Haier DE65EM-TC User manual

Type
User manual

This manual is also suitable for

2014
DE45EM
DE45EM-T
DE45EM-TC
DE45EM-E
DE65EM
DE65EM-T
DE65EM-TC
DE65EM-E
AC1011S004V0
All manuals and user guides at all-guides.com
all-guides.com
8
0
1
3
All manuals and user guides at all-guides.com
M
All manuals and user guides at all-guides.com
45 Prints
180/150
57/56
11
15
R410A/7.4Oz
4.2
480 690
21
13 3/8
10 5/8
22 1/2
14 3/4
12
16.8
18.6
17.7
18.6
910
740
14
16 1/2
25 3/16
12
15
23 1/2
6.2
R410A/8.1Oz
57/56
220/200
65 Prints
Unit Dimensions
1.85
1.85
All manuals and user guides at all-guides.com
3
All manuals and user guides at all-guides.com
NO other extension cord is permitted.
All manuals and user guides at all-guides.com
all-guides.com
1.Remove the plastic cap at the
rear of the unit.(Keep the rubber
insert well for use later.)(Fig.#1)
2.Tightly screw the purchased
garden hose to the direct drain
opening.(Fig.#2)
3.Position the dehumidifier as close
as you can to the floor drain.
5.When the direct drain feature is
not being used,remove the drain
hose from the direct drain opening
and plug it with the rubber cap
provided.
4.Position the opening end of the
drain hose directly over the floor
drain and start the unit.
All manuals and user guides at all-guides.com
All manuals and user guides at all-guides.com
8
Bucket Full Indicator
When the indicator light comes on, automatic flow
control stops the unit.
Turn the unit off by pressing the POWER key.
Check to see if the bucket is full. If so, empty it.
If bucket is not full and indicator light is on, the
bucket is not in the proper position. Remove and
reinstall it.
Hr
CURRENT
HUMIDITY
SET
HUMIDITY
34
5
6
7
8
9
10
Check Filter Indicator
The "check filter" indicator will flash when the
filter needs to be cleaned. Remove the filter,
wash it, and put it back in. Press "Filter Reset."
The "check filter" indicator will turn off.
Note: Make sure the filter is dry before replacing.
6
Smart Dry
This setting compares the set humidity level with
the actual humidity level and adjusts the fan
speed automatically.
7 Signal
The bucket full audible signal can be turned on
and off by pressing the SIGNAL button. The
default setting is set in the ON position. When
the bucket is full, the red BUCKET FULL indicator
light will blink and the alarm will sound 5 times
every 15 minutes.
To turn off the audible signal feature, press the
SIGNAL button once, and the LED display will
show “OF” for 2 seconds. In this setting, when
the bucket is full, the BUCKET FULL indicator light
will blink, but the audible alarm will not sound.
To reactivate the audible signal, press the
SIGNAL button and the LED display to the left
will show “ON” for 2 seconds.
5
Power
2
10
Current Humidity/Setting Humidity Display
Displays the current humidity level and adjusts the
humidity to a desired level.
Setting Humidity Range: 40%RH~70%RH
Display Humidity Range: (LO)30%RH~(HI)90%RH
9
Current Temp/Timer Set Display
When the dehumidifier is running,it displays the
current temperature.Press the timer key to program
the dehumidifier to turn on or off automatically at a
pre-deter mined time.
All manuals and user guides at all-guides.com
8
All manuals and user guides at all-guides.com
9
All manuals and user guides at all-guides.com
all-guides.com
0
dehumidify
evaporator
condenser
All manuals and user guides at all-guides.com
+5V
Humidity
E1
100uF-16V
LED3
BUZZ1
KPMG09C1-3031
LED4
LED5
LED6
LED7
LED8
3
3
3
3
3
3
3
LED9
C10
0.1uF
+5V
1B
1
2B
2
3B
3
4B
4
5B
5
6B
6
7B
7
E
8
COM
9
7C
10
6C
11
5C
12
4C
13
3C
14
2C
15
1C
16
IC2
+5V
C17
0.1uF
C1
0.1uF
N1
8050
+
5V
C8
0.1uF
+5V
SW2
TSTC-2L
6*6*5
SW3
TSTC-2L
6*6*5
SW4
TSTC-2L
6*6*5
SW5
TSTC-2L
6*6*5
SW6
TSTC-2L
6*6*5
SW7
TSTC-2L
6*6*5
SW1
TSTC-2L
6*6*5
+5V
C11
0.001uF
1
2
3
4
5
6
7
8
9
01
CN1
S10B-PH
C3
0.1uF
C4
0.1uF
C5
0.1uF
C2
0.1uF
C6
0.1uF
+5V
TXD
RXD
+5V
+5V
GND
C18
0.01uF
1
2
3
4
CN20
5267-04A
+5V
1
2
3
4
56
7
8
9
01
LED1
ZN013
1
2
3
4
56
7
8
9
01
LED2
ZN013
IRQ
1
PTA0
2
VSS
3
OSC1
4
OSC2
5
PTA1
6
VDD
7
PTB4/ADC4
17
PTA2
8
PTA3
9
PTB7/ADC7
10
PTB6/ADC6
11
PTB5/ADC5
12
PTD7/RXD
13
PTD6/TXD
14
PTE0/T2CH0
15
PTE1/T2CH1
16
PTD0/ADC11
18
PTB3/ADC3
19
PTB2/ADC2
20
PTD1/ADC10
21
PTB1/ADC1
22
PTB0/ADC0
23
PTD3/ADC8
24
PTA4
25
PTD2/ADC9
26
PTD5/T1CH1
27
PTD4/T1CH0
28
PTA5
29
RST
30
PTA7
31
ADC12
32
IC1
MC68HC908JL8CSPE-SDIP32
+5V
C7
0.1uF
+5V
+5V
P I P E
H U M I D I T Y
R O O M
C O M P
L O W
H I
V A L V E
F U L L
V5
DNG
1
2
CN23
TJC8-2
DATA
OSC1
IRQGND
+5V
SMART HI LOW T_ON T_OFF FULL FLTER
SIGNAL SPEED TIMER UP DOWN FLTER RESET POWER
Temp/Timer
C30
0.1uF
A0
1
A1
2
A2
3
VSS
4
SDA
5
SCL
6
TEST
7
VCC
8
IC5 AT24C02B-DIP8
R1
100Ω
R7
1K
R38
4.7K
R26
10K
R44
1M
R4
2K
R68
10K
R29
10K
R5
2K
P1
2SA1037AK
21R
K1
11R
K1
8R
K1
54R
K1
01R
K1
82R
K1
31R
K1
72R
K1
R46
3.3 K
R9
3 .3 K
R61
3.3 K
R15
1 0K
R14
1 0K
R16
1 0K
R17
1 0K
R20
1 K
R19
1 K
R18
1 K
R63
3.3 K
R53
330Ω
R52
330Ω
R47
330Ω
R48
330Ω
R49
330Ω
R50
330Ω
R51
330Ω
R39
4.7K
R40
4.7K
R30
10K
R31
10K
R32
10K
R33
10K
R41
4.7K
R42
4.7K
R43
4.7K
R70
10K
P2
8550
P3
8550
P4
8550
P5
8550
P6
8550
R21
1K
R65
1K±1
R60
1K±1
R57
1.5K±1
R6
1.5K±1
R56
2K±1
R55
3K±1
R66
3.9K±1
R59
8.2K±1
R58
8.2K±1
R54
560Ω
R69
10K
R35
10K
R71
10K
R67
1K
R3
100Ω
R2
100Ω
1
2
CN24
TJC8-2
1
2
CN25
TJC8-2
XT1
MPP03±M2519.4
C21
30pF
C19
30pF
R64
10K
+5V
E3
100uF-16V
TVS1
HTVSB7.0CA-100
11
All manuals and user guides at all-guides.com
+12V
K1
892N-1AC-C(AC250V-5A)
K3
892N-1AC-C(AC250V-5A)
K2
892N-1AC-C(AC250V-5A)
+12V
K4
891WP-1A-C(AC250V-25A)
+5V
E9
100uF-25V
C12
0.1uF
R36
1K
R23
1K
C24
0.1uF
R22
10K
FULL
VALVE
E8
4.7uF-50V
COMP N
HI
LOW
R37
1K
1
2
CN4
B 2 B - X H
+5V
P I P E
R25
5.1K
R34
1K
uF-50
V
1
2
CN2
B 2 B - X H
+5V
R O O M
R24
5.1K
E7
4.7uF-50V
+5V
16
15
3 14
4 13
5 12
O6
O7
I2
I3
I5
I6
11
O2
O4
O5
I1
I4
I7
O1
O3
7
6
10
COM
9
GND
8
1
2
IC3 ULN2003-SOP16
CN5
D187(8A)
CN6
D187(8A)
1
2
3
4
5
6
7
8
9
01
CON1
480mm-10-B10B-PH
+5V
R
C
RC1
300V-120Ω-103
R
C
RC2
300V-120Ω-103
1
CN9
D250(10A)
1
CN10
D187(8A)
1
1
CN8
D187(8A)
1
CN7
D187(8A)
P I P E
H U M I D I T Y
R O O M
C O M P
L O W
H I
V A L V E
F U L L
V5
GND
1
2
3
CN3
4 0 0 m m - 3 - B 3 B - X H
HUMIDITY
1 2 3 4 5 6 7 8 9 10
C13
0.1uF
C16
0.1uF
C15
0.1uF
C14
0.1uF
+12V
E5
220uF-25V
C9
0.1uF
C20
0.1uF
Vin
1
DNG
2
Vout
3
IC4
MC7805(1A-5V)
E2
2200uF-35V
D4 1N4007
D3 1N4007
D2
1N4007
D5
1N4007
T1
BCY-4-01BK(12V-300mA-115Vac)
RV1
TVR 14561*-560V
CX1
0.1uF-275Vac
FUSE1
T3.15A/250VAC
L
N
+5V
CN11
250
12
All manuals and user guides at all-guides.com
NOTE:
THE PART MAY NOT BE USED.
1 BECAUSE OF DIFFERENT COMPRESSOR
G: GREEN
250VAC
T3.15A
B
BL
R
4
CAPACITOR
FAN MOTOR
L
H
COMPRESSOR
S
R
PROTECTOR
HEAT
C
TRANSFORMER
FUSE1
BL: BLUE
BR: BROWN
B: BLACK
Y: YELLOW
W: WHITE
R: RED
WIRING DIAGRAM
ROOM
SENSOR
PIPETEMP.
SENSOR
W
CN2 CN4
NO
C
SWITCH
FLOAT
W(BL)
BL
B
BL
BL
R
(
0
R
)
CN8
CN7
CN11
CON1
CN1
TEMP.
HI
LOW
3
CN6
CN5
DCF
CN10
N
B(BR)
G(Y/G)
CONTROL
BOARD
1
1
2
2 BECAUSE OF DIFFERENT MODELS
THE PART MAY NOT BE USED.
0010512580
NC
HERM
FAN
C
W
M
M
M
Y
2
CN3
SENSOR
HUMIDITY
B
13
All manuals and user guides at all-guides.com
The End
Domestic Air Conditioner
Sincere Forever
Haier Group
Haier Industrial Park, No.1, Haier Road
Edited by: GuanLi
DingCheng
266101, Qingdao, China
Signed by:
WangRuoFeng
Tel: +86 532 88936935
Approved by: ZhangPeng
Http://www.haier.com
All manuals and user guides at all-guides.com
all-guides.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Haier DE65EM-TC User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI