Tripp Lite ULTRACOAX User manual

Category
Surge protectors
Type
User manual

This manual is also suitable for

1
Copyright © 2000 Tripp Lite. All rights reserved. Isobar
®
is a registered trademark of Tripp Lite.
1111 W. 35th Street
Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
Owner's Manual
ISOBLOK, ISOFAX,
ULTRABLOK, ULTRACOAX,
ULTRACOPY, ULTRAFAX
Isobar
®
Premium Direct Plug-In
Surge Suppressors (120V)
FRANÇAIS : p. 5
ESPAÑOL : p. 9
Storage & Service: p. 5
Specifications: p. 6
Warranty & Insurance: p. 6
Install your surge suppressor indoors, away from excess moisture, heat and dust.
Connect your surge suppressor to a grounded AC power outlet. Do not remove or modify the ground pin
of the surge suppressor's plug. Do not use two-prong adapters with the surge suppressor's plug.
Do not use mounting tab and screw (provided with select models) in Canada. Canadian regulations
prohibit permanent mounting of these surge suppressors. Use of the mounting tab in Canada will void
your insurance and warranty.
Your surge suppressor does not require maintenance. Do not open your surge suppressor for any
reason. There are no user-serviceable parts inside.
Safety
Quick Installation
Basic Operation: p. 4 - 5
Safety: p. 2
Plug surge suppressor into a 3-wire,
grounded, 60 Hz.,120V electrical outlet.
All models except the ULTRACOPY should be plugged into
standard NEMA 15-amp wall sockets.
The ULTRACOPY must be plugged into a NEMA 5-20R 20-amp
receptacle.
Optional: secure surge suppressor with
outlet's cover mounting screw.
Screwing the surge suppressor to the outlet will prevent the unit
from being accidentally disconnected.
The spring steel mounting tab on select models should be adjusted
until it is flush with the surge suppressor's rear, then screwed into
place.
Plug your electrical equipment into your
surge suppressor's outlets.
You may safely connect a total load of no more than 15 amps
(20 amps for the ULTRACOPY model) to your surge suppressor.
Your electrical equipment is now protected from AC surges on the
power line.
2
1
3
9906059 Direct Plug-In Isobar Owner's Manual FINAL.p65 8/25/00, 10:58 AM1
2
Fax/Data Line Connection
(ISOFAX & ULTRAFAX Models Only)
Connect a phone cord directly from
the telephone jack to the "IN" jack of
your surge suppressor.
Your surge suppressor must be the first item in line from the
telephone jack for it to protect against surges on the fax/data line.
Your surge suppressor can only protect against fax/data line
surges if it is properly connected to a grounded AC outlet.
Connect a phone cord from the device to be protected to the
"OUT" jack of your surge suppressor.
ISOFAX models can protect TWO lines on one cable simultaneously. If you have an ISOFAX and
want to protect two lines that do NOT travel through one cable, you must use "Y" splitters
appropriate to your application to adapt them to your surge suppressor.
2
1
Coaxial Cable Connection
(ULTRACOAX Model Only)
Connect the source coaxial cable from its
wall jack to the "COAX IN" jack of your
surge suppressor.
Your surge suppressor must be the first item in line from the
wall jack for it to protect against surges on the coaxial cable.
Your surge suppressor can only protect against coaxial cable
surges if it is properly connected to a grounded AC outlet.
Connect a coaxial patch cord from the device to be protected to
the surge suppressor's "COAX OUT" jack.
2
1
Indicator Lights
Indicator light descriptions apply when the UPS is plugged into a wall outlet.
Protection Present (or unlabeled) (All Models)
This green LED will be lit so long as all the surge suppression components of your unit are intact and providing full
protection against spikes and surges. If it is not lit, the unit has lost part of its surge suppression capabilities and
should be returned for repair, though it is still usable and will provide limited surge suppression.
Line OK (Select Models Only)
This green LED lights up whenever 120V AC power is present with no wiring faults detected. It indicates that the
supplied power is safe for connected equipment.
Fault (Select Models Only)
This red LED lights up if the surge suppressor detects a wiring fault. The unit can detect if the phases are reversed,
the ground is missing, the receptacles are loose and other wiring faults, but cannot indicate every possible wiring
problem. If this LED lights up, contact a qualified electrician to repair your wiring.
This multicolored light displays 7 separate UPS battery charge conditions. It will turn from red (low) to yellow (medium)
to green (full) to show you the level of battery charge. If the light is constant, your UPS is operating from line power,
and the battery is charging. If the light is flashing, your UPS is operating from battery power, and the battery is
discharging. When the light flashes red, close any files you are working on and shut down your computer.
9906059 Direct Plug-In Isobar Owner's Manual FINAL.p65 8/25/00, 10:58 AM2
3
ISOBLOK ISOFAX ULTRABLOK
Outlets: 2 x NEMA 5-15R 2 x NEMA 5-15R 2 x NEMA 5-15R
Dimensions (H x W x D): 4 x 2½ x 2½" 5 x 2½ x 2½" 4 x 2½ x 2½"
ULTRACOAX ULTRACOPY ULTRAFAX
Outlets: 2 x NEMA 5-15R 2 x NEMA 5-20R 2 x NEMA 5-15R
Dimensions (H x W x D): 4 x 2½ x 2½" 4 x 2½ x 2½" 4 x 2½ x 2½"
ALL MODELS:
• UL 1283 Listed (noise reduction)
• ULTRA: UL 1449, 1998 rev. Listed (330V let-through)
• ISO: UL 1449, 1998 rev. Listed (330V let-through H-N, 400V let-through H-G & N-G)
Rated Input Voltage: 105 to 132V AC; 60 Hz; (120V AC nominal)
Energy Absorption: 600 joules
Surge/Spike Protection: 48,000 amps
High Frequency Noise Suppression: > 20db @ 50Khz
> 40db @ 500Khz
> 75db @ 1Mhz
> 30db @ 6-1000Mhz
Transient Response Time: Instantaneous*
* Transient amplitude reduction occurs faster than the clamp response of the varistors because of the high rejection
rate of the ISOBAR filter networks.
COAXIAL CABLE SPIKE PROTECTION (ULTRACOAX MODEL ONLY):
Peak Pulse Power Dissipation: 1500 watts
Energy Absorption: 7 joules
Clamping Voltage: ± 27V
Insertion Loss: Less than 3 db
Circuit Breaker: Fast-acting fuse
Input/Output Connectors: Female 'F' connectors
TELEPHONE LINE SPIKE PROTECTION (ISOFAX AND ULTRAFAX MODELS ONLY):
• UL 497A Listed (secondary communications protection)
Peak Transient Input Voltage: 6Kv, 10 microseconds
Energy Absorption: 140 joules
Response Time: Less than 5 nanoseconds
Clamping Voltage: 200V peak, ±10%
EMI Noise Reduction: Up to 27 db
Input/Output Connectors: ULTRAFAX features female RJ11 jacks; 2-wire, single line protection
ISOFAX features female RJ11/45 jacks; 4-wire, 2-line protection
CONSUMER INFORMATION AND FCC REQUIREMENTS
(FOR ISOFAX AND ULTRAFAX MODELS IN THE U.S. ONLY)
1. This equipment complies with Part 68 of the FCC rules. On the top or bottom of this equipment is a label that contains, among other
information, the FCC registration number for this equipment. If requested, provide this information to your telephone company.
2. If your Fax/Modem Protector causes harm to the telephone network, the Telephone Company may temporarily discontinue your service.
If possible, they will notify you in advance. If advance notice isn't practical, you will be notified as soon as possible. You will be advised of
your right to file a complaint with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation
of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this equipment, Fax/Modem Protector, please contact Tripp Lite Customer Support, 1111 W. 35th Street,
Chicago, Illinois 60609; Phone (773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this
equipment from the network until the problem has been corrected or you are sure that the equipment is not malfunctioning. There are no
repairs that can be made by the customer to the Fax/Modem Protector.
5. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
(Contact your state public utility commission or corporation commission for information.)
Specifications
9906059 Direct Plug-In Isobar Owner's Manual FINAL.p65 8/25/00, 10:58 AM3
4
Warranty & Insurance: p. 6
Lifetime Limited Warranty
TRIPP LITE warrants its products to be free from defects in materials and workmanship for life. TRIPP LITE’s obligation under this warranty is limited to repairing
or replacing (at its sole option) any such defective products. To obtain service under this warranty, you must obtain a Returned Material Authorization (RMA)
number from TRIPP LITE or an authorized TRIPP LITE service center. Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with
transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty
does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way.
The warranties of all TRIPP LITE surge suppressors are null and void if they have been connected to the output of any UPS system. The warranties of all TRIPP
LITE UPS Systems are null and void if a surge suppressor has been connected to its output receptacles.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s)
or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is
not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims
by third parties, or otherwise.
The policy of TRIPP LITE is one of continuous improvement. Specifications are subject to change without notice.
Ultimate Lifetime Insurance Policy
(Valid in U.S. and Canada ONLY)
TRIPP LITE warrants, for the lifetime of the product, (at TRIPP LITE's option) to repair or replace (on a pro rata basis) directly connected equipment that is damaged
due to power transients while properly connected to TRIPP LITE products offering the ULTIMATE
Lifetime Insurance Policy. Reimbursement or restoration for
data loss is not included. Power transients include spikes and surges on the AC power, data or telephone lines that the TRIPP LITE products have been designed
to protect against (as recognized by industry standards).
AC Power Line Transients: To claim damages, the TRIPP LITE product must be plugged into a properly wired and grounded outlet. No extension cords or
other electrical connections may be used. The installation must comply with all applicable electrical and safety codes set forth by the National Electrical Code
(NEC). Except as provided above, this warranty does not cover any damage to properly connected electronic equipment resulting from a cause other than an
"AC power transient." If user meets all of the above requirements, TRIPP LITE will repair or replace (at TRIPP LITE's option) equipment up to the specified value
(See ULTIMATE
Lifetime Insurance Policy Limits). No coverage is allowed for damage entering from telephone or data lines, unless they are separately protected,
as described below.
Coaxial, Telephone and Data Line Transients: Tripp Lite will repair or replace directly connected equipment that is damaged by transients on telephone and/
or data lines
only when all such paths are protected by a Tripp Lite protection product(s) and the AC power (utility) line is simultaneously protected by a Tripp
Lite power protection device (UPS, surge suppressor or line conditioner) with Ultimate Lifetime Insurance coverage. Reimbursement dollar limits will be equal
to that of the Tripp Lite power protection protector. Coverage is excluded where a suitable environment for the protection device is not provided, including,
but not limited to, lack of a proper safety ground. Telephone service equipment must also include a properly installed and operating "primary protection" device
at the telephone service entrance (such devices are normally added during telephone line installation).
All above warranties are null and void if the TRIPP LITE product has been improperly installed, tampered with or altered in any way, or if the connected equipment
was not used under normal operating conditions or in accordance with any labels or instructions. All claims under this warranty must be submitted in writing
to Tripp Lite within 30 days of the occurrence or the claim will not be considered. This warranty does not include damage resulting from accident or misuse,
and applies to the domestic (USA and Canada) use of these products only.
Tripp Lite reserves the right to determine whether the damage to the connected equipment is due to malfunction of the Tripp Lite product by requesting the
equipment in question be sent to Tripp Lite for examination. This policy is above and beyond, only to the extent needed, of that provided by any coverage
of connected equipment provided by other sources, including, but not limited to, any manufacturer's warranty and/or any extended warranties.
EXCEPT AS PROVIDED ABOVE, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s)
or exclusion(s) may not apply to purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is
not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims
by third parties or otherwise.
To receive service under this warranty, you must be the original purchaser/user of the product in question. You must obtain a Returned Material Authorization
(RMA) number from TRIPP LITE. Products must be returned to TRIPP LITE with transportation charges prepaid and must be accompanied by a brief description
of the problem encountered and proof of date and place of purchase.
Warranty and Insurance
9906059 Direct Plug-In Isobar Owner's Manual FINAL.p65 8/25/00, 10:58 AM4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Tripp Lite ULTRACOAX User manual

Category
Surge protectors
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI