FMI G8007 Operating instructions

Category
Wall & ceiling mounts accessories
Type
Operating instructions

FMI G8007 is a brick liner kit designed for use in VSGF36 series vent-free gas fireplaces. It contains a rear firebrick panel, two side firebrick panels, two retainer brackets, and two screws. The kit is easy to install and can be completed in just a few steps.

The brick liner kit helps to protect the fireplace from heat damage and provides a more realistic look. It is also easy to clean and maintain.

Here are some of the benefits of using the FMI G8007 brick liner kit:

  • Protects the fireplace from heat damage
  • Provides a more realistic look
  • Easy to clean and maintain
  • Can be installed in just a few steps

FMI G8007 is a brick liner kit designed for use in VSGF36 series vent-free gas fireplaces. It contains a rear firebrick panel, two side firebrick panels, two retainer brackets, and two screws. The kit is easy to install and can be completed in just a few steps.

The brick liner kit helps to protect the fireplace from heat damage and provides a more realistic look. It is also easy to clean and maintain.

Here are some of the benefits of using the FMI G8007 brick liner kit:

  • Protects the fireplace from heat damage
  • Provides a more realistic look
  • Easy to clean and maintain
  • Can be installed in just a few steps
IMPORTANT: Read entire instruction sheet before install-
ing brick liner.
This brick liner accessory is approved for use in VSGF36
series vent-free gas fireplace systems. Do not use brick
liner accessory in any other fireplace models.
The Brick Liner Kit contains the following:
1 - Rear Firebrick Panel
2 - Side Firebrick Panels
2 - Retainer Brackets
2 - #10 Screws
Tools required:
Phillips Screwdriver
5/16" Hex Socket Wrench or Nut Driver
If any of these parts are missing or damaged, contact dealer where
you purchased this kit. If they cannot supply original replacement
parts, either contact your nearest Parts Central or call DESA Inter
-
national at 1-866-672-6040 for information.
IMPORTANT:
Always handle firebrick panels with two hands.
WARNING: Turn off, unplug, and let fireplace cool
before installing brick liner. Only a qualified service
person should service and repair fireplace.
NOTICE: You must remove log base assembly before
installing brick liner.
1. To remove screen, lift screen up off the screws in front of
fireplace (see Figure 1).
Figure 1 - Removing Fireplace Screen
Screws for
Mounting
Screen
www.desatech.com
G8007 SERIES BRICK LINER KIT
INSTALLATION INSTRUCTIONS
www.desatech.com
114421-01B
2
2. Remove logs. Remove four screws that attach log base assembly
to fireplace. Carefully lift log base assembly and remove from
fireplace (see Figure 2).
CAUTION: Do not pick up log base assembly by
burners. This may damage burners. Only pick up
base by the grate.
Note: Some installations may require the gas supply line to be
disconnected before removing log assembly. If so, call a quali-
fied service person to disconnect gas supply from fireplace.
WARNING: A qualified service person must con-
nect and disconnect fireplace to gas supply. Follow
all local codes.
3. With larger bricks at the top, install rear firebrick panel on back
wall first. Rest the bottom edge of firebrick panel on liner flange.
Stand firebrick panel straight up against the back of fireplace
(see Figure 3). Note: Side brick liners will hold rear firebrick
in place.
CAUTION: Always handle firebrick panels with
two hands. Do not force firebrick panels into place.
Excessive force will break firebrick panels.
4. With larger brick at top of panel, slide one side firebrick panel
behind the retaining edge of fireplace. Gently press the firebrick
panel back against the side wall (see Figure 4). The bottom edge
of the firebrick panel will rest on liner flange.
CAUTION: Always handle firebrick panels with
two hands. Do not force firebrick panels into place.
Excessive force will break firebrick panels.
Figure 4 - Placing Side Firebrick Panel Behind Retaining
Edge
Liner Flange
Larger
Brick at
Top of
Panel
Side
Firebrick
Panel
Side Wall
Retaining
Edge
Figure 2 - Removing Log Base Assembly from Fireplace
Figure 3 - Placing Rear Firebrick Panel on Flange in Fireplace
Burners
Screws
Log Base
Assembly
Liner Flange
Larger Brick at
Top of Panel
Rear
Firebrick Panel
Screws
www.desatech.com
114421-01B
3
6. Secure side firebrick panel to side wall of fireplace with one
retainer bracket and one screw (see Figure 5).
Note: If there is a screw in the fireplace side walls where you
are to install the retaining bracket, remove screw.
7. Repeat steps 5 and 6 to install other side of firebrick panel.
8. Put log base assembly back into fireplace. Secure log base as-
sembly with the four screws removed in step 2 (see Figure 2,
page 2).
WARNING: A qualified service person must con-
nect and disconnect fireplace to gas supply. Follow
all local codes.
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct all leaks
at once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
9. Replace logs. Make sure logs are put in their proper position.
See Installing Logs in the Fireplace Owners Manual.
10. Replace screen (see Figure 1, page 1).
Figure 5 - Securing Side Firebrick Panel to Side Wall of
Fireplace
Retaining
Edge
Screw
Retainer Bracket
114421-01
Rev. B
01/05
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
Technical Service Department 1-866-672-6040
114421 01
NOT A UPC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

FMI G8007 Operating instructions

Category
Wall & ceiling mounts accessories
Type
Operating instructions

FMI G8007 is a brick liner kit designed for use in VSGF36 series vent-free gas fireplaces. It contains a rear firebrick panel, two side firebrick panels, two retainer brackets, and two screws. The kit is easy to install and can be completed in just a few steps.

The brick liner kit helps to protect the fireplace from heat damage and provides a more realistic look. It is also easy to clean and maintain.

Here are some of the benefits of using the FMI G8007 brick liner kit:

  • Protects the fireplace from heat damage
  • Provides a more realistic look
  • Easy to clean and maintain
  • Can be installed in just a few steps

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI