopreventpotentialbacksiphonage
ofseawaterintotheboat.Failuretodosocanresultinoodingwhichcancauselossof
property and life.
* if connected to raw water
Caution! Hazard of Flooding
IftoiletisconnectedtoANYthrough-the-hullttings,ALLexiblehosesmustbeofmarine
sanitationqualityandmustbesecuredtoANYttings(suchasthoseatseacock,vented
looportoilet)withtwostainlesssteel,worm-drivehosebandclampsateachconnection.
ConnectionsMUSTbecheckedfrequentlyforintegrity.Failuretocomplycanresultin
oodingwhichcancauselossofpropertyandlife.
Caution! Hazard of Flooding
IfthetoiletisconnectedtoANYthrough-the-hullttings,properlyinstalledseacocksMUST
beinstalledinallpipingconnectedtothrough-the-hullttings.SeacocksMUSTbeeasily
accessible to all users of the toilet or secondary valves tted in hoses where they are easily
accessible.AllvalvesMUSTbefullborevalvesandofmarinequality.Screw-to-closegate
valvesarenotrecommended.Failuretodosocanresultinoodingwhichcancauseloss
of property and life.
5
Dometic 8700 Series MasterFlush Toilet Components
3 Components
(g.1 ,page2)
Ref. Description
A Macerator toilet
B Dometicushswitch/statuspanel
C Control module
D4-wire cable to toilet
ECablefromDometicushswitch
(RJ45ethernetcable)
F6-wirecabletoushswitch/
status panel
G Incoming electrical power wires
H Powerwirestorawwaterpump(opt.)
IWirefrom“fulltank”signal
J Floor mounting hardware kit
K Floor mounting template
L Flushhandle(alternatemodel)
MDometicstatuspanel
(forushhandlemodelonly)
NCableforushhandle,statuspanel
(forushhandlemodelonly)
Ref. Description
1 Anti-siphon valve
2 Vacuum breaker
3Dischargeloopoutlet
4Dischargeadaptertting
5Dischargehosetting
6 Macerator pump
7 Water valve
8 Water line - 0.5 in. NPT tting
9 4-pin cable connector
10 Flushhandle(alternatemodel)
11 Flush handle cable connector
Refertocompletepartslist(packedseparately)
for additional information.
(g. 2,page2)
6
Dometic 8700 Series MasterFlush ToiletSpecifications
4.2 Minimum System Requirements
4.3 Dimensions (g. 3
,page2)
Ref. Dimension
A19in./483mm
B 14in./356mm
C21.5in./546mm
D 17.5in./445mm-seatheight
E17in./432mm
F33.5in./851mm-seatlidup
Ref. Dimension
A2in./51mm
B 3.25in./83mm
C0.4375in./11mm
Ref. Dimension
A19in./483mm
B 15.75in./400mm
C21.5in./546mm
D 17.5in./445mm-seatheight
E17in./432mm
F33.5in./851mm-seatlidup
Ref. Dimension
A4.187in./106mm
B 5.25in./133mm
C2.063in./52mm
Models with wall-mounted
flush touchpad
Dometic flush switch/status panel
(g. 4
,page2)
Models with flush handle
Control module (g. 5
,page2)
4 Specifications
4.1 Materials
Toilet: vitreous ceramic
Macerator pump body: glass-lled polypropylene
Control module housing:ABS
Dometic switch panel frame:ABS
Dometic switch panel: polycarbonate resin
Flush handle:platedbrass(onapplicabletoilet
models)
Electrical Circuit breaker 20amps/12VDC;15amps/24VDC
Wiring* 12ga.(upto20ft./6.1mfrombreaker)
Water
Supply
Fitting 0.5 in. NPT
Flow rate 4gpm/15lpm
Maximumowpressure 40PSI/276kPa
Discharge
Inside diameter 1.5in./38mmor1in./25mm
Horizontalrun** 98ft./30mmaximum
Verticalrun** 9.8ft./3mmaximum
*ForRVinstallation,seeAppendixonpage15.
**Horizontalandverticalrundistancesarenotcumulative.Checkforadequatedischargeowifinstallationnearsoneoftheselimits.
Specicationsaresubjecttochangewithoutnotice.
7
Dometic 8700 Series MasterFlush Toilet Installation
5 Installation
5.1 Fresh water system layout - marine application
5.2 Raw water system layout - marine application
(additional components required)
Note
Usecoldwateronly.Includeshut-offvalveinwaterlineformaintenancepurposes.
Notes
Usecoldwateronly.Includeshut-offvalveinwaterlineformaintenancepurposes.
Useprimaryandsecondaryrawwaterlters.
RawwaterpumpMUSTNOTbedemand-type.Pumpiscontrolledbycontrolmodule.
Installventedloopasshown.Itmustbeequippedwithintegralcheckvalvethatpermitsairintolineto
prevent siphoning.
Dometicmaceratortoiletscanoperatewithan
onboard pressurized freshwater system with a
minimumowrateof2.5gpm(9.5lpm)atthe
toilet.Onboardfresh-waterdemandsystems
include a water pump that automatically draws
water from a water storage tank when a valve
Dometicmaceratortoiletscanushonseawaterbutrequireaseparatepumpforthispurpose.The
pumpisactivatedbythesignalfromthetoilet’selectroniccontrolmodulethatwouldoperatethe
integral water valve in a fresh water system. If the raw water pump draws more than 18 amps of
current,a12or24VDCelectricalrelaymustbeinstalled.
anywhere in the piping system is opened.
Dometictoiletsareequippedwithanelectrically
operatedwatervalveandabackowpreventer
to prevent contamination of onboard potable
supplies.
6
7
VENT
FITTING
SEACOCK
VENT
FILTER
DISCHARGE
PUMP
DECK
DISCHARGE
“FULL” LEVEL
PROBE (opt.)
CONTROL
MODULE
CONTROL
MODULE
MACERATOR
TOILET
MACERATOR
TOILET
FLUSH
SWITCH
PANEL
FLUSH
SWITCH
PANEL
0.5 in./13 mm
FRESH WATER
HOSE
0.5 in./13 mm
WATER HOSE
0.625 in./16 mm HOSE
1 in./25 mm HOSE
SEACOCK
TO SUCTION SIDE OF
RAW WATER PUMP
FINE WATER FILTER
(100 MESH)
SMALL ENGINE INTAKE STRAINER (COARSE)
RAW WATER
PUMP
WATER LINE
HOLDING TANK
(cut-away view)
VENTED LOOP/CHECK VALVE
Mustbe8in./203mmabovewater
line during all conditions of heel,
trim or load
8
Dometic 8700 Series MasterFlush ToiletInstallation
5.3 Toilet system with wall touchpad and through-the-floor connections
- all applications
1. Placeoormountingtemplateindesiredlocation(g. 8).Foroptimalusercomfort,makesure
wallsorotherinteriorxturesareatleast11in.(279mm)awayfromcenterlineoftemplate.
2. Center punch all holes through template.
3. Removetemplatefromoor.Drillallaccessholesasindicatedontemplate(g. 9).
4. Planushswitchpanelandelectroniccontrolmodulelocationssothatelectricalconnectionscan
bemadewithcablesprovided.Besuremoduleandwirescannotgetwet.
5. UseDometicwallswitchtemplatetomarklocationoffastenerandaccessholes.Drill1in.
(25mm)hole,thenfastenpanelbrackettowall(g. 10 ).
6. RouteDometicushswitchpanelcablefromcontrolmoduletoaccessholeatushswitchpanel
location.Attachcabletoushswitchpanel,thensnapthepanelcoverontothepanelbracket
(g. 10 ).
7. Installcontrolmoduleincool,drylocation,thenattachDometicushswitchcabletocontrol
module(g. 11 ) .
8. With electrical power off, complete wiring connections to control module. Refer to Section 5.6,
Wiring schematic - Dometic flush touchpad or Vimar/Gewiss controls.
9. Route4-wirecontrolmodulecable(g. 1D,page2)totoiletthroughaccessholeinoor.
10.Routewatersupplyanddischargeplumbingtotoiletaccordingtosystemrequirements(Section
4.2).Makesuretoprovideextradischargehoselengthtoassureeasyconnectiontotoilet
(g. 12 ,page9).
8910
Note
WheninstallingVimarorGewissushswitch/statuspanel,
disregardinstructionsforinstallingDometictouchpadswitch.
Install Vimar or Gewiss component on wall according to
manufacturer’sinstructions,thenattachendofcableto6-wire
connector(g. 1D,page2)atcontrolmodule.
11
9
11.Loosenbandclampondischargeloopoutletandremovedischargeadaptertting/hose
ttingassembly(g. 13 ) .
12.Lubricatedischargettingassemblyandinsideendofdischargehosewithliquiddishwashing
soap. Push discharge tting assembly into discharge hose and connect with two hose clamps.
Besuretopositionhoseclampscrews180°apartfromeachother(g. 14 ).Placetoiletnear
accessholesandoorbrackets.
13. Connect toilet water line and 4-pin connector to water supply line and control module cable.
14.Positiontoiletoveroorbracketsandtilttoiletupfromback.Pushdischargeassemblytting
andhoseupintodischargeloopoutlet.Lowertoilettooorandtightenbandclamp(g. 15 ).
15.Turnonwatersupplyandelectricalpowertotoilet,andcheckforleaks.Press“Flush”switch
(g. 42,page2).Ifleakoccurs,tightenconnection.
16.Atoormountingholes,drillpilotholesforhex-headoorfasteners.Installfastenersand
washers using a 3/8in.(10mm)socketwrench(g. 16 ).
17.Coveroorfastenerswithplasticcovers(g. 17 ).
Dometic 8700 Series MasterFlush Toilet Installation
12
15 16 17
14
13
10
Dometic 8700 Series MasterFlush ToiletInstallation
5.4 Toilet system with flush handle and through-the-floor connections
- all applications
1. Follow steps 1-3 in Section 5.3.
2. Plan electronic control module and status panel locations so that electrical connections can be
madewithcablesprovided.Besuremoduleandwirescannotgetwet.
3. UseDometicwallswitchtemplatetomarklocationoffastenerandaccessholesforstatuspanel
(g. 1M,page2).Drillwiringaccesshole,thenfastenpanelbrackettowall.
4. Routeushhandle/statuspanelcable(g. 1N,page2)fromcontrolmodulelocationtotoilet
andstatuspanel.RouteDometicushhandlecablesection(withorangeconnector)toaccess
hole at toilet location. Route other section of cable through status panel access hole and
connect to status panel wire. Attach status panel to panel bracket on wall.
5. Installcontrolmoduleincool,drylocation,thenattachDometicushswitch/statuspanelcable
tocontrolmodule(g. 18 ) .
8. With electrical power off, complete wiring connections to control module. Refer to Section 5.7,
Wiring schematic - Dometic flush handle and status panel.
9. Route4-wirecontrolmodulecable(g. 1D,page2)totoiletthroughaccessholeinoor.
10.Routewatersupplyanddischargeplumbingtotoiletaccordingtosystemrequirements(Section
4.2).Makesuretoprovideextradischargehoselengthtoassureeasyconnectiontotoilet
(g. 19 ) .
11. Follow steps 11-13 in Section 5.3 to connect discharge plumbing and 4-pin connector at toilet.
12.Connect3-pinushhandlecableconnectorto3-pinwirefromcontrolmodule(g. 20 ) .
13.Followsteps14-17fromSection5.3tonishinstallationandtesting.Pressushhandledown
when testing operation and checking connections.
18 20
19
11
Dometic 8700 Series MasterFlush Toilet Installation
5.5 Toilet system with through-the-wall
connections
1. To route wiring and plumbing connections through the wall,
useoortemplatetolocatetheverticalcenterlineofeach
hole.
2. Place toilet in proper position and mark horizontal centerlines
(g. 21 ) .
3. Drillholessizesasindicatedontemplate.
4. Route wiring and plumbing through holes, then follow toilet
installation instructions beginning at Section 5.3 or Section
5.4, step 4.
21
12
DOMETIC TOUCHPAD
CONNECTOR FOR
DOMETIC TOUCHPAD
“FULL” FLOAT
Dometic 8700 Series MasterFlush ToiletInstallation
Caution – Hazard of Shock or Fire
Always use recommended fuse, circuit
breaker and wire size. Failure to do so can
cause the loss of property and life.
Note
Each toilet must have its own circuit breaker
or fuse.
All installation factors must be in accordance
withABYC/ISOelectricalstandards.
Always use crimp-style wire connections.
Donotusewirenuts(theycorrode).
5.6 Wiring schematic - Dometic flush touchpad or Vimar/Gewiss controls
22
13
Dometic 8700 Series MasterFlush Toilet Installation
Caution – Hazard of Shock or Fire
Always use recommended fuse, circuit
breaker and wire size. Failure to do so can
cause the loss of property and life.
Note
Each toilet must have its own circuit breaker
or fuse.
All installation factors must be in accordance
withABYC/ISOelectricalstandards.
Always use crimp-style wire connections.
Donotusewirenuts(theycorrode).
5.7 Wiring schematic - Dometic flush handle and status panel
23
“FULL” FLOAT
STATUS PANEL
14
Dometic 8700 Series MasterFlush ToiletCustomer Service
There is a strong, worldwide network to assist
in servicing and maintaining your sanitation
system. For the Authorized Service Center near
you,pleasecallfrom8:00a.m.to5:00p.m.(ET)
Monday through Friday.
Youmayalsocontactorhaveyourlocal
dealercontactthePartsDistributornearest
youforquickresponsetoyourreplacement
parts needs. They carry a complete inventory
fortheDometicproductline.
Telephone: 1800-321-9886 U.S.A.andCanada
330-439-5550 International
Fax: 330-496-3097 U.S.A.andCanada
330-439-5567 International
Website: http://www.Dometic.com
6 Customer Service
15
CONVERSION TABLE
Wire – AWG to mm2Feet to Meters
AWG 14 12 10 Ft 10 15 20 30 50
mm22.5 4.0 6.0 M3.1 4.6 6.1 9.2 15.2
Wire size per length of run* 0-15 ft. 16-30 ft. 31-50 ft.
12voltsDC #14 #12 #10
*Distancefromcircuitbreakertoelectroniccontrolmodule.
WIRE SIZING CHART
WheninstallingaDometicmaceratortoiletinarecreationvehicle,pleaseusethefollowingwiring
information.
Warning – recreation vehicle applications
The following must be read and understood before installing, servicing and/or operating this product
on a recreation vehicle. Modification of this product may result in property damage.
DometicrecommendsthataqualiedRVtechnicianorelectricianinstallorservicethisproductwith
regardtoallapplicablecodesandregulations.Equipmentdamage,personalinjuryordeathcouldresult
fromimproperinstallation.DOMETICACCEPTSNORESPONSIBILITYORLIABILITYFORDAMAGETO
EQUIPMENT,ORPERSONALINJURYORDEATHTHATMAYRESULTFROMIMPROPERINSTALLA-
TION,SERVICEOROPERATIONOFTHISPRODUCT.
Installation notes
• Eachtoiletmusthaveitsowncircuitbreakerorfuse.
• Wiresizesmustbeappropriatefortheinstallation.Allotherinstallationfactorsmustbeinaccordance
withISOelectricalstandards.
• Alwaysusestrandedcopperwire(preferablytinned).
• Alwaysusecrimp-typewireconnections.Donotusewirenuts(theycorrode).
Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size.
Failure to do so can cause the loss of property and life.
Dometic 8700 Series MasterFlush Toilet RV Installation Appendix
Wiring / Electronic Control Module Connections
16
Dometic 8700 Series MasterFlush Toilet
DOMETIC CORPORATION
SANITATION DIVISION
13128 SR 226 | PO BOX 38
BIG PRAIRIE, OHIO 44611 USA
www.Dometic.com
®Registered;™TrademarkofDometicCorporation
©DometicCorporation
600346369 0201/13
DometicGroupisacustomer-driven,world-leading
provider of leisure products for the RV, automotive,
truck and marine markets. We supply the industry and
aftermarket with a complete range of air conditioners,
refrigerators, awnings, cookers, sanitation systems,
lighting,mobilepowerequipment,comfortandsafety
solutions,windows,doorsandotherequipmentthat
make life more comfortable away from home.
DometicGroupsuppliesawiderangeofworkshop
equipmentforserviceandmaintenanceofbuilt-inair
conditioners.DometicGroupalsoprovidesspecially
designed refrigerators for hotel rooms, ofces,
wine storage and transport and storage of medical
products.
Ourproductsaresoldinalmost100countriesandare
produced mainly in wholly-owned production facilities
around the world.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Dometic MasterFlush 8700 series Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI