3
F-18971 H600/P660/L800 Bowl Lock Kit
Continue Installation Instructions
Installation Instructions Continued
4. The lock solenoid is a dual voltage solenoid and should be wired to match
the motor contactor coil voltage. Attach the appropriate jumpers to the lock
solenoid coil.
5. Determine the form number of the wiring diagram present on the mixer.
A. Read F-18874 and determine which supplemental wiring diagram
matches the wiring diagram form number on mixer.
B. Peel off the proper supplemental wiring diagram and place next to the
original wiring diagram.
6A. On units that have a contactor and separate overload relay, connect solenoid
wire marked 1FB-P2 to fuse board (unit with transformer) or to CON-L2 (unit
without transformer).
B. On units that have a combination starter and overload (Arrow Hart)
remove terminal from wire 1FB-P2 and strip back 1⁄4".
(1) Crimp ring terminal on wire and install at C9 on contactor.
7. Route solenoid wire marked 2PB-NC to the hole at the top of the right hand
side of transmission case (facing attachment hub) passing it through the
existing P clamps.
A. Push the wire through hole into the switch cavity.
8. Free the switch plate assembly from transmission case.
9. Find new solenoid wire marked 2PB-NC in switch cavity and connect to N.C.
contact on new start switch from kit.
A. Disconnect wire(s) marked 2PB-NO from old start switch and connect
to COM. contact on the new start switch.
B. Disconnect wire(s) marked 2PB-C from old start switch and connect to
N.O. contact on the new start switch.
Visual check: Wire from “STOP” switch should go to N.O. contact on new start
switch.
10. Remove start switch boot and old start switch, discard start switch.
11. Install new start switch and switch boot.
12. Reinstall switch plate assembly.
NOTE: Secure the solenoid wires away from any moving parts.