Slant/Fin S-60 User manual

Type
User manual
SENTRY
©Slant/Fin Corp. 2007
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
DIMENSIONS – GAS BOILERS
®
C
19
3
/
4
"
19
3
/
4
"
19
3
/
4
"
1
1
/
2
"
Supply
1
1
/
2
"
Supply
1
1
/
2
"
Supply
3
/
4
"
Drain
3
/
4
"
Drain
3
/
4
"
Drain
3
/
4"
to air eliminating
system (by others)
3
/
4"
to air eliminating
system (by others)
3
/
4"
to air eliminating
system (by others)
Rollout Safety
Switch
(behind
front panel)
R
ollout Safety
S
witch
(behind
front panel)
Rollout Safety
Switch
(behind
front panel)
Vent Damper*
V
ent Damper*
V
ent Damper*
Vent Damper*
28
7
/
16
"
28
7
/
16
"
32
7
/
16
"
6
1
/
2
"
Pressure/Temp.
Gauge
Pressure/Temp.
G
auge
High Limit.
C
ontrol
Ignition
C
ontrol
H
igh Limit
Control
Ignition
Control
High Limit
Control
Ignition
Control
B
locked Vent
S
afety Switch
B
locked Vent
Safety Switch
Blocked Vent
Safety Switch
Supply Piping
(by others)
Supply Piping
(by others)
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
C
ombination
G
as Valve
(
gas tapping 1/2")
Ground
Joint Union
Ground
Joint Union
Ground
Joint Union
C
irculator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
C
irculator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
S
ediment Trap
(required)
Sediment Trap
(required)
Sediment Trap
(required)
(
Dotted piping
by others.)
(Dotted piping
by others.)
(Dotted piping
by others.)
I
ntegral 
Draft
Diverter
Pressure/Temp.
Gauge
C
A
B
C
A
A
B
B
C
D
Dimensions
MODELS S-60
to S-150
Dimensions
MODEL S-34
Dimensions
MODELS SX-150
to SX-210
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
*Vent damper may be installed horizontally on all models with use of a common vent elbow.
S-34 8
1
8 14
5
8 4__
S-60 11
1
8 17
5
8 4__
S-90 14
1
8 20
5
8 5_ _
S-120 17
1
8 23
5
8 6__
S-150 20
1
8 26
5
8 7__
SX-150 20
1
8 26
5
8 _647
SX-180 23
1
8 29
5
8 _748
3
16
SX-210 26
1
8 32
5
8 _748
3
16
MODEL
NUMBER
DIMENSIONS-Inches
A
B
D
C-VENT
DIAMETER
INTEGRAL
DRAFT
DIVERTER
EXTERNAL
DRAFT
HOOD
  • Page 1 1

Slant/Fin S-60 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI