Hewlett Packard Enterprise JG898A Datasheet

Category
Network switches
Type
Datasheet

This manual is also suitable for

Key features
•Highperformanceportexpansionwithtruelocalswitchingcapacity
•HPIntelligentResilientFabric(IRF)forvirtualizationandtwo-tiernetworks
•High1/10GbEwirespeedportswith40GbEuplinks
•Layer2andlightLayer3featureswithstaticroutingandRIP
•ConvergencereadywithDCB,FCoE,andTRILL
Product overview
TheHPFlexFabric5700SwitchSeriesisafamilyofhigh-performance,Lowlatency,access
switchesaimedatexpandingportconnectivitywhileaddinglocalswitchingcapacity.Thatis
partoftheHPFlexNetworkarchitecture’sHPFlexFabricsolution.
Ideallysuitedfordeploymentattheserveraccesslayeroflargeandmediumsizedenterprise
datacenters.TheHPFlexFabric5700SwitchSeriesdeliverslowerTCOwhileenhancing
networkingperformancetosupportdemandingvirtualizedapplicationsandserver-to-server
traic.Resilienceandeaseofmanagementcomehand–in-handwiththeFlexFabric5700.
WhileIRFreducesmanagementcomplexitiesbyupto88%,italsodeliversagilitywith<50msec
convergencetime.
Data sheet
HP FlexFabric 5700 Switch
Series
2
Datasheet|HPFlexFabric5700SwitchSeries
Features and benets
Quality of service (QoS)
•PowerfulQoSfeatures
Flexibleclassication
FlowclassicationbasedonsourceMAC,destinationMAC,sourceIP(IPv4/IPv6),destination
IP,port,protocol,andVLAN
Featurequeuescheduling
Providessupportforstrictpriority(SP),weighteddecitroundrobin(WDRR),weightedfair
queuing(WFQ),SP+WDRR,andSP+WFQ.SupportsExplicitCongestionNotication(ECN)and
weightedrandomearlydetection(WRED)
Data center-optimized
•Versatileserverconnectivity
TheHPFlexFabric5700SwitchSeriesenablesscalingoftheserveredgewith1GbEand10GbE
ToRdeploymentstonewheightswithhigh-density32-and48-portsolutionsdeliveredina
1RUformfactor.TheFlexFabric5700switchescanbesetupasstandalonelayer2andlite
layer3switches.TheycanalsobesetuptobeautomaticallyconguredasleafswitchesinPort
Extenders(PE)modewhenconnectedtoControllingBridge(CB)switchessuchasFlexFabric
5900switches,FlexFabric11900switchesorFlexFabric12900switches.(future)TheFlexFabric
5700serieshigh-serverportdensityisbackedby40GbEQSFP+uplinkstodelivertheavailability
ofneededbandwidthfordemandingapplications.Each40GbEQSFP+portcanalsobe
conguredasfour10GbEportsbyusinga40GbE-to-10GbEsplittercable
•High-performanceswitching
Cut-throughandnon-blockingarchitecturedeliverslowlatency(~1.5microsecondfor10GbE)
forverydemandingenterpriseapplications.TheFlexFabric5700switchesalsodeliver
high-performanceswitchingcapacityandwire-speedpacketforwarding.Thelocalswitching
capacityandpacketforwardingenabletheFlexFabric5700seriestoparticipateinthenetwork
andenhancenetworkingcapacityavailableforservers.Thisisincontrasttocompetingport
extendersthatoernolocalswitchingcapacity.
•Higherscalabilityandsimpliedmanagement
HPIRFtechnologysimpliesthearchitectureofserveraccessnetworks;uptonineHP
FlexFabric5700physicalswitchescanbecombinedintoonevirtualswitchconguration
andaremanagedusingasingleIPaddress.IRFenablestheFlexFabric5700seriestodeliver
unmatchedscalabilityofvirtualizedswitchesandattertwo-tiernetworks,whichreduces
costandcomplexity.Inaddition,supportforIRFfabricenhancementswillenableupto30
FlexFabric5700seriesswitchestobemanagedasonevirtualswitchwhenconguredasPEs
usingtheFlexFabric5900switchactingasaControllingBridge(future).
•Advancedmodularnetworkoperatingsystem
HPComwarev7networkoperatingsystem’smodulardesignandmultipleprocessesbring
nativehighstability,independentprocessmonitoring,andarestart;theOSalsoallows
individualsoftwaremodulestobeupgradedforhigheravailabilityandsupportsenhanced
serviceabilityfunctionslikehitlesssoftwareupgradeswithsingle-chassisInServiceSoftware
Upgrade(ISSU)
•TRILLandEVBandVEPA
TRansparentInterconnectionofLotsofLinks(TRILL)issupportedtoincreasethescaleof
enterprisedatacenters;EdgeVirtualBridgingwithVirtualEthernetPortAggregator(EVB/
VEPA)providesconnectivityintothevirtualenvironmentforadatacenter-readyenvironment
3
•Reversibleairow
Enhancedfordatacenterhot-coldaisledeploymentwithreversibleairow—foreitherfront-
to-backorback-to-frontairow
•Redundantfansandpowersupplies
1+1internalredundantandhot-pluggablepowersuppliesanddualfantraysenhance
reliabilityandavailability
•LowerOPEXandgreenerdatacenter
Providereversibleairowandadvancedchassispowermanagementforlowerpower
consumption
•DataCenterBridging(DCB)protocols
ProvidessupportforIEEE802.1QbbPriorityFlowControl(PFC)andDataCenterBridging
Exchange(DCBX)forconvergedapplications
•FCoEsupport
ProvidessupportforFibreChanneloverEthernet(FCoE)includingFibreChannelForwarder
(FCF),transit,andN-PortVirtualization(NPV)
•Jumboframes
Framesizesofupto10,000bytesonGigabitEthernetand10Gigabitportsallowshigh-
performanceremotebackupanddisaster-recoveryservicestobeenabled
Manageability
•Fullyfeaturedconsole
ProvidescompletecontroloftheswitchwithafamiliarCommandLineInterface(CLI)
•Troubleshooting
Ingressandegressportmonitoring
Enablenetworkproblemsolving
Tracerouteandping
Enabletestingofnetworkconnectivity
•Multiplecongurationles
Allowmultiplecongurationlestobestoredtoaashimage
•sFlow(RFC3176)
Provideswire-speedtraicaccountingandmonitoring
•SNMPv1,v2c,andv3
Facilitatecentralizeddiscovery,monitoring,andsafermanagementofnetworkingdevices
•Out-of-bandinterface
Isolatesmanagementtraicfromuserdataplanetraicforcompleteisolationandtotal
reachability,nomatterwhathappensinthedataplane
•Remotecongurationandmanagement
Isavailablethroughasecurecommand-lineinterface(CLI)overTelnetandSSH;Role-Based
AccessControl(RBAC)providesmultiplelevelsofaccess;congurationrollbackandmultiple
congurationsontheashprovideeaseofoperation;remotevisibilityisprovidedwithsFlow
andSNMPv1/v2/v3,andisfullysupportedinHPIntelligentManagementCenter(IMC)
Datasheet|HPFlexFabric5700SwitchSeries
4
•ISSUandhotpatching
Providehitlesssoftwareupgradeswithsingle-unitISSUandhitlesspatchingofthemodular
operatingsystem
•Auto-conguration
ProvidesautomaticcongurationviaDHCPauto-conguration,NETCONF,andPythonscripting
•NetworkTimeProtocol(NTP)andSecureNetworkTimeProtocol(SNTP)
Synchronizetimekeepingamongdistributedtimeserversandclients;keepconsistent
timekeepingamongallclock-dependentdeviceswithinthenetworksothatthedevicescan
providediverseapplicationsbasedontheconsistenttime.PrecisionTimeProtocol(PTP)RFC
1855-compliant
Resiliency and high availability
•HPIntelligentResilientFabric(IRF)technology
EnablesanHPFlexFabrictodeliverresilient,scalable,andsecureddatacenternetworksfor
physicalandvirtualizedenvironments;groupsuptonineHPFlexFabric5700switchesinan
IRFconguration,allowingthemtobeconguredandmanagedasasinglevirtualswitchwith
asingleIPaddress;simpliesToRandspine/leafdeploymentsandmanagement,reducing
datacenterdeploymentandoperatingexpenses
•IEEE802.1wRapidConvergenceSpanningTreeProtocol
Increasesnetworkuptimethroughfasterrecoveryfromfailedlinks
•IEEE802.1sMultipleSpanningTreeProtocol(MSTP)
ProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingMultipleSpanning
Trees
•Hitlesspatchupgrades
Allowspatchesandnewservicefeaturestobeinstalledwithoutrestartingtheequipment,
increasingnetworkuptimeandfacilitatingmaintenance
•DeviceLinkDetectionProtocol(DLDP)
Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltraicis
detected,preventingloopsinSTP-basednetworks
Layer 2 switching
•AddressResolutionProtocol(ARP)
Supportsstatic,dynamic,andreverseARPandARPproxy
•FlowControl
IEEE802.3xFlowControlprovidesintelligentcongestionmanagementviaPAUSEframes
•Ethernetlinkaggregation
ProvidesIEEE802.3adLinkAggregationofupto128groupsof16ports;supportforLACP,
LACPLocalForwardingFirst,andLACPShort-timeprovidesafast,resilientenvironmentthatis
idealforthedatacenter
•SpanningTreeProtocol(STP)
STP(IEEE802.1D),RapidSTP(RSTP,IEEE802.1w),andMultipleSTP(MSTP)(IEEE802.1s)
Datasheet|HPFlexFabric5700SwitchSeries
5
•VLANsupport
Providessupportfor4,094VLANsbasedonport.VLANmapping,QinQ,andSelectiveQinQ
•IGMPsupport
ProvidessupportforIGMPsnoopingv1/v2/v3,PIMsnooping,MLDsnoopingv1/v2,andIPv6
PIMsnooping
•DHCPsupportatLayer2
ProvidesfullDHCPsnoopingsupportforDHCPSnoopingOption82,DHCPRelayOption82,
DHCPSnoopingTrust,andDHCPSnoopingItemBackup
Layer 3 services
•AddressResolutionProtocol(ARP)
DeterminestheMACaddressofanotherIPhostinthesamesubnet;supportsstaticARPs;
gratuitousARPallowsdetectionofduplicateIPaddresses;proxyARPallowsnormalARP
operationbetweensubnetsorwhensubnetsareseparatedbyaLayer2network
•DynamicHostCongurationProtocol(DHCP)
SimpliesthemanagementoflargeIPnetworksandsupportsclientandserver;DHCPRelay
enablesDHCPoperationacrosssubnets
•Operations,administration,andmaintenance(OAM)support
ProvidessupportforConnectivityFaultManagement(IEEE802.1AG)andEthernetintheFirst
Mile(IEEE802.3AH);providesadditionalmonitoringthatcanbeusedforfastfaultdetection
andrecovery
Layer 3 routing
•Equal-CostMultipath(ECMP)
Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyand
scalebandwidth
•Layer3IPv4routing
ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIP,andRIPv2
•StaticIPv6routing
ProvidessimplemanuallyconguredIPv6routing
•DualIPstack
MaintainsseparatestacksforIPv4andIPv6toeasethetransitionfromanIPv4-onlynetwork
toanIPv6-onlynetworkdesign
•BidirectionalForwardingDetection(BFD)
EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,
BGP,IS-IS,VRRP,MPLS,andIRF
•Layer3IPv6routing
ProvidesroutingofIPv6atmediaspeed;supportsstaticroutingandRIPng
Additional information
•GreenITandpower
Improvesenergyeiciencythroughtheuseofthelatestadvancesinsilicondevelopment;
shutsounusedportsandutilizesvariablespeedfans,reducingenergycosts
•Lowpowerconsumption
IsratedtohaveoneofthelowestpowerusagesintheindustrybyMiercomindependenttests
Datasheet|HPFlexFabric5700SwitchSeries
6
Management
•USBsupport
Filecopy
AllowsuserstocopyswitchlestoandfromaUSBashdrive
•Multiplecongurationles
Storeeasilytotheashimage
•NetworkTimeProtocol(NTP)
Synchronizestimekeepingamongdistributedtimeserversandclients;keepstimekeeping
consistentamongallclock-dependentdeviceswithinthenetworksothatthedevicescan
providediverseapplicationsbasedontheconsistenttime
•Portmirroring
Enablestraiconaporttobesimultaneouslysenttoanetworkanalyzerformonitoring
•Remotecongurationandmanagement
Isavailablethroughacommand-lineinterface(CLI)
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,
facilitatingeasymappingbynetworkmanagementapplications
•sFlow(RFC3176)
ProvidesscalableASIC-basedwire-speednetworkmonitoringandaccountingwithnoimpact
onnetworkperformance;thisallowsnetworkoperatorstogatheravarietyofsophisticated
networkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoring
purposes
•Commandauthorization
LeveragesRADIUStolinkacustomlistofCLIcommandstoanindividualnetwork
administrator’slogin;anaudittraildocumentsactivity
•Dualashimages
Provideindependentprimaryandsecondaryoperatingsystemlesforbackupwhile
upgrading
•Command-lineinterface(CLI)
Providesasafe,easy-to-useCLIforconguringthemoduleviaSSHoraswitchconsole;
providesdirectreal-timesessionvisibility
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslog
throttlingandloglteringtoreducethenumberoflogeventsgenerated
•Managementinterfacecontrol
Providesmanagementaccessthroughamodemportandterminalinterface,aswellasin-
bandandout-of-bandEthernetports;providesaccessthroughterminalinterface,Telnet,or
secureshell(SSH)
•Industry-standardCLIwithahierarchicalstructure
Reducestrainingtimeandexpenses,andincreasesproductivityinmultivendorinstallations
•Managementsecurity
Restrictsaccesstocriticalcongurationcommands;oersmultipleprivilegelevelswith
passwordprotection;ACLsprovideTelnetandSNMPaccess;localandremotesyslog
capabilitiesallowloggingofallaccess
Datasheet|HPFlexFabric5700SwitchSeries
7
•Informationcenter
Providesacentralrepositoryforsystemandnetworkinformation;aggregatesalllogs,traps,
anddebugginginformationgeneratedbythesystemandmaintainstheminorderofseverity;
outputsthenetworkinformationtomultiplechannelsbasedonuser-denedrules
•Networkmanagement
HPIntelligentManagementCenter(IMC)centrallycongures,updates,monitors,and
troubleshoots
•Remoteintelligentmirroring
Mirrorsingress/egressACL-selectedtraicfromaswitchportorVLANtoalocalorremote
switchportanywhereonthenetwork
Security
•Accesscontrollists(ACLs)
ProvideIPLayer3lteringbasedonsource/destinationIPaddress/subnet,andsource/
destinationTCP/UDPportnumber
•RADIUS/TACACS+
Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver
•Secureshell
EncryptsalltransmitteddataforsaferemoteCLIaccessoverIPnetworks
•IEEE802.1XandRADIUSnetworklogins
Controlsport-basedaccessforauthenticationandaccountability
•Portsecurity
AllowsaccessonlytospeciedMACaddresses,whichcanbelearnedorspeciedbythe
administrator
Convergence
•LLDP-MED(MediaEndpointDiscovery)
DenesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLAN
toautomaticallycongurenetworkdevicessuchasIPphones
Warranty and support
•1-yearwarranty
Advancehardwarereplacementwith10-calendar-daydelivery(availableinmostcountries)
•Electronicandtelephonesupport
Limitedelectronicandbusiness-hourstelephonesupportisavailablefromHPfortheentire
warrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;
fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/
networking/warrantysummary
•Softwarereleases
Tondsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthe
softwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/
warrantysummary
Datasheet|HPFlexFabric5700SwitchSeries
8
HP FlexFabric 5700 Switch Series
Specications
HP FlexFabric 5700-40XG-2QSFP+
Switch (JG896A)
HP FlexFabric 5700-48G-4XG-2QSFP+
Switch (JG894A)
HP FlexFabric 5700-32XGT-8XG-
2QSFP+ Switch (JG898A)
I/O ports and slots 40xed1000/10000SFP+ports
2QSFP+
48RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
4xed1000/10000SFP+ports
2QSFP+
32RJ-451/10GBASE-Tports;Duplex:
100BASE-TX/1000BASE-TX/10GBASE-TX:
FullOnly
8xed1000/10000SFP+ports
2QSFP+
Additional ports and slots 1RJ-45serialconsoleport
1RJ-45out-of-bandmanagementport
1USB2.0
1RJ-45serialconsoleport
1RJ-45out-of-bandmanagementport
1USB2.0
1RJ-45serialconsoleport
1RJ-45out-of-bandmanagementport
1USB2.0
Power supplies 2powersupplyslots
1minimumpowersupplyrequired
(orderedseparately)
2powersupplyslots
1minimumpowersupplyrequired
(orderedseparately)
2powersupplyslots
1minimumpowersupplyrequired
(orderedseparately)
Fan tray 2fantrayslots
Thecustomermustorderfantrays,
asfantraysarenotincludedwiththe
switch.Thissystemrequirestwosame-
directionairowfantraystofunction
properly.Thesystemshouldnotbe
operatedwithonlyonefantrayfor
morethan24hours.Thesystemshould
notbeoperatedwithoutafantrayfor
morethantwominutes.Thesystem
shouldnotbeoperatedoutsideofthe
temperaturerangeof32°F(0°C)to113°F
(45°C).Failuretocomplywiththese
operatingrequirementsmayvoidthe
productwarranty.
2fantrayslots
Thecustomermustorderfantrays,
asfantraysarenotincludedwiththe
switch.Thissystemrequirestwosame-
directionairowfantraystofunction
properly.Thesystemshouldnotbe
operatedwithonlyonefantrayfor
morethan24hours.Thesystemshould
notbeoperatedwithoutafantrayfor
morethantwominutes.Thesystem
shouldnotbeoperatedoutsideofthe
temperaturerangeof32°F(0°C)to113°F
(45°C).Failuretocomplywiththese
operatingrequirementsmayvoidthe
productwarranty.
2fantrayslots
Thecustomermustorderfantrays,
asfantraysarenotincludedwiththe
switch.Thissystemrequirestwosame-
directionairowfantraystofunction
properly.Thesystemshouldnotbe
operatedwithonlyonefantrayfor
morethan24hours.Thesystemshould
notbeoperatedwithoutafantrayfor
morethantwominutes.Thesystem
shouldnotbeoperatedoutsideofthe
temperaturerangeof32°F(0°C)to
11F(45°C).Failuretocomplywith
theseoperatingrequirementsmayvoid
theproductwarranty.
Physical characteristics
Dimensions
Weight
17.32(w)x18.11(d)x1.72(h)in,(43.99x
46x4.37cm)(1Uheight)
22.05lb(10kg)shippingweight
17.32(w)x18.11(d)x1.72(h)in,(43.99x
46x4.37cm)(1Uheight)
22.05lb(10kg)shippingweight
17.32(w)x25.98(d)x1.72(h)in,(43.99x
46x4.37cm)(1Uheight)
28.66lb(13kg)shippingweight
Memory and processor 512MBash,2GBSDRAM;packetbuer
size:9MB
512MBash,2GBSDRAM;packetbuer
size:9MB
512MBash,2GBSDRAM;packetbuer
size:9MB
Performance
10Gb/sLatency
Throughput
Routing/Switchingcapacity
Routingtablesize
MACaddresstablesize
<1.5µs(64-bytepackets)
714.2Mpps
960Gb/s
128entries(IPv4),128entries(IPv6)
128000entries
<5µs(64-bytepackets)
250Mpps
336Gb/s
128entries(IPv4),128entries(IPv6)
128000entries
<1.5µs(64-bytepackets)
714.2Mpps
960Gb/s
128entries(IPv4),128entries(IPv6)
128000entries
Datasheet|HPFlexFabric5700SwitchSeries
9
Environment
Operatingtemperature
Operatingrelativehumidity
Acoustic
32°Fto113°F(Cto45°C)
10%to90%,noncondensing
Low-speedfan:65.7dB,High-speedfan:
70.6dB
32°Fto113°F(Cto45°C)
10%to90%,noncondensing
Low-speedfan:65.7dB,High-speedfan:
70.6dB
32°Fto113°F(Cto45°C)
10%to90%,noncondensing
Low-speedfan:65.7dB,High-speedfan:
70.6dB
Electrical characteristics
Frequency
ACvoltage
DCvoltage
Maximumpowerrating
Idlepower
50/60Hz
100-240VAC
-48to-60VDC
162W
90W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximum
heatdissipationaretheworst-case
theoreticalmaximumnumbersprovided
forplanningtheinfrastructurewithfully
loadedPoE(ifequipped),100%traic,
allportspluggedin,andallmodules
populated.
50/60Hz
100-240VAC
-48to-60VDC
175W
115W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximum
heatdissipationaretheworst-case
theoreticalmaximumnumbersprovided
forplanningtheinfrastructurewithfully
loadedPoE(ifequipped),100%traic,
allportspluggedin,andallmodules
populated.
50/60Hz
100-240VAC
-48to-60VDC
350W
150W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximum
heatdissipationaretheworst-case
theoreticalmaximumnumbersprovided
forplanningtheinfrastructurewithfully
loadedPoE(ifequipped),100%traic,
allportspluggedin,andallmodules
populated.
Safety UL60950-1;EN60825-1Safetyof
LaserProducts-Part1;EN60825-2
SafetyofLaserProducts-Part2;IEC
60950-1;CAN/CSA-C22.2No.60950-1;
Anatel;ULAR;GOST;EN60950-1/A11;
FDA21CFRSubchapterJ;NOM;ROHS
Compliance
UL60950-1;EN60825-1Safetyof
LaserProducts-Part1;EN60825-2
SafetyofLaserProducts-Part2;IEC
60950-1;CAN/CSA-C22.2No.60950-1;
Anatel;ULAR;GOST;EN60950-1/A11;
FDA21CFRSubchapterJ;NOM;ROHS
Compliance
UL60950-1;EN60825-1Safetyof
LaserProducts-Part1;EN60825-2
SafetyofLaserProducts-Part2;IEC
60950-1;CAN/CSA-C22.2No.60950-1;
Anatel;ULAR;GOST;EN60950-1/A11;
FDA21CFRSubchapterJ;NOM;ROHS
Compliance
Emissions VCCIClassA;EN55022ClassA;ICES-003
ClassA;ANSIC63.42003;AS/NZSCISPR
22ClassA;EN61000-3-2:2006;EN
61000-3-3:1995+A1:2001+A2:2005;
EMCDirective2004/108/EC;FCC(CFR47,
Part15)ClassA
VCCIClassA;EN55022ClassA;ICES-003
ClassA;ANSIC63.42003;AS/NZSCISPR
22ClassA;EN61000-3-2:2006;EN
61000-3-3:1995+A1:2001+A2:2005;
EMCDirective2004/108/EC;FCC(CFR47,
Part15)ClassA
VCCIClassA;EN55022ClassA;ICES-003
ClassA;ANSIC63.42003;AS/NZSCISPR
22ClassA;EN61000-3-2:2006;EN
61000-3-3:1995+A1:2001+A2:2005;
EMCDirective2004/108/EC;FCC(CFR47,
Part15)ClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMCIntelligentManagementCenter;
command-lineinterface;out-of-band
management;SNMPManager;Telnet;FTP
IMCIntelligentManagementCenter;
command-lineinterface;out-of-band
management;SNMPManager;Telnet;FTP
IMCIntelligentManagementCenter;
command-lineinterface;out-of-band
management;SNMPManager;Telnet;FTP
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservices
andresponsetimesinyourarea,please
contactyourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservices
andresponsetimesinyourarea,please
contactyourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservices
andresponsetimesinyourarea,please
contactyourlocalHPsalesoice.
Datasheet|HPFlexFabric5700SwitchSeries
10
Standards and Protocols
(appliestoallproductsinseries)
Device management RFC1157SNMPv1/v2c
RFC1305NTPv3
RFC1591DNS(client)
RFC1902(SNMPv2)
RFC1908(SNMPv1/2Coexistence)
RFC2573(SNMPv3Applications)
RFC2576(CoexistencebetweenSNMP
V1,V2,V3)
MultipleCongurationFiles
MultipleSoftwareImages
SSHv1/SSHv2SecureShell
TACACS/TACACS+
General protocols IEEE802.1adQ-in-Q
IEEE802.1agServiceLayerOAM
IEEE802.1DMACBridges
IEEE802.1DSpanningTreeProtocol
IEEE802.1pPriority
IEEE802.1QVLANs
IEEE802.1sMultipleSpanningTrees
IEEE802.1wRapidRecongurationof
SpanningTree
IEEE802.3Type10BASE-T
IEEE802.3ab1000BASE-TGigabit
Ethernetovertwistedpair(10/100/1000
modelsonly)
IEEE802.3adLinkAggregationControl
Protocol(LACP)
IEEE802.3ae10-GigabitEthernet
IEEE802.3agEthernetOAM
IEEE802.3ahEthernetinFirstMileover
PointtoPointFiber-EFMF
IEEE802.3xFlowControl
RFC768UDP
RFC783TFTPProtocol(revision2)
RFC791IP
RFC792ICMP
RFC793TCP
RFC826ARP
RFC854TELNET
RFC856TELNET
RFC868TimeProtocol
RFC896CongestionControlinIP/TCP
Internetworks
RFC950InternetStandardSubnetting
Procedure
RFC1027ProxyARP
RFC1058RIPv1
RFC1091TelnetTerminal-TypeOption
RFC1141Incrementalupdatingofthe
Internetchecksum
RFC1191PathMTUdiscovery
RFC1213ManagementInformationBase
forNetworkManagementofTCP/IP-
basedinternets
RFC1531DynamicHostConguration
Protocol
RFC1541DHCP
RFC1591DNS(clientonly)
RFC1624IncrementalInternetChecksum
RFC1723RIPv2
RFC1812IPv4Routing
RFC2030SimpleNetworkTimeProtocol
(SNTP)v4
RFC2131DHCP
RFC2236IGMPSnooping
RFC2453RIPv2
RFC2581TCPCongestionControl
RFC2644DirectedBroadcastControl
RFC2767DualStacksIPv4&IPv6
RFC3046DHCPRelayAgentInformation
Option
RFC4250TheSecureShell(SSH)
ProtocolAssignedNumbers
RFC4251TheSecureShell(SSH)Protocol
Architecture
RFC4252TheSecureShell(SSH)
AuthenticationProtocol
RFC4253TheSecureShell(SSH)
TransportLayerProtocol
RFC4254TheSecureShell(SSH)
ConnectionProtocol
RFC4419Diie-HellmanGroupExchange
fortheSecureShell(SSH)Transport
LayerProtocol
RFC4594CongurationGuidelinesfor
DiServServiceClasses
RFC4941PrivacyExtensionsfor
StatelessAddressAutocongurationin
IPv6
IPv6 RFC2080RIPngforIPv6
RFC2460IPv6Specication
RFC2461IPv6NeighborDiscovery
RFC2462IPv6StatelessAddressAuto-
conguration
RFC2463ICMPv6
RFC2464TransmissionofIPv6over
EthernetNetworks
RFC2563ICMPv6
RFC2711IPv6RouterAlertOption
RFC2767DualstacksIPv4&IPv6
RFC3315DHCPv6(clientandrelay)
RFC4291IPVersion6Addressing
Architecture
RFC4862IPv6StatelessAddressAuto-
conguration
RFC5095DeprecationofType0Routing
HeadersinIPv6
MIBs RFC1213MIBII
RFC1907SNMPv2MIB
RFC2571SNMPFrameworkMIB
RFC2572SNMP-MPDMIB
RFC2573SNMP-NoticationMIB
RFC2573SNMP-TargetMIB
RFC2574SNMPUSMMIB
RFC2737EntityMIB(Version2)
RFC3414SNMP-Userbased-SMMIB
RFC3415SNMP-Viewbased-ACMMIB
LLDP-EXT-DOT1-MIB
LLDP-EXT-DOT3-MIB
LLDP-MIB
Network management RFC3164BSDsyslogProtocol
QoS/CoS IEEE802.1P(CoS)
RFC2475DiServArchitecture
RFC2597DiServAssuredForwarding
(AF)
RFC3247SupplementalInformation
fortheNewDenitionoftheEFPHB
(ExpeditedForwardingPer-HopBehavior)
RFC3260NewTerminologyand
ClaricationsforDiServ
Security AccessControlLists(ACLs) SSHv2SecureShell
Datasheet|HPFlexFabric5700SwitchSeries
11
HP FlexFabric 5700 Switch Series accessories
Transceivers HPX1201GSFPLCLH401550nmTransceiver(JD062A)
HPX1201GSFPLCBX10-UTransceiver(JD098B)
HPX1201GSFPLCBX10-DTransceiver(JD099B)
HPX1201GSFPLCLXTransceiver(JD119B)
HPX1201GSFPRJ45TTransceiver(JD089B)
HPX1201GSFPLCSXTransceiver(JD118B)
HPX1251GSFPLCLH401310nmTransceiver(JD061A)
HPX1251GSFPLCLH70Transceiver(JD063B)
HPX13010GSFP+LCSRTransceiver(JD092B)
HPX13010GSFP+LCLRMTransceiver(JD093B)
HPX13010GSFP+LCLRTransceiver(JD094B)
HPX13010GSFP+LCER40kmTransceiver(JG234A)
HPX14040GQSFP+MPOSR4Transceiver(JG325A)
HPX24010GSFP+toSFP+0.65mDirectAttachCopperCable(JD095C)
HPX24010GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)
HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)
HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)
HPX24040GQSFP+toQSFP+1mDirectAttachCopperCable(JG326A)
HPX24040GQSFP+toQSFP+3mDirectAttachCopperCable(JG327A)
HPX24040GQSFP+toQSFP+5mDirectAttachCopperCable(JG328A)
HPX24040GQSFP+to4x10GSFP+1mDirectAttachCopperSplitterCable(JG329A)
HPX24040GQSFP+to4x10GSFP+3mDirectAttachCopperSplitterCable(JG330A)
HPX24040GQSFP+to4x10GSFP+5mDirectAttachCopperSplitterCable(JG331A)
HPX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)
HPX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)
HPX14040GQSFP+MPOSR4Transceiver(JG325B)
HPX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)
Datasheet|HPFlexFabric5700SwitchSeries
RatethisdocumentSharewithcolleagues
Sign up for updates
hp.com/go/getupdated
©Copyright2014Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.Theonly
warrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothingherein
shouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.
4AA5-3607ENW,August2014
HP FlexFabric 5700-40XG-2QSFP+ Switch (JG896A) HP58x0AFBack(PowerSide)toFront(PortSide)Airow300WACPowerSupply(JG900A)
HP58x0AFBack(PowerSide)toFront(PortSide)Airow300WDCPowerSupply(JG901A)
HP58x0AFBack(powerside)toFront(portside)AirowFanTray(JC682A)
HP58x0AFFront(portside)toBack(powerside)AirowFanTray(JC683A)
HP FlexFabric 5700-48XG-4XG-2QSFP+ Switch (JG894A) HP58x0AFBack(PowerSide)toFront(PortSide)Airow300WACPowerSupply(JG900A)
HP58x0AFBack(PowerSide)toFront(PortSide)Airow300WDCPowerSupply(JG901A)
HP58x0AFBack(powerside)toFront(portside)AirowFanTray(JC682A)
HP58x0AFFront(portside)toBack(powerside)AirowFanTray(JC683A)
HP FlexFabric 5700-32XGT-8XG-2QSFP+ Switch
(JG898A)
HPX711Front(portside)toBack(powerside)AirowHighVolumeFanTray(JG552A)
HPX712Back(powerside)toFront(portside)AirowHighVolumeFanTray(JG553A)
HP58x0AF650WACPowerSupply(JC680A)
HP58x0AF650WDCPowerSupply(JC681A)
Learn more at
hp.com/networking
Datasheet|HPFlexFabric5700SwitchSeries
HP FlexFabric 5700 Switch Series accessories (continued)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Hewlett Packard Enterprise JG898A Datasheet

Category
Network switches
Type
Datasheet
This manual is also suitable for