  • Hello! I am an AI chatbot trained to assist you with the Electrolux 726321 (RS13RX2F) Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Technical Bulletin
Identification:
Bulletin no:
Date:
Issuer:
Factory:
E01-02-03-06-07-09
VTX2005-02
21-03-05
Customer Support Dept.
Pordenone (Italy)
ELECTROLUX PROFESSIONAL p. 1 of 2
VIALE TREVISO, 15 – 33170 PORDENONE – ITALY
TELEPHONE: TELEFAX: E-MAIL:
+ 39 0434 380 737 + 39 0434 380 740 [email protected]t
Subject:
NEW EVAPORATOR PROBES
Model:
Cabinets & Counters, Roll-in, BC-BCF
Problem:
High rate of fully functional replaced parts
Reason:
High sensitiveness to mechanical stress and humidity
Action in
Factory:
Starting from week 11 2005 a new evaporator probe is used in all
above mentioned ranges
Action in
Field:
Since the new evaporator probe can be retrofitted also on
previous models, in case of probe failure follow this procedure:
A. Heavy Duty, Prostore, Roll-in cabinets with SMART electronics:
Replace the evaporator probe looking in the spare parts
catalogue for the new probe (in the “notes” field you will
find written “starting from w11 2005”)
After the replacement, enter in the parameter list of the
appliance and change the parameter TEAP from NTC2 to
NTC3.
B.
Heavy Duty, Prostore, Roll-in cabinets with digital control & all
counters:
Replace the evaporator probe looking in the spare parts
catalogue for the new probe (in the “notes” field you will
find written “starting from w11 2005”)
Technical Bulletin
Identification:
Bulletin no:
Date:
Issuer:
Factory:
E01-02-03-06-07-09
VTX2005-02
21-03-05
Customer Support Dept.
Pordenone (Italy)
ELECTROLUX PROFESSIONAL p. 2 of 2
Technical specifications:
New evaporator probe
Protection cover in stainless steel A304
IP index 68
NTC 10K Semitek made with SMD technology
Accuracy 1%
Old evaporator probe
099570 Length 2000 mm
099659 Length 2000 mm
099658 Length 1500 mm
099657 Length 1500 mm
099660 Length 3000 mm
099683 Length 4000 mm
099722 Length 4000 mm
VIALE TREVISO, 15 – 33170 PORDENONE – ITALY
TELEPHONE: TELEFAX: E-MAIL:
+ 39 0434 380 737 + 39 0434 380 740 [email protected]t
/