1891b-enu_1_5_bedingt.fm, 28.08.2015 P1906BA/EN 2015-09 15
Product description 3
Press the start button on the tool; this activates the barcode scanner.
The successful scan is acknowledged by an acoustic signal.
Press the start button on the tool again; this starts the rundown.
Alternatively: assign the Read barcode function to the left function key <F1> on the tool.
Press the left function key <F1> on the tool once.
Press the start button on the tool again; this activates the barcode scanner.
Programming the barcode scanner is described in the programming manual of the control.
3.2.11 Wireless interface
Depending on the exact type, the tools are also equipped with a wireless interface in addition to the IrDA
interface.
The tool uses this wireless interface port for continuous communication with the controller. This interface
port is used to transmit both the parameters and the rundown results. Data transmission is possible in the
Active, Energy saver mode and Standby operating modes, but not possible in Sleep (see 6.2 Operating sta-
tus, page 21). Programming and setting up the wireless interface port are described in the programming
manual of the controller.
3.2.12 LiveWire Memory Chip (LMC)
To permit simple replacement of tools in production, a replaceable LMC memory module is installed. When
the tool is switched on, the network settings are read from the LMC chip and used to establish the WLAN
connection. When the tools are changed, the LMC has to be installed in the new tool being used. Please
refer to 5.4 Changing LMC, page 19.
The following data are stored on LMC:
The MAC address is defined by Cleco and cannot be changed. The other data can be changed via infrared
connection of the tool to the controller .
3.2.13 Platform, only for models of the 47BAYP(…) series
Tools with a platform are basic tools which can be fitted with different add-on parts. Scanners and tags can
be ordered individually.
Type Communications Required linking terminal
47BAW(…)DC
47BAYPB(…)P3
L
WLAN standard IEEE 802.11a/b/g Access point to standard IEEE 802.11a/b/g
After the tool is switched on, it can take up to 35 seconds until the communication is active.
• MAC address • Use of the DHCP server • Country-specific settings
• Network name (SSID) • IP address
• Encryption • Subnet mask
• Network key • Gateway