COL-MET AF-14-10-26-RF-05 Operating instructions

Category
Flat panel accessories
Type
Operating instructions

This manual is also suitable for

D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:50
SHEET 1 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:50
SHEET 1 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
REFER TO THE INCLUDED PACKING LIST FOR MORE
INFORMATION ON PARTS AND PART NUMBERS.
CONTENT PAGE
PLENUM INTRO 2
PLENUM RIGHT CORNER ASSEMBLY 3
PLENUM RIGHT CORNER FILTER INSTALL 4
PLENUM LEFT CORNER ASSEMBLY 5
PLENUM TOP PANEL INSTALL 6
PLENUM ROOF INSTALL 7
WALL INSTALL 8
ROOF INSTALL 9
WALL AND ROOF INSTALL CONT. 10
FRONT FACE AND ACCESS DOOR INSTALL 11
DOOR INSTALL 12
ELECTICAL INSTALL 13
CROSSFLOW INSTALL MANUAL
PLENUM INSTALL INSTRUCTIONS
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:40
SHEET 2 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:40
SHEET 2 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 3 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 3 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
PLENUM INSTALL INSTRUCTIONS
E17
E3
E16
E8
E2
ANCHOR TIE CHANNEL E16 TO THE FLOOR1.
ATTACH PANEL E8 TO CHANNEL E16 WITH 2.
SUPPLIED 5/16"Ø NUTS AND BOLTS
(SEE FIG. 1)
ANCHOR TIE CHANNEL E17 TO THE FLOOR3.
ATTACH PANELS E3 & E2 TO TIE CHANNEL E174.
ATTACH PANELS E2 & E85.
FIG. 1
2. ATTACH PANEL E12 TO PANEL E8 & E11
1. ATTACH PANEL E11 TO PANEL E3
E12
E11
PLENUM INSTALL INSTRUCTIONS
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 4 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 4 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
E1
E2
E17
E11
E8
E16
PLENUM INSTALL INSTRUCTIONS
E12
REPEAT STEPS 1 & 2 FOR THE LEFT SIDE OF THE PLENUM
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 5 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 5 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
CONDIT IONS TO BE SUPPL I ED BY OTH E R S .
ADDIT I ONAL DUC TWORK SU P PORT TO SU I T FIEL D
ALL ANC H O R B O L T S TO BE SUP P L IED BY OT H E R S.
E7
E9
E4
E3
E14ATTACH PANEL E3 TO JOINTHE TWO HALVES 1.
OF THE PLENUM
ATTACH PANEL E4 IN SIMILAR FASHION2.
ATTACH PANEL E73.
ATTACH DOOR STOP E14 TO PANEL E7 4.
(SEE FIG. 2)
ATTACH PANEL E9 TO PANEL E115.
FIG. 2
PLENUM INSTALL INSTRUCTIONS
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 6 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 6 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
E6
E5
E5
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 7 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 7 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
PLENUM INSTALL INSTRUCTIONS
ATTACH PANEL E51.
ATTACH PANEL E62.
ATTACH PANEL E53.
1
12
2
1
14
WALL AND ROOF INSTALL INSTRUCTIONS
ANCHOR TIE CHANNEL 1.
12 TO THE FLOOR
ATTACH PANEL 1 TO 2.
PLENUM AND TIE
CHANNEL 12
ATTACH PANEL 2 TO 3.
PANEL 1 AND TIE
CHANNEL 12
ATTACH PANEL 1 TO 4.
TIE CHANNEL 12 AND
PANEL 2
ATTACH TIE CHANNEL 5.
14 TO ALL PANELS
THE FOLLOWING STEPS ARE TO BE COMPLETED SIMULTANEOUSLY FOR BOTH SIDES
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 8 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 8 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
E15
1
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 9 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 9 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
WALL AND ROOF INSTALL INSTRUCTIONS
ATTACH PANEL 1 TO PLENUM AND TIE CHANNELS1.
ATTACH PANEL 2 TO PANEL 1 AND TIE CHANNELS2.
ATTACH PANEL 1 TO TIE CHANNELS AND PANEL 23.
CONDIT IONS TO BE SUPPL I ED BY OTH E R S .
ADDIT I ONAL DUC TWORK SU P PORT TO SU I T FIEL D
ALL ANC H O R B O L T S TO BE SUP P L IED BY OT H E R S.
WALL AND ROOF INSTALL INSTRUCTIONS
REPEAT STEPS 6 & 7 UNTIL YOU HAVE WHAT IS SHOWN HERE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 10 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 10 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
10
1
15
11
1
3
5
5
4
7
8
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 11 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:35
SHEET 11 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
WALL AND ROOF INSTALL INSTRUCTIONS
ATTACH BOTTOM TIE CHANNEL 10 ON LEFT SIDE1.
ATTACH BOTTOM TIE CHANNEL 11 ON RIGHT SIDE2.
ATTACH LEFT WALL PANEL 13.
ATTACH TOP TIE CHANNEL 154.
ATTACH ACCESS DOOR ON RIGHT SIDE TO 5.
BOOTH
ATTACH PANEL 36.
ATTACH TOP RIGHT TIE CHANNEL 15 ON RIGHT 7.
SIDE
ATTACH PANEL ROOF PANEL 18.
ATTACH TIE CHANNEL 8 AND 7 ON FRONT OF 9.
BOOTH
ATTACH PANEL 5 TO BOTH SIDES10.
ATTACH (4) PANEL 1411.
ATTACH LEFT DOOR 1.
SIDE BY BOLTING 10
GAUGE DOOR CHANNEL
TO PLENUM PANELS
REPEAT FOR OPPOSITE 2.
SIDE
DOOR INSTALL INSTRUCTIONS
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:30
SHEET 12 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:30
SHEET 12 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
HAVE A CERTIFIED ELECTRICIAN INSTALL THE LIGHTS,
FAN, MANOMETER AND AIR SOLENOID VALVE.
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:30
SHEET 13 OF 13
DO NOT SCALE DRAWING
CrossFlow Instructions
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT: 6489.69
SCALE: 1:30
SHEET 13 OF 13
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CrossFlow Instructions
DWG TITLE
INSTALL ELECTRICS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

COL-MET AF-14-10-26-RF-05 Operating instructions

Category
Flat panel accessories
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document