Ozone OZFDL02 User manual

Type
User manual
SMART LOCK USER MANUAL
Special Attention:
It is recommended to keep the mechanical keys at a safe place in case of emergency.
Please replace the batteries if you are getting low battery alert/notification.
Please read this manual carefully before installing the product and keep it with you for future
reference.
1 .
2.
3.
Model: OZ-FDL-02 Std Black/SC
1. Lock Structure
2. Mortise
1
Dead Bolt SS304 : 15(L) x 8(W) x 35(H)mm
Tested ² 500000 cycles
70mm
270mm
Battery Cover
Back Panel
26mm
Front Panel
Keyhole
90mm
Adjustable range from
56mm to 110mm
110mm
56mm
70mm
20mm
Fingerprint
Scanner
Keypad
RFID Card Scanner
50mm
Emergency
Power Supply
148mm
LCD Display
22mm
240mm
60mm
174mm
85mm
75mm
15mm
Latch
Dead Bolt
3. Installation
3.1 Turn the handle
Notice: Adjust the handle according to door opening direction.
Front panel:
1. Loose four screws.
2. Change the handle direction according to door opening direction.
3. Reinstall the screws after adjusting the handle direction.
2
1. Loose four screws 2. Left open the handle
towards the left, right open
the handle towards the right
3. Reinstall the screw after
adjusting the direction
Back panel:
1. Loose four screws.
2. Change the handle direction according to door opening direction.
3. Reinstall the screws after adjusting the handle direction
1. Loose four screws 2. Left open the handle
towards the left, right open
the handle towards the right
3. Reinstall the screw after
adjusting the direction
3.2 Installation Diagram
Step 1 : Install Lock body Step 2 : Install sliding screw
casing and fixed front panel
Step 3 : Connect front and
back panels wires Step 4 : Install back panel
Step 5 : Install AAA batteries
The screw casing
place is adjustable
from 55mm to
100mm from the
square shaft
depending on the
location of the
holes.
Keep arrow direction upward as shown.
3
4. Specifications
Front Panel Size
Back Panel Size
Weight
Access Modes
Color Options
Compatible Door Type
Working Voltage
Door Thickness
Storage Capacity
Working Temperature
Working Humidity
Low Voltage Alarm
270*70*20mm
270*70*20mm
Silver
Black
3KG
Fingerprint
Password
Card
Mechanical key
Aluminum door
Wooden door
Metal door
6V/8x (AAA Batteries)
35-60mm
1000 RFID card + Password
200 Fingerprints
-25℃-60
20%-90%
Less than 4.5V
4
5. Features:-
E Semiconductor fingerprint sensor(508dpi)
E Passage mode function
E Universal handle
E LCD screen display Date & Time, User ID access & User unlock records
E Voice guided operation
E Dual combination mode
E Auto secure & break-in alarm
E Volume setting function
E Auto locking time setting function
E Anti-theft Password
E Smart freeze
E Emergency power supply through USB
Material of Lock Body
Material of Lock
SS 304
Zinc Alloy
Note : The lock can be opened using default code 123456 followed by # in trial mode
6. Operating instructions
Key
2
8
4
Function of the key
6.1 Key Manual
UP
DOWN
LEFT
6RIGHT
EXIT; Long press for 3s to enter the menu
ENTER
6.2 Setting
Device Reset
Method 1: Open lock back panel
cover plate >>> press the reset
buttons for 5 seconds. A prompt will
be place once it's reset successfully.
Method 2:
Press”*” key for 3s
to enter into the
menu and provide
admin password or
fingerprint
Select 'system set'
and press”#”
confirm
'Succeed' message
will appear on
successful reset.
Choose “yes” and
press”#” confirm
Choose 7 for
initialization and
press”#” confirm
5
Reset Button
User Management
6
Enter the menu: Long press the “*” key for 3 seconds to enter the menu.
(if the administrator has been set up, please first verify the administrator through the administrator’s
fingerprint password or card.
Note1: You can register fingerprint,
password or card by clicking the
Ÿ(2)” or “(8)” key žpress “#”, follow
the prompts to register the same.
2. Add Password
3. Add Card
Please first verify the administrator, then
can add user operation as Note1.
You can choose which user you want to delete by
clicking the “Ÿ(2)” or (8)” key ž press “#” ž choose
“Yes
You can choose which user you want to modify by
clicking the “Ÿ(2)” or (8)” key ž press “#” ž choose
“Yes
Main Menu
1. Add Menu
2. Add user
3. Del User
4. Modify User
5. System User
6. View Info
Set Date & Time
1. Set Time
2. Volume
3. Passage Mode
4. Locking Time
5. Double Verify
6. Language
7. Initialization
1. Record
2. Memory Used
3. F-Version V4.0
You can increase or decrease the
volume by clicking the “Ÿ(2)” or “(8)”
key ž press “#”
You can click “Ÿ(2)” or (8)”
key ž press “#” to turn on or turn off the
passage mode.
You can increase or decrease the lock delay
time by clicking “Ÿ(2)” or “(8)” key ž
press “#”
Click “Ÿ(2)” or (8)”
key ž press “#” to turn on or turn off the
double verify function.
1. Choose Language
1. To view lock records.
2. To view memory used.
3. To view firmware version.
Click “Yes” ž Press “#” ž to complete
the initialization process
1. Add Finger
2. Add Password
3. Add Card
1. Add Finger
Packing List
Picture
Picture
Name
Name
Quantity
Quantity
Front Panel
Strike Plate
1
1
Back Panel
Strike Box
1
1
User Manual
Mechanical Key
1
2
Mortise (Lock Body)
Card
1
3
Picture
Name Fixing screws 1
(For Battery Cover)
Opposite
Pull Screw Sliding Screw Sliding
Screw Casing
Quantity 1 3*1 2 2
Picture
Name Pointed Screw
(For Wooden Door)
Fixing Screws 2
(For Aluminum Door)
Waterproof
Rubber Plate
Quantity 4 4 2
Cutout Template
1
For more details, please visit www.ozonesecutech.com
Ozone Secutech PVT. LTD.
Operations Office : Plot No. 548, Phase, V, Udyog Vihar, Gurugram, Haryana - 122016, India
Head Office : H-40, Bali Nagar, New Delhi - 110015, India
Customer Care No. : +91-11-45576666
Email : customercare@ozonesecutech.com I Website : www.ozonesecutech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Ozone OZFDL02 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI