LEDIMPORTANTSAFETYINSTRUCTIONS
Toreducetheriskofdeath,personalinjuryorpropertydamagefromfire,electricshock,fallingparts,cuts/abrasions,and
otherhazardspleasereadallwarningsandinstructionsincludedwithandonthefixtureboxandallfixturelabels.
Beforeinstalling,servicing,orperformingroutinemaintenanceupon
thisequipment,followthesegeneralprecautions.
Installationandserviceofluminairesshouldbeperformedbyaqualifiedlicensedelectrician.
Maintenanceoftheluminairesshouldbeperformedbyperson(s)familiarwiththeluminaires’constructionandoperation
andanyhazardsinvolved.Regularfixturemaintenanceprogramsarerecommended.
Itwill
occasionallybenecessarytocleantheoutsideoftherefractor/lens.Frequencyofcleaningwilldependonambient
dirtlevelandminimumlightoutputwhichisacceptabletouser.Refractor/lensshouldbewashedinasolutionofwarm
waterandanymild,nonabrasivehouseholddetergent,rinsedwithcleanwaterandwiped
dry.Shouldopticalassembly
becomedirtyontheinside,wiperefractor/lensandcleaninabovemanner,replacingdamagedgasketsasnecessary.
DONOTINSTALLDAMAGEDPRODUCT!Thisluminairehasbeenproperlypackedsothatnopartsshouldhavebeen
damagedduringtransit.Inspecttoconfirm.Anypartdamagedor
brokenduringorafterassemblyshouldbereplaced.
Recycle:ForinformationonhowtorecycleLEDelectronicproducts,pleasevisitwww.epa.gov
.
Theseinstructionsdonotpurporttocoveralldetailsorvariationsinequipmentnortoprovideeverypossiblecontingency
tomeetinconnectionwithinstallation,operation,ormaintenance.Shouldfurtherinformationbedesiredorshould
particularproblemsarisewhicharenotcoveredsufficientlyforthepurchaser’sorowner’spurposes,
thismattershouldbe
referredtoAcuityBrandsLighting,Inc.
READANDFOLLOWALLSAFETYINSTRUCTIONS!
SAVETHESEINSTRUCTIONSANDDELIVERTOOWNERAFTERINSTALLATION
Disconnectorturnoffpowerbefore
installationorservicing.
Verifythatsupplyvoltageiscorrectby
comparingitwiththeluminairelabel
information.
Makeallelectricalandgrounded
connectionsinaccordancewiththeNational
ElectricalCode(NEC)andanyapplicable
localcoderequirements.
Allwiringconnections
shouldbecapped
withULapprovedrecognizedwire
connectors.
WARNING
RISKOFELECTRICSHOCK
Allowlamp/fixturetocoolbeforehandling.
Donottouchenclosureorlightsource.
Donotexceedmaximumwattagemar kedon
luminairelabel.
Followallmanufacturer’swarnings,
recommendationsandrestrictionsfor:driver
type,burningposition,mounting
locations/methods,replacementand
recycling.
WARNING
RISKOFBURN
Wearglovesandsafetyglassesatalltimes
whenremovingluminairefromcarton,
installing,servicingorperforming
maintenance.
Avoiddirecteyeexposuretothelightsource
whileitison.
CAUTION
RISKOFINJURY
Keepcombustibleandothermaterialsthat
canburn,awayfromlamp/lens.
Donotoperateincloseproximitytopersons,
combustiblematerialsorsubstances
affectedbyheatordrying.
CAUTION
RISK OF FIRE
Page2of4
LEDIMPORTANTSAFETYINSTRUCTIONS
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory
statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.
OurBrands Indoor/Outdoor IndoorLighting OutdoorLighting Controls Daylighting
LithoniaLighting Gotham AmericanElectricLighting DARKTOLIGHT SunOptics
Carandini MarkArchitecturalLighting AntiqueStreetLamps LC&D
Holophane Peerless Hydrel ROAM
RELOC RenaissanceLighting Tersen SensorSwitch
LightConcepts WinonaLightingSynergy
AcuityBrandsLighting,Inc.assumesnoresponsibilityforclaimsarisingoutofimproperorcarelessinstallationorhandlingofitsproducts.
ABLLEDGeneralWarnings,FormNo.503.203
©2010AcuityBrandsLighting,Inc.Allrightsreserved.12/01/10
Neverconnectcomponentsunderload.
Donotmountorsupportthesefixturesinamannerthatcancuttheouterjacketordamagewire
insulation.
Unlessindividualproductspecificationsdeemotherwise:NeverconnectanLEDproductdirectlytoa
dimmerpacks,occupancysensors,timingdevices,orother
relatedcontroldevices.LEDfixturesmustbe
powereddirectlyoffaswitchedcircuit.
Unlessindividualproductspecificationsdeemotherwise:Donotrestrictfixtureventilation. Allowfor
somevolumeofairspacearoundfixture.AvoidcoveringLEDfixtureswithinsulation,foam,orother
materialthatwillpreventconvectionorconductioncooling.
Unlessindividualproductspecificationsdeemotherwise:Donotexceedfixturesmaximumambient
temperature.
Onlyusefixtureinitsintendedlocation.
LEDproductsarePolaritySensitive.EnsureproperPolaritybefore installation.
ElectrostaticDischarge(ESD):ESDcandamageLEDfixtures.Personalgroundingequipmentmustbe
wornduringallinstallation
orservicingoftheunit.
DonottouchindividualelectricalcomponentsasthiscancauseESD,shortenlamplife,oralter
performance.
Somecomponentsinsidethefixturemaynotbeserviceable.Intheunlikelyeventyourunitmayrequire
service,stopusingtheunitimmediately andcontactan
ABLrepresentativeforassistance.
Alwaysreadthefixturescompleteinstallationinstructionspriortoinstallationforanyadditionalfixture
specificwarnings.
CAUTION:RISKOFPRODUCTDAMAGE
Page3of4
LEDIMPORTANTSAFETYINSTRUCTIONS
SECTION1:INSTALLATIONIBHLED2FTlengthshown(Note:currentIBHLEDisonlysetupforcommercialuse)
1) Disconnectallpowertotheexistingluminaireandremovetheexistingluminairefromtheceiling.Inspecttheexisting
mountinglocationfordamagebeforeinstallthenewIBHLEDhighbayinthis
location.
2) RemovethenewLEDfixturefrompackagingandinspectforanydamages.HandlenewLEDfixturewithcare.Ifdamageddo
notuse;callyourlocalrepforreplacement.
3) CHAINMOUNTEXAMPLE;Installthechainintotheprovidedwirehanger.Securetheotherendofthechain
toastructure
usinghardwareratedfortheload.InstallthewirehangerontothesideofthetopIBHLEDchannel.Contactfactoryor
agencyconcerningareasthathavehighvibration,oroverheadcranesand/orhighvelocity.SEEFIGURE1.
Makesurethewiringhangersarefullyengagedintothesideholesonthetopchannel.Ifusing"S"hooks,makesure
allloopsarecrimpedclosed.
4) ConnecttheLEDhighbaywiringtolinewire,blacktoblack,whitetowhiteandgreentogreen.UseonlyUL
listedwiring
connectors105C(orgreater)andULlistedwiring(105Corgreater).UseonlyULlistedcords.
**NOTE:Purpleandgrayleadinsidethedrivercompartmentare010V(lowvoltage)dimmingleads.Connecttodimming
lowvoltagewiringonly.
5) Cleanallresidues/fingerprintsfromthenewLEDhigh
bayandlens.Doublecheckallhanginghardwarebeforemovingonto
thenextinstallation.
SECTION2:SERVICINGIBH12LSHOWN
1) DisconnectallpowertotheIBHhighbaybeingservice.
2) Toaccessthedriver
,removethetwoscrewsattheendsoppositethesafetycableside.
3) Rotatetopdriverhousingtoitssideandremovethetwoscrewsholdingthechannelcover.FIGURE2A.
4) Rotatetheledhousingtoitsside(ifhangingbythetopchannel).SEEFIGURE2B.
5) Slide
thechannelcoveroffitssecuringclips.SEEFIGURE2.
6) Installnewdriverifneededinthesamelocation.Makesurethenewdriverhassameelectricalspecificationsastheold
driver.Markallwiringbeforeremovetheolddriver.
7) MakesuretoinstalltheEMIferritecore
ontothepowerleadsofthenewdriver.Ifpresentinyourassembly.
8) UseonlyULlistedcomponents,wiringandconnectors.
9) Whenserviceisdone,makesuretopushallledwiringbackintothedriverhousingbeforerotatingthedriverhousingto
closedposition.SEEFIGURE2Aand
FIGURE2B.Donotletwiringgetcaughtoutsidethetwoassemblies.
10) Tocleanlens
,removeonebottomendcoverandslidelensout.NOTE:LEDhousingismadefromaluminumsheets.Donot
overtightenscrewswhenreinstallingtheendcover.UsehandheldscrewdriverONLYtoremoveandinstallscrews.
11) Slidelensoutslowlyandcleanbothsidesof
lens.Cleanlenswillensureoptimallightoutput.SEEFIGURE3.
12) Reinstallthelensandendcoverwhencleaningisdone.Glosssideoflensfacesfloor
.
13) Maintenanceoftheluminairesshouldbeperformedbyperson(s)familiarwiththeluminaires’constructionandoperationand
anyhazardsinvolved.Regularfixturemaintenanceprogramsarerecommendedforoptimallightoutput.
Page4of4
LEDIMPORTANTSAFETYINSTRUCTIONS
Fiveyearlimitedwarranty.Warrantytermsarelocatedat(U459430REVF)
www.acuitybrands.com/customerresources/term_and_conditions.aspx