The gefran R-TC8 is an 8-channel temperature input module with 16 optically isolated digital outputs. It can accept inputs from thermocouples, RTDs, and voltage sources. The module can be configured via software to suit a variety of applications, including temperature monitoring and control. The R-TC8 is ideal for use in industrial environments, such as factories and warehouses. It is also suitable for use in food and beverage processing, as well as in the pharmaceutical industry. Some of its features are:

  • Easy installation and configuration
  • High accuracy and reliability
  • Wide range of input types

The gefran R-TC8 is an 8-channel temperature input module with 16 optically isolated digital outputs. It can accept inputs from thermocouples, RTDs, and voltage sources. The module can be configured via software to suit a variety of applications, including temperature monitoring and control. The R-TC8 is ideal for use in industrial environments, such as factories and warehouses. It is also suitable for use in food and beverage processing, as well as in the pharmaceutical industry. Some of its features are:

  • Easy installation and configuration
  • High accuracy and reliability
  • Wide range of input types
R-TC8
MODULE 8 TEMPERATURE LOOPS
cod. 80131D / Edit 05 -11/09 -ENG
INSTALLATION AND OPERATION MANUAL
2 • INSTALLATION AND CONNECTION
This section contains the instructions necessary for correct
installation of the GILOGIK II into the machine control panel
or the host system and for correct connection of the system
power supply, inputs, outputs and interfaces.
Before proceeding with installation read the following
warnings carefully!
Remember that lack of observation of these warnings
could lead to problems of electrical safety and electroma-
gnetic compatibility, as well as invalidating the warranty.
Qualified staff
the installation and use of the system and components are only reserved
at qualified staff.
Conform use
the system and relative components are usable exclusively to the use
previewed in the manual
In order to guarantee a correct and sure operation are indispensable that
the product comes transported, stored correctly, installed, and controlled
second the previewed modalities.
Suitable for use in pollution degree 2 environment.
Open type equipment.
Notes Concerning Electrical Safety and Electromagnetic
Compatibility:
CE MARKING: EMC Conformity (electromagnetic compatibility)
in accordance with EEC Directive 2004/108/CE.
The GILOGIK II system is mainly designed to operate in industrial
environments, installed on the switchboards or control panels of
productive process machines or plants.
Norm of applicable product EN 61131-2
The Declaration of conformity is available on GEFRAN web:
www.gefran.com
UL listed standard: UL508 file E198546
BT Conformity (low tension)
in accordance with Directive LVD 2006/95/CE.
Advice for Correct Installation for EMC
Inputs and outputs connection
The externally connected circuits must be doubly isolated.
To connect the analogue inputs the following is necessary:
- physically separate the input cables from those of the power supply, the
outputs and the power connections.
- use woven and screened cables, with the screen earthed in one point
only.
GEFRAN S.p.A. declines all responsibility for any damage
to persons or property caused by tampering, neglect,
improper use or any use which does not conform to the
characteristics of the controller and to the indications
given in these Instructions for Use.
I1 • MAIN FEATURES
8 optically isolated inputs for thermocouple, 2 of which are configurable
as input for PT100 resistance thermometers
Thermocouples type J, K, N, R, S, E, L, T
16 isolated digital outputs 24Vdc ± 25%
Protection against polarity inversion, overload, and overheating.
1 optically isolated frequency input 1,5kHz
Software configuration of TC inputs
Diagnostics LEDs for power supplies, outputs, and alarm
Removable connector supplied
1
80131D_MHW_R-TC8_1109_ENG
Inputs
Analogue inputs:
8 optically isolated analogue inputs with:
- 24 bit A/D conversion
- 20 Hz pass band
- input impedance > 1M,
- accuracy exceeding 0.5%
- acquisition frequency for 8 temperatures / channels: 200ms max.
- Input isolation up to 2 kV
The inputs are software configurable as follows:
Input for thermocouples:
- Available on 8 channels
- Thermocouple type selectable via software
- TC J, (0.0 ...1000.0°C/1830.0°F)
- TC K, (0.0 ... 1300.0°C/2372.0°F)
- TC N, (0.0 ... 1300.0°C/2372.0°F)
- TC R, (0.0 ... 1750.0°C/3182.0°F)
- TC S, (0.0 ... 1750.0°C/3182.0°F)
- TC E, (-100.0 ... 750.0°C/190.0°F)
- TC L, (0.0 ... 800.0°C/1472.0°F)
- TC T, (-200.0 ... 400.0°C/752.0°F)
- Integrated room temperature compensation
- Temperatures supplied in tenths of a degree
Input for PT100 resistance thermometers:
- Available on 2 channels
- Resistance thermometer type selectable via software
- RTD type PT100 2 wires, (-200.0 ... 850.0°C / 1562.0°F)
- RTD type PT100 3-4 wires, (-200.0 ... 850.0°C / 1562.0°F)
Input 0…50mV:
- Available on 8 channels
Input 0…2V:
- Available on 8 channels
Digital Inputs
Digital input to measure period and frequency
Input power supply: 24Vdc ± 25%
Maximum input voltage 32Vdc, 25mA
Protection against inversion of polarity
Input trigger:
- maximum voltage for “0” (input OFF) = 12Vdc
- minimum voltage for “1” (input ON) = 15Vdc
1,5kHz input filter
Value supplied in RPM
Digital input isolation up to 2kV
Digital Outputs
24Vdc ± 25% optically isolated digital outputs
- Organization: 1 group of 16 outputs
- Maximum voltage for outputs 32 V
- Maximum current for output 2 A
- Maximum total current 6 A
- Maximum total current of 4 outputs: 4A
group 1: outputs 1, 2, 3, 4
group 2: outputs 5, 6, 7, 8
group 3: outputs 9, 10, 11,12
group 4: outputs 13, 14, 15, 16)
• Outputs protected against overload and overheating.
• Protection trips with current > 2.2A
• Digital output isolation up to 2kV
Over-voltage on inputs and outputs for 1 ms maximum: max. 1kV
Power supply via backplane
R-BUS(x) 3.3V
Diagnostics
- Yellow LED presence 24V external power supplies
- Green LED digital outputs
- Green LED digital input
- Red LED alarm
- Green LED flashing
- low frequency: works with default parameters
- high frequency: works with parameters set by master
MECHANICAL DATA
Dimensions: 92x90x25.4 mm
Weight: 130 g. max
Attachment: snaps onto R-BUS(x)
Connector: 36 pins with spring tightening
AMBIENT CONDITIONS
Working temperature: 0...50°C
Storage temperature: -20...70°C
Humidity: max. 90% Rh not condensing
For UL: Maximum surrounding air temperature 50°C
CONFIGURABILITY OF INPUTS
I3 • TECHNICAL DATA
Input TC
J,K,N,R,S,E,L,T Input
RTD 2-wires Input
RTD 3/4-wires Input
0...50mV Input
0…2V
Channel 1 xx
Channel 2 xx
Channel 3 xx
Channel 4 xx
Channel 5 x
Channel 6 x - (*)
Channel 7 √√√√
Channel 8 x - (*)
(*) = Channel disabled if RTD 3-4 wires is selected on previous channel
x = Channel can be used in any configuration other than RTD
280131D_MHW_R-TC8_1109_ENG
3
80131D_MHW_R-TC8_1109_ITA
4 • INSTALLATION AND CONNECTIONS
The connections of the module call for:
External power supplies:
• 24Vdc ±25% 200mA max.plus the current needed to load the outputs. Use unipolar cable with max section 1 mm2.
Do not attach lug.
• Potentiometer:
use 3-pole shielded cable with max section 0.5 mm2. Do not attach lug. Connect shield directly to ground plate and as close as
possible to the module.
• Thermocouple:
In case of isolated thermocouples, ground the negative pole of the input as close as possible to the module. Do not attach lug.
• Linear analog input:
use 2-pole shielded cable with max section 0.5 mm2. Do not attach lug. Connect shield directly to ground plate and as close as
possible to the module.
• Digital outputs:
use cable with max section 0,5mm2, Do not attach lug
NOTE:
The shield of the analog inputs / outputs must be connected near the module and directly to the ground plate.
19
20
10
17
18
15
16
14
13
12
11
6
8
9
7
4
5
2
3
1
8
AI
T
.C. + 16 DO 24VDC 2A
R-TC8
12
43
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
1
3
5
7
4
6
8
90
1
12
11
34
11
56
11
78
11
90
12
12
22
34
22
56
22
78
22
90
23
12
33
34
33
56
33
2
TC8-TC8+
+V24 x
U1-U16
TC6+
TC7+
TC5+
TC4+
TC2+
TC3+
TC1+
I+
U4
U6
U8
U7
U5
U3
U2
U1
TC6-
TC7-
TC5-
TC4-
TC2-
TC3-
TC1-
I-
U12
U14
U16
U15
U13
U11
U10
GND
U9
Yellow LED POWER
Green LED U1
Green LED U2
Green LED U3
Green LED U4
Green LED U5
Green LED U6
Green LED U7
Green LED U8
Green LED U9
Green LED U10
Green LED U11
Green LED U12
Green LED U13
Green LED U14
Green LED U15
Green LED U16
Green LED digital input
Green LED run
Red LED Alarm
5 • CONNECTIONS
GEFRAN spa via Sebina, 74 - 25050 Provaglio d’Iseo (BS) Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.com
480131D_MHW_R-TC8_1109_ENG
90
12
-
24V
+
19
20
Proximity
2 wires
PNP
Proximity
3 wires
NPN
Proximity
2 wires
NPN
Proximity
3 wires
PNP
I+
I-
-
+
90
12
22
34
22
56
22
78
22
90
23
12
33
34
33
56
33
-
+
+
-
+
-
-
+
+
-
-
+
-
+
+
-
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
29
30
29
30
29
30
31
32
31
32
33
34
35
36
33
34
35
36
33
34
21
22
-
+
-
+
-
+
-
+
-
+
-
+
-
+
23
24
25
26
27
28
29
30
31
32
33
34
35
36
TC3+
TC2+
TC2-
TC4+
TC4-
TC5-
TC6+
TC6-
TC5+
TC7-
TC7+
TC8+
TC8-
TC3-
TC type:
J, K, N, R, S, E, L, T
RTD PT100
4 wires
TC1+
TC1-
RTD PT100
3 wires
RTD PT100
2 wires
0...50mV
0...2V
3
5
7
9
11
13
15
17
1
3
5
7
4
6
8
90
1
12
11
34
11
56
11
78
11
2
-
+
1 2
24Vcc
+/-25
4
6
8
10
12
14
16
18
2
2
U7
U8
LOAD
LOAD
U2
U4
U5
U3
U1
U6
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
+V24 GND
U9
U10
U11
U13
U12
U15
U16
GND
U14
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
GND
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

gefran R-TC8 Operating instructions

Type
Operating instructions

The gefran R-TC8 is an 8-channel temperature input module with 16 optically isolated digital outputs. It can accept inputs from thermocouples, RTDs, and voltage sources. The module can be configured via software to suit a variety of applications, including temperature monitoring and control. The R-TC8 is ideal for use in industrial environments, such as factories and warehouses. It is also suitable for use in food and beverage processing, as well as in the pharmaceutical industry. Some of its features are:

  • Easy installation and configuration
  • High accuracy and reliability
  • Wide range of input types

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI