OPERATION
Settings and displays
8 | DCE-X Premium www.stiebel-eltron.com
4.9.4 Further information on the parameter menu
P1: ECO water and energy saving function
The ECO function enables you to limit the flow rate to a maximum
value.
ECO level Display
shows
Flow rate limitation
ECO1 6l/min
ECO2 5l/min
ECO3 4l/min
OFF No symbol No flow rate limit
P2: Temperature limit (childproofing)
The temperature limit allows you as a user to restrict the ad-
justable temperature at the appliance to a maximum value. Your
qualified contractor can set an additional temperature limit for
anti-scalding protection. This temperature then dictates the upper
limit of the setting range for the temperature limit function.
P3: Wellness showers
The Wellness shower program lets you choose between 4 differ-
ent hot/cold contrast showers.
WW = warm water, KW = cold water
min = minutes, sec = seconds
Shown in °C
- 1 Cold prevention
To strengthen the body, we recommend finishing off with a cold
shower; this will trigger a reflex in the body to warm up.
WW
KW
3min
- 2 Winter pick-me-up
An invigorating end to a winter shower with a final warm-up.
WW
WW
3 min 10 sec
10 sec
10 sec
10 sec
WW - 10 °C | 50 °F
- 3 Summer fitness program
A quick contrast shower to increase fitness with a final warm-up.
WW
KW
3min
10 sec
10 sec
10 sec
10 sec
- 4 Circulation boost program
Shower your arms and legs with cold water to boost circulation.
Spray from the hands and feet towards the body. You can then
repeat this process with hot water.
WW
KW
3min 30 sec
20 sec
30 sec
20 sec
P4: Automatic water volume control
The automatic water volume control allows you to limit the volume
of water at a high flow rate. When the selected volume of water
is reached, the control automatically reduces the flow rate. The
required temperature is maintained. The automatic water volume
control must be enabled on each occasion prior to filling the bath.
Example, filling a bath with 80litres (21gallons): When the bath
has been filled with 80litres (21gallons) of water, the control
automatically reduces the flow rate to 4l/min (1gpm).
P5: Setting the temperature unit
Select the temperature unit for all settings.
P6: Setting the volume unit
Select the volume unit for all settings.
P7: Setting the time format
Select the time format for all settings.
P8: Setting the time
You can set the time using the 12 or 24hour clock:
- 12hours from 00:00 - 11:59= AM | 11:59 - 00:00= PM
- 24hours from 00:00 to 23:59
After a power cut, the time needs to be set again.
P9: Operating lock
You can set the operating lock to "ON" or "OFF".
To disable the set operating lock:
Press and hold "i" for more than 10seconds.
P10: Resetting to factory settings
In menu item "P13", the appliance can be reset to its factory
settings. "rSEt" is shown on the display.
Press and hold "1" and "2" simultaneously for more than
5seconds. The display switches to "On" to confirm the reset.
To confirm "On", press and hold "i" for more than 5seconds.
P11: Resetting the consumption values
In menu item "P14", the consumption values can be reset. "rSEt"
is shown on the display.
Press and hold "1" and "2" simultaneously for more than
5seconds. The display switches to "On" to confirm the reset.
To confirm "On", press and hold "i" for more than 5seconds.
P12: Adjusting the backlighting
The display backlighting is adjustable.
- The backlighting switches on whenever the appliance is in
heating mode or when the user interface is operated.
- If there is no operation for 30seconds, the backlighting
switches off.
- If you select "On", the backlighting will remain on constantly.
P13: Reduce backlighting
There are 2 brightness levels for the backlighting: 100% | 50%