This brick liner accessory is approved for use in (V)
FB(F,L)(32,36,42) series vent-free reboxes. Do not use
brick liner accessory in any other replace models.
The Brick Liner Kit contains the following:
32" Fiber Panel Kit BLZ32SVF
Description Part No. Qty.
Rear Panel 126242-01 1
Right Side Panel 126241-01 1
Left Side Panel 126240-01 1
Retainer Brackets 116531-01 2
#10 Screws 4
36" Fiber Panel Kit BLZ36SVF
Description Part No. Qty.
Rear Panel 126245-01 1
Right Side Panel 126244-01 1
Left Side Panel 126243-01 1
Retainer Brackets 116531-01 2
#10 Screws 4
42" Fiber Panel Kit BLZ42SVF
Description Part No. Qty.
Rear Panel 126248-01 1
Right Side Panel 126247-01 1
Left Side Panel 126246-01 1
Retainer Brackets 116531-01 2
#10 Screws 4
Figure 1 - Brick Liner Kit
www.fmiproducts.com
Tools required:
• Phillips Screwdriver
• 5/16'' Hex Socket Wrench or Nut Driver
If any of these parts are missing or damaged, contact
the dealer where you purchase this kit. If they cannot
supply original replacement parts, either contact your
nearest Parts Central or call FMI PRODUCTS, LLC at
1-866-328-4537 for information.
Note: Some installations may require the gas supply
line to be disconnected before removing log assembly.
If so, call a qualied service person to disconnect gas
supply from replace.
IMPORTANT:Alwayshandlerebrickpanelswithtwohands.
WARNING: Turn off, unplug, and let replace cool
before installing brick liner. Only a qualied service
person should service and repair replace.
NOTICE: If already installed, you must remove log base
assembly before installing brick liner. Refer to log base
assembly owner's manual.
WARNING: A qualied service person must con-
nect and disconnect replace to gas supply. Follow
all local codes.
Screws
Screws
Retaining
Bracket
Retaining
Bracket
Left Side
Panel
Right Side
Panel
Rear Panel
Gas Line
Knockout
126389-01
Rev. A
10/12
Figure 2 - Firebrick Panels with Retaining Brackets and Gas Knockout
1. Installrearrebrickpanelonbackwall.Restbottom
edgeofrebrickpanelonreboxoor.Leanrebrick
againstbackwallofreboxwhileinstallingsidepanels.
Note: The rear panel is held in place by two side panels.
2. Gentlyslideleftsidebrickintoplacewhileholdingrear
brickpaneluprightagainstreboxback.
3. Usesuppliedretainerbracketandscrewtosecureside
brickpaneltorebox(seeFigure2).
4. Repeatsteps2and3forrightsidebrickpanel.
CAUTION: Always handle ber panels with two
hands. Do not force ber panels into place. Exces-
sive force will break ber panels.
5. There is a gas knockout in each side panel for the
gaslinetofeedthrough(seeFigure2).Determineon
whichsidethegasconnectionwillbelocated.Usinga
utilityknifeorcuttingblade,removetheidentiedgas
knockout.
6. Replace log base if removed for rebrick installation
(seelogbaseowner'smanualforproperinstallation).
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct all leaks
at once.
WARNING: Never use an open ame to check for
a leak. Apply a noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
Screws
Retaining
Bracket
Retaining
Bracket
Gas
Knockout
2701S.HarborBlvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
  • Page 1 1
  • Page 2 2

FMI BLZ32SVF Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI