0800 (Domestic U.S. & Canada)
16842 Millikan Avenue, Irvine CA 92606 Tel: 1-949-261-2999 (California and International) Fax: 1-949-261-7326
Mi-SLI 762FP-ISS_0912.docx
SECO-LARM
(optional)
+12VDC
Ignition Coil
(White tube, Circuit 2)
Switched
+12VDC
Ignition (Purple label)
Starter Solenoid
(Red tube, Circuit 1)
Spare Armed Output to cut fuel pump
(Brown label, circuit 3)
30
85
86
87
87a
NOTE: This wire must
show +12V when the
ignition switch is in the
ON and START position.
+12VDC (Red label)
Ground (Black label)
Ground (Black label)
®
®®
®
Spare, Armed output to cut fuel pump
(Brown label, Circuit 3)
Find the wire that runs the fuel pump and is +12VDC
while the engine is starting or running, but 0VDC when
the engine is off. Cut this wire. At this time, the engine
should be able to turn over but NOT start. Connect the
two ends of the cut wire and the Circuit 3 wire with an
optional heavy-duty automotive relay as shown in the
diagram on the left.
Ignition coil (White tube, Circuit 2)
Find the wire that runs the ignition coil and is +12VDC
while the engine is starting and running, but 0VDC when
the engine is off. Cut this wire. At this time, the engine
should be able to turn over but NOT start. Connect one
end of the cut wire to one of the Circuit 2 wire pairs and
the other end to the second pair of wires. Connection is
non-polar.
Starter solenoid (Red tube, Circuit 1)
Find the wire that runs to the starter solenoid and is
+12VDC only while the engine is being started. Make
sure the vehicle is in park or neutral. Cut this wire. At
this time, the engine should NOT be able to turn over or
start. Connect one end of the cut wire to one of the
Circuit 1 wire pairs and the other end to the second pair
of wires. Connection is non-polar.
2x Ground (Black label)
Connect to chassis ground. For the best long-term
reliability, ground the Immobilizer to the chassis using a
factory bolt. If not possible, ground to the chassis with a
metal screw and star washer.
WIRES
LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) ye
ar from the date of sale to the original
consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if
for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any
special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
The information and specifications printed in this manual are current at the time of publication. However, the SECO
LARM policy is one of continual development and improvement. For
this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2009 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
+12VDC (Red label)
Connect to a source of constant +12VDC.
Ignition (Purple label)
Connect to a wire or fuse that is +12VDC when the
ignition key is in the ON and START positions, but not
when the ignition key is in the ACC position or OFF.
MUST HAVE POWER AT ALL TIMES WHILE THE
ENGINE IS CRANKING FOR CORRECT OPERATION.