Technical Bulletin
Identification:
Bulletin no:
Date:
Issuer:
Factory:
E01
VT2006-01
15-02-2006
Customer Support Dept.
Pordenone (Italy)
ELECTROLUX PROFESSIONAL p. 1 of 2
Subject:
NEW COOLING UNIT BASEMENT
Model:
Heavy Duty cabinets 1400 L (2 doors).
Problem:
The condensed water doesn’t flow into the evaporation basin, but
drops out the tile across the front panel and the frames.
Reason: Bad alignment between the tile and the water outlet of the
evaporator basement.
Action in
Factory:
The new basement is in production starting from week 3/2006.
Action in
Field:
In case of water leakage on appliance with the old basement:
make an extra seal all around the tile with silicon (as shown in the picture
on page 2
).
The new design of the basement tile: